Napco Security Technologies GEM-K1CA manual Limitations of Fire Alarm Warning System

Page 14

FIRE PROTECTION

LIMITATIONS OF FIRE ALARM WARNING SYSTEM

Although a fire alarm system may be of a reliable and state-of- the-art design, neither it nor its peripheral detection devices can offer guaranteed protection against fire. Any such equipment may fail to warn for a variety of reasons:

Control panels, communicators, dialers, smoke detectors, and many other sensing devices will not work without power. Battery- operated devices will not work without batteries, with dead batteries, or with improperly-installed batteries. Devices powered solely by AC will not work if their power source is cut off for any reason.

Fires often cause a failure of electrical power. If the system does not contain a working battery backup power supply, and if the electrical circuit feeding the devices is cut or is not providing power for any reason, the system will not detect heat or smoke or provide any warning of a possible fire.

Telephone lines needed to transmit alarm signals to a central monitoring station may be out of service.

Smoke detectors, though highly effective in reducing fire deaths, may not activate or provide early-enough warning for a variety of

reasons: (a) they may not sense fires that start where smoke cannot reach them, such as in chimneys, walls, roofs, behind closed doors, etc.; (b) they may not sense a fire on a different level of the residence or building; (c) they have sensing limitations; no smoke detector can sense every kind of fire every time.

Thermostatic heat detectors do not always detect fires because the fire may be a slow smoldering low-heat type (producing smoke); because they may not be near the fire; or because the heat of the fire may bypass them. These detectors will not detect oxygen levels, smoke, toxic gases, or flames. Therefore, they may only be used as part of

acomprehensive fire-detection system in conjunction with other devices. Under no circumstances should thermostatic heat detectors be relied upon as the sole measure to ensure fire safety.

Alarm warning devices such as sirens, bells, or horns may not alert someone behind

aclosed or partially-opened door. Warning devices located on one level are less likely to alert those on a different level. Even those who are awake may not hear the warning if the alarm is obscured by noise from a stereo,

radio, air conditioner, or other appliance, or by passing traffic, etc. Alarm warning devices, however loud, may fail to warn the hearing impaired.

Alarm products, as all electrical devices, are subject to component failure. Even though the equipment is designed for many years of trouble-free performance, electronic components could fail at any time.

Above are some of the reasons that fire alarm equipment could fail. The most common cause of an alarm system not functioning when a fire occurs is inadequate testing and maintenance. The system should be tested at least weekly to ensure that all the equipment is working properly.

While an alarm system may make one eligible for lower insurance rates, it is not a substitute for insurance. Homeowners, property owners, and renters are therefore urged to maintain adequate insurance coverage of life and property.

14

Image 14
Contents 5 6 Q 8 9 0 GImportant Test Your System Weekly Test your sounding device and backup batteryIntroduction Test your central station communicatorTable of Contents Keypad Controls & Indicators Stay ResetEnter Arming AW AY Setting the Alarm When Leaving System ReadyAN ’ T ARM S YS TE M P R E SS R E SE T K EY W B AT TE R Y E02-00 ServiceSystem Trouble Instant Protection Arming in Stay ModeArming Stay Protecting Yourself AT Home Bypassed ARM E D S T AYPress Uto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Trouble Fire-Zone AlarmFire Protection Fire F I RE AL ARMImportant! Read Carefully Would You Like More Safety Information?Preparing a Fire Escape Plan Floorplan FloorplanLimitations of Fire Alarm Warning System Function Menu S PL AY F AU L TS B YP AS S E D Y/N DI RE C to RY Y/NTroubles. For GEM-P9600/3200 panels only S E T YS TR B L N SO R M SG Y/ N ART I T TI M E E SS AC TI V ATE DI ALE R Test Y/ N To ARM1 4 H RS AC TI V ATE O GR AM Y/N WNL O AD Y/ N L AY CON Trol Y/N Communicator Features Central Station MonitoringSecurity Bypass/Unbypass Advanced FeaturesExit-Delay Restart Programming Optional AC TI V ATE O GR AM EN TE R User CodeProgramming Example Program the User 3 Code to Exiting the User Program ModeReviewing a Programmed User Code Entering a new zone description Cell Phone-Style Entry Enter the User Program ModeProgramming Zone Descriptions AC TI V ATE O GR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the Time Programming the system Date and TimeProgramming the Date TE R TI MEKeypad Messages ARM E D S T AY I D ATE TI MEAL AR M RE TR BL RE AL ARM For partitioned systems only. Code not valid for area3 0 0 S ER V ICE AT TE M P TI N G to C AN CE L AL AR M C AN CE L EDCO MM F AI L Glossary Glossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE06-NN E04-NNE05-NN E12-NN E10-NNE11-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-K1CA specifications

Napco Security Technologies is renowned for its innovative security solutions, and the GEM-K1CA is no exception. This advanced security panel combines functionality with user-friendliness, making it a popular choice for both residential and commercial applications.

One of the standout features of the GEM-K1CA is its compact design. With a small footprint, it can be easily mounted in inconspicuous locations, making it ideal for discreet security setups. Despite its size, the panel is equipped with a range of capabilities that ensure maximum security for its users.

The GEM-K1CA is built around a powerful microprocessor that allows for quick processing times and a robust performance in monitoring and managing security alerts. This makes it capable of handling multiple inputs and outputs, allowing users to expand their security systems easily. The panel supports up to 16 zones, providing significant coverage for premises, and can integrate various sensors, ranging from door and window contacts to motion detectors.

Another significant feature is its user-friendly interface. The keypad is designed for intuitive operation, with backlit keys that are easy to read in low-light conditions. Users can quickly arm or disarm the system, check status indicators, or troubleshoot issues, all within a streamlined menu structure that simplifies daily operations.

Connectivity is another area where the GEM-K1CA excels. The panel supports both landline and cellular communicators, enabling effective communication with central monitoring stations. This flexibility ensures that users can choose the most reliable communication method for their specific environment, thereby enhancing the overall security experience.

In terms of programming, the GEM-K1CA allows for straightforward customization. Users can easily set their preferences for system notifications, codes, and automation settings. The system also supports real-time alerts, so users receive timely notifications regarding any security breaches.

Lastly, the GEM-K1CA is designed for longevity and reliability. Built with high-quality materials, it withstands various environmental conditions, ensuring that it remains functional in diverse settings. With Napco’s commitment to quality and performance, the GEM-K1CA is a dependable choice for anyone seeking an effective and user-friendly security solution.

In conclusion, the Napco Security Technologies GEM-K1CA stands out for its combination of compactness, advanced features, and user-focused design, making it a compelling choice for comprehensive security needs.