I N T R O D U C T I O N

The GEM-RP1CAe2 is a “smartuser-friendly, menu-driven keypad designed for your Napco GEM-X255 control panel. The keypad is interactive. Its alphanumeric screen will not only display the status of your system, but will also give you step-by-step instructions to guide you through all operations.

This booklet contains important information about the operation of your system with this GEM-RP1CAe2 Keypad. Read it carefully and keep it handy for

future reference. Check the Glossary for an explanation of terms that may be unfamiliar to you.

You'll probably find subjects

mentioned in this booklet that do not apply to your system. Napco control panels have such a wide variety of features that few security systems, if any, will ever need them all. Your alarm professional has chosen appropriate features for your particular needs.

Regardless of how your system has been configured, rest assured that it has been carefully designed and engineered to the highest industry standards. To assure optimum safety and security, familiarize yourself with this equipment. Periodically check its condition and state of readiness by testing it at least once a week in both the ac/battery and battery- only modes (ask your alarm professional how to make these tests).

IMPORTANT - TEST YOUR SYSTEM WEEKLY

Test your sounding device and backup battery

Test your central station communicator

(This test should only be performed on weekends or at a time

1. Notify your Central Station of the impending test.

designated by your alarm company.)

2. While disarmed, enter your User Code and press A.

1. While disarmed, press

.

 

 

A

3. Answer NO (press

) until “ACTIVATE DIALER TEST” appears

2. Answer NO (press F) until “ACTIVATE BELL TEST” appears in

in the window.

F

the window.

 

4. Press YES (E) to send a test code to the central station.

3. Press YES (E) to execute the test. The alarm will sound for about

If the test is not successful, “COMM FAIL E03-00 SERVICE” will

two seconds.

 

display, indicating a communication failure. Call for service.

If the alarm does not sound, call for service.

If the battery is

low, “LOW BATTERY E02-00 SERVICE” will

Note: Any subsequent successful transmission will clear a “Failure to

 

appear in the display indicating a low battery condition. Allow 24

Communicate” system trouble.

hours for the battery to recharge. If the trouble continues, call for service.

2

Image 2
Contents Operating Guide for T R O D U C T I O N Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators 01/01/00 1200 AMButton Reset Button ResetsInstant Area Button *. Selects otherBypassed B Y P a S S E D Bypassed 0 02 B a C K D O or Setting the Alarm Arming When LeavingSystem Ready W B a T T E R Y SYS/TRBL E02-00 Service System TroubleInstant Protection Protecting Yourself While on the PremisesBypassing Interior Zones Bypassed S Y S T E M R E a D YEasy Exit Optional Easy Exit programmed? !YES !NO V a L I D E N T R Y T R Y a G a I N Turning OFF the Alarm Disarming When ReturningA RM Fire-Zone Trouble Fire-Zone AlarmFire Protection Fire F I R E a L AR M Fire F I R E T R OU B L EImportant! Read Carefully Discuss these escape Would You Like More Safety Information?Family Rehearsal Floorplan FloorplanLimitations of Fire Alarm Warning Systems B Y P AS S E D Y / N Keypad FunctionsS P L a Y F a U LT S S P L a YKeypad Functions A R T I T T I M E S E T S T R B LN S O R M S G Y / N T I V a T E A L E R T E S T A R M I N 1 4 H R S E S S 1W N L O a D Y / N T I V a T EO G R a M Y / N L a YCommunicator Features Central Station MonitoringAdvanced Features Programming Optional User Program ModeEnter the User Program Mode Programming / Reprogramming a User CodeProgramming Example Exiting the User Program ModeReviewing a Programmed User Code R O N T D O O R Programming Zone DescriptionsEntering a new zone description To advance to the next zone or to any other zoneProgramming the Time Programming the system Date and TimeProgramming the Date T E R D a T ES TE M a R M E D I DA TE T I M E Keypad MessagesS T E M R E a D Y C DA TE T I M E N E S F a U LT E DAlarm R E T R B L R E Alarm N ’ T a R M S Y S T E M / a R E a # I N T R O U B L EM M F a I L T E M P T I N G T O C a N C E L A RM C a N C E L E DS T E M T R B L 3 0 0 S E R V I C EO S S a R Y Communicator Reports intrusions, emergencies, openingsO S S a R Y Fire Zone Detects fire alarms or trouble conditions E01-00 System Trouble Error CodesTrouble System Trouble Action Indication Condition E02-00E08-00 E06-NNE07-00 E09-00E12-NN E10-NNE11-NN E13-NNE21-00 E19-00E20-00 E23-00E40-00 E51-00Troubleshooting What do I do if For more infoT E S T E S Napco Limited Warranty Following Statement is Required by the FCC

GEM-X255 specifications

Napco Security Technologies has introduced the GEM-X255, a versatile and feature-rich control panel designed for both residential and commercial security applications. This advanced panel integrates multiple technologies to enhance security, streamline monitoring, and provide ease of use for both installers and end-users.

One of the standout features of the GEM-X255 is its ability to support a wide range of security devices. With up to 255 zones, the panel allows for extensive coverage, ensuring that every corner of a property can be monitored effectively. This scalability makes it an ideal choice for various applications, from small homes to larger commercial facilities.

The GEM-X255 utilizes both hardwired and wireless technologies, providing flexibility in installation. It can accommodate the latest security sensors, including motion detectors, door/window sensors, and glass break detectors, enabling users to tailor their security systems to meet specific needs. The panel supports popular wireless protocols, making it easier to expand the system with additional sensors without the hassle of wiring.

In terms of communication, the GEM-X255 features built-in IP communication capabilities, allowing users to connect to monitoring services and receive real-time alerts via smartphone apps. This ensures that users remain informed about their security status, even when they are away from the property. The clarity of these alerts is enhanced through its advanced notification system, which can deliver text messages and push notifications.

The GEM-X255 is designed with user experience in mind. It offers an intuitive user interface, complete with a backlit keypad for easy operation, even in low light conditions. The system also supports user codes, enabling multiple users to access the system securely while allowing the primary user to manage permissions efficiently.

An important aspect of the GEM-X255 is its robust automation capabilities. It can be programmed to control lights, locks, and other appliances, enhancing security while contributing to energy management. This integration of security and automation fosters a smarter home or business environment.

In summary, Napco Security Technologies' GEM-X255 combines innovative technology, extensive coverage, and user-friendly features to create a reliable security solution. Its adaptability to both wired and wireless devices, alongside robust communication capabilities, make it an invaluable asset for securing properties of any size. As security needs evolve, the GEM-X255 stands out as a modern control panel ready to meet the challenges of today and beyond.