Napco Security Technologies GEM-X255 manual T E M P T I N G T O C a N C E L A RM C a N C E L E D

Page 28

KEYPAD MESSAGES

A T T E M P T I N G T O C A N C E L

A L A RM C A N C E L E D

* * S Y S T E M T R B L * *

A C P O W E R F A I L E 0 1 - 0 0 S E R V I C E

L O W B A T T E R Y E 0 2 - 0 0 S E R V I C E

C O M M F A I L

E 0 3 - 0 0 S E R V I C E

The system is in the process of reporting a cancel signal to central station which will cancel the alarm which it has just reported.

The system has received an acknowledgment from central station of the cancellation of the alarm signal.

Indicates problem(s) detected on system. (See examples below and SYSTEM TROUBLE ERROR CODES for a complete list of system troubles and corrective actions.)

Check power transformer. Check for blown fuse or circuit breaker; general power outage.

Battery weak. If not recharged within 24 hours, replace battery.

Communication failure to central station.

28

Image 28
Contents Operating Guide for T R O D U C T I O N Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators 01/01/00 1200 AMReset Button Resets InstantButton Area Button *. Selects otherSystem Ready Setting the Alarm Arming When LeavingBypassed B Y P a S S E D Bypassed 0 02 B a C K D O or W B a T T E R Y SYS/TRBL E02-00 Service System TroubleProtecting Yourself While on the Premises Bypassing Interior ZonesInstant Protection Bypassed S Y S T E M R E a D YEasy Exit Optional Easy Exit programmed? !YES !NO A RM Turning OFF the Alarm Disarming When ReturningV a L I D E N T R Y T R Y a G a I N Fire-Zone Alarm Fire ProtectionFire-Zone Trouble Fire F I R E a L AR M Fire F I R E T R OU B L EFamily Rehearsal Would You Like More Safety Information?Important! Read Carefully Discuss these escape Floorplan FloorplanLimitations of Fire Alarm Warning Systems Keypad Functions S P L a Y F a U LT SB Y P AS S E D Y / N S P L a YKeypad Functions N S O R M S G Y / N S E T S T R B LA R T I T T I M E T I V a T E A L E R T E S T A R M I N 1 4 H R S E S S 1T I V a T E O G R a M Y / NW N L O a D Y / N L a YCommunicator Features Central Station MonitoringAdvanced Features User Program Mode Enter the User Program ModeProgramming Optional Programming / Reprogramming a User CodeReviewing a Programmed User Code Exiting the User Program ModeProgramming Example Programming Zone Descriptions Entering a new zone descriptionR O N T D O O R To advance to the next zone or to any other zoneProgramming the system Date and Time Programming the DateProgramming the Time T E R D a T EKeypad Messages S T E M R E a D Y C DA TE T I M ES TE M a R M E D I DA TE T I M E N E S F a U LT E DAlarm R E T R B L R E Alarm N ’ T a R M S Y S T E M / a R E a # I N T R O U B L ET E M P T I N G T O C a N C E L A RM C a N C E L E D S T E M T R B LM M F a I L 3 0 0 S E R V I C EO S S a R Y Communicator Reports intrusions, emergencies, openingsO S S a R Y Fire Zone Detects fire alarms or trouble conditions System Trouble Error Codes Trouble System Trouble Action Indication ConditionE01-00 E02-00E06-NN E07-00E08-00 E09-00E10-NN E11-NNE12-NN E13-NNE19-00 E20-00E21-00 E23-00E40-00 E51-00Troubleshooting What do I do if For more infoT E S T E S Napco Limited Warranty Following Statement is Required by the FCC

GEM-X255 specifications

Napco Security Technologies has introduced the GEM-X255, a versatile and feature-rich control panel designed for both residential and commercial security applications. This advanced panel integrates multiple technologies to enhance security, streamline monitoring, and provide ease of use for both installers and end-users.

One of the standout features of the GEM-X255 is its ability to support a wide range of security devices. With up to 255 zones, the panel allows for extensive coverage, ensuring that every corner of a property can be monitored effectively. This scalability makes it an ideal choice for various applications, from small homes to larger commercial facilities.

The GEM-X255 utilizes both hardwired and wireless technologies, providing flexibility in installation. It can accommodate the latest security sensors, including motion detectors, door/window sensors, and glass break detectors, enabling users to tailor their security systems to meet specific needs. The panel supports popular wireless protocols, making it easier to expand the system with additional sensors without the hassle of wiring.

In terms of communication, the GEM-X255 features built-in IP communication capabilities, allowing users to connect to monitoring services and receive real-time alerts via smartphone apps. This ensures that users remain informed about their security status, even when they are away from the property. The clarity of these alerts is enhanced through its advanced notification system, which can deliver text messages and push notifications.

The GEM-X255 is designed with user experience in mind. It offers an intuitive user interface, complete with a backlit keypad for easy operation, even in low light conditions. The system also supports user codes, enabling multiple users to access the system securely while allowing the primary user to manage permissions efficiently.

An important aspect of the GEM-X255 is its robust automation capabilities. It can be programmed to control lights, locks, and other appliances, enhancing security while contributing to energy management. This integration of security and automation fosters a smarter home or business environment.

In summary, Napco Security Technologies' GEM-X255 combines innovative technology, extensive coverage, and user-friendly features to create a reliable security solution. Its adaptability to both wired and wireless devices, alongside robust communication capabilities, make it an invaluable asset for securing properties of any size. As security needs evolve, the GEM-X255 stands out as a modern control panel ready to meet the challenges of today and beyond.