Mellerware 3 5 5 3 0 Operation, Setting The Clock, Setting The Power, Using Of Timer

Page 4
OPERATION

OPERATION

1.Before using the heater make sure that it is on a flat and stable surface. Damage may occur if it is placed on an incline or decline.

2.Set all the controls to OFF position, and insert the plug into a socket-outlet that is well grounded. Be sure plug fits tightly into outlet. Be sure that the main power switch is on before operating the control panel.

3.Operation for control panel.

1.) SETTING THE CLOCK

Set the clock to the correct time before using the heater, proceeding as follows:

Press the button “hour” until the display shows the hours for the correct time, then release the button. Press the button “minute” until the display shows the minutes for the correct time, then release the button. Whenever you want ot modify hours or minutes during operation, just proceed as above.

AMMAX

 

 

C

 

Time

Set

 

OFF

Temperature

NOTE: Do not modify the clock while the heater is operating in auto mode. To activate the set time, you must release the button “hour” or “minute” for at least 5 seconds.

2.) SETTING THE POWER

The variable power setting determines how fast the desired temperature is reached. The higher the power setting, the more energy is used.

NOTE:If you want to operate the appliance in manual mode, press the button “power setting” to activate it. In this mode, the function of the booking timer will be invalidated.

To set the required power level, proceed as follows: press the “power setting” button one or more times within 5 seconds to select the power level, as per the following sequence:

AM

 

 

 

 

MAX

 

AM

 

 

MAX

 

 

 

 

 

 

C

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The power selecting can be circulated and the red power pilot light will be on during the heater powered on.

To cancel the manual mode, push the button “power setting” until the LCD appear “OFF”, the red power pilot light will be extinguished. Now the unit can be set in auto mode.

3.) SETTING THE AMBIENT TEMPERATURE

Adjust the “+” or “-“ button to the desired ambient temperature from 5 to 35˚C at any time during operation. By pushing once the “+” or “-“ button

the temperature (shown on the right side of the display) will increase or decrease by 1˚C. Keep the button pressed to move through the temperature in fast mode.

AMMAX

 

 

 

 

 

 

 

C

 

Time

 

 

 

 

 

 

Set

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

This heater has a sensitive temperature detector, which automatically monitors the current ambient temperature and switches the unit on to maintain your chosen temperature.

If the selected temperature is higher than the actual room temperature, the appliance will start automatically and rapidly heat the room until it reaches the selected temperature. The unit will automatically maintain the temperature at a constant level.

4.) USING OF TIMER

The function of the time works only under the setting manual mode setting. After the unit is powered on in the manual mode, press the button “timing” one or more times within 5 seconds to select the timing level, as per the following sequence:

0:00h – 0:30h – 0:45h – 1:00h – 2:00h – 4:00h – 8:00h

The timing setting can be circulated as above sequence and the timing pilot lamp light will be on during the timing function activation. To cancel the timing, push the button “timing” until the LCD appears “0:00h” or push the button “power setting” until the LCD appears “OFF” and wait for 5 seconds, the yellow timing pilot light will go out.

MAXIMUM POWER

AMMAX

1.) SETTING THE CLOCKC

MINIMUM POWER

MEDIUM POWER

AMMAX

2.) SETTING THE POWERC

OFF

OFF

Image 4
Contents IEC60335 3 5 5SAFETY SPECIFICATIONS 2 y e a r g u a r a n t e eIMPORTANT SAFETY GUARDS FOR YOUR SAFETYA B C D E F G H Ambiente 1200 LCD Oil HeaterCOMPULSORY WARNING SAVE THESE INSTRUCTIONS YOUR HEATER COLUMNHEATING MOUNTING THE FEET1. SETTING THE CLOCK 2. SETTING THE POWER3. SETTING THE AMBIENT TEMPERATURE 4. USING OF TIMER5. ANTI-FREEZESETTING 6. USING OF BOOKING TIMERc. Auto a. Auto on