FUNCTION MENU

AC TI V ATE

DI ALE R TEST Y/ N

TO ARM

I N 1 - 4 H RS

P R E SS 1

- 4

/ N

 

 

 

Activate Telephone Test? (Telephone Test programmed? ‰YES ‰NO). Sends a communicator test to the central station. A communication failure will be indicated at the keypad by a system trouble “E03-FAIL TO COMM” display. Repeat the test to attempt to correct a communication failure, as any successful communication will clear this display.

Delay Arming 1-4 hours. (Not for UL-listed systems). Your system may be set to arm automatically after a delay period of 1 to 4 hours.

To Delay Arm the system:

With the function “TO ARM IN 1-4 HRS“ displayed in the window, enter the desired Delay Arming time in hours (1, 2, 3,or 4), followed by U.

At the end of this 1 - 4 hour Delay Arming period, the siren will sound a 2-second warning and the keypad will begin a 15-minute arming countdown with the sounder pulsing. The sounder may be silenced at this time by pressing C, but it will turn back on with a steady warning tone 1 minute prior to arming, at which time the building must be exited.

The same steps can be used to delay a scheduled Auto Arming, if your system has been programmed as such.

18

Image 18
Contents 5 6 Q 8 9 0 GImportant Test Your System Weekly Test your sounding device and backup batteryIntroduction Test your central station communicatorTable of Contents Keypad Controls & Indicators Reset EnterStay Arming AW AY Setting the Alarm When Leaving System ReadyW B AT TE R Y E02-00 Service System TroubleAN ’ T ARM S YS TE M P R E SS R E SE T K EY Instant Protection Arming in Stay ModeArming Stay Protecting Yourself AT Home Bypassed ARM E D S T AYPress Uto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Trouble Fire-Zone AlarmFire Protection Fire F I RE AL ARMWould You Like More Safety Information? Preparing a Fire Escape PlanImportant! Read Carefully Floorplan FloorplanLimitations of Fire Alarm Warning System Function Menu S PL AY F AU L TS B YP AS S E D Y/N DI RE C to RY Y/NTroubles. For GEM-P9600/3200 panels only S E T YS TR B L N SO R M SG Y/ N ART I T TI M E AC TI V ATE DI ALE R Test Y/ N To ARM 1 4 H RSE SS AC TI V ATE O GR AM Y/N WNL O AD Y/ N L AY CON Trol Y/N Communicator Features Central Station MonitoringAdvanced Features Exit-Delay RestartSecurity Bypass/Unbypass Programming Optional AC TI V ATE O GR AM EN TE R User CodeExiting the User Program Mode Reviewing a Programmed User CodeProgramming Example Program the User 3 Code to Entering a new zone description Cell Phone-Style Entry Enter the User Program ModeProgramming Zone Descriptions AC TI V ATE O GR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the Time Programming the system Date and TimeProgramming the Date TE R TI MEKeypad Messages ARM E D S T AY I D ATE TI MEAL AR M RE TR BL RE AL ARM For partitioned systems only. Code not valid for areaAT TE M P TI N G to C AN CE L AL AR M C AN CE L ED CO MM F AI L3 0 0 S ER V ICE Glossary Glossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE04-NN E05-NNE06-NN E12-NN E10-NNE11-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-K1CA specifications

Napco Security Technologies is renowned for its innovative security solutions, and the GEM-K1CA is no exception. This advanced security panel combines functionality with user-friendliness, making it a popular choice for both residential and commercial applications.

One of the standout features of the GEM-K1CA is its compact design. With a small footprint, it can be easily mounted in inconspicuous locations, making it ideal for discreet security setups. Despite its size, the panel is equipped with a range of capabilities that ensure maximum security for its users.

The GEM-K1CA is built around a powerful microprocessor that allows for quick processing times and a robust performance in monitoring and managing security alerts. This makes it capable of handling multiple inputs and outputs, allowing users to expand their security systems easily. The panel supports up to 16 zones, providing significant coverage for premises, and can integrate various sensors, ranging from door and window contacts to motion detectors.

Another significant feature is its user-friendly interface. The keypad is designed for intuitive operation, with backlit keys that are easy to read in low-light conditions. Users can quickly arm or disarm the system, check status indicators, or troubleshoot issues, all within a streamlined menu structure that simplifies daily operations.

Connectivity is another area where the GEM-K1CA excels. The panel supports both landline and cellular communicators, enabling effective communication with central monitoring stations. This flexibility ensures that users can choose the most reliable communication method for their specific environment, thereby enhancing the overall security experience.

In terms of programming, the GEM-K1CA allows for straightforward customization. Users can easily set their preferences for system notifications, codes, and automation settings. The system also supports real-time alerts, so users receive timely notifications regarding any security breaches.

Lastly, the GEM-K1CA is designed for longevity and reliability. Built with high-quality materials, it withstands various environmental conditions, ensuring that it remains functional in diverse settings. With Napco’s commitment to quality and performance, the GEM-K1CA is a dependable choice for anyone seeking an effective and user-friendly security solution.

In conclusion, the Napco Security Technologies GEM-K1CA stands out for its combination of compactness, advanced features, and user-focused design, making it a compelling choice for comprehensive security needs.