Napco Security Technologies GEM-K1CA manual Glossary

Page 30

GLOSSARY

Following are brief descriptions of terms and features used herein that may be unfamiliar to you. Some of the features are programmable options that may or may not apply to your particular system.

Abort Delay - A delay period that allows the control panel to be reset, thus aborting a report to a central station.

Access Code - A code (up to 6 digits) used to remotely unlock a door.

Ambush Code - A code entered when forced to disarm. Sends a silent alarm to the central station with no indication at the keypad. There are two types: (1) A 2-digit code (prefix) entered just prior to your nor- mal User Code and (2) A separate and unique User Code used in place of your normal User Code.

Area - Some systems may be divided, or partitioned, into smaller independent subsystems, which are referred to as Areas. Each Area may be controlled by its own keypad or by

a keypad of a different Area through Managers Mode..

Arming/Disarming - Turning the system on/off by entering your code

at the keypad, then pressing U.

Battery - Backup power source in the control-panel enclosure to provide protection in the event of a power failure.

BYPASS Button - Enables you to manually remove one or more protective zones from the system.

Central Station - Monitors incoming reports and emergency messages from a digital communicator and notifies the proper authorities.

Chime - A keypad beep while disarmed alerting that the

programmed zone has been opened.

Closing Window - (Optional.) A time interval within which closing (arming) is permitted without reporting to the central station.

Communicator - Reports intrusions, emergencies, openings, closings, etc. directly to the central station over telephone lines.

Control Panel - The brain of the system, it controls all system functions.

Directory - A listing of the programmed zone descriptions stored in memory.

Easy Arming - Quick arming by pressing U(optional).

30

Image 30
Contents 5 6 Q 8 9 0 GImportant Test Your System Weekly Test your sounding device and backup batteryIntroduction Test your central station communicatorTable of Contents Keypad Controls & Indicators Reset EnterStay Arming AW AY Setting the Alarm When Leaving System ReadyW B AT TE R Y E02-00 Service System TroubleAN ’ T ARM S YS TE M P R E SS R E SE T K EY Instant Protection Arming in Stay ModeArming Stay Protecting Yourself AT Home Bypassed ARM E D S T AYPress Uto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Trouble Fire-Zone AlarmFire Protection Fire F I RE AL ARMWould You Like More Safety Information? Preparing a Fire Escape PlanImportant! Read Carefully Floorplan FloorplanLimitations of Fire Alarm Warning System Function Menu S PL AY F AU L TS B YP AS S E D Y/N DI RE C to RY Y/NTroubles. For GEM-P9600/3200 panels only S E T YS TR B L N SO R M SG Y/ N ART I T TI M E AC TI V ATE DI ALE R Test Y/ N To ARM 1 4 H RSE SS AC TI V ATE O GR AM Y/N WNL O AD Y/ N L AY CON Trol Y/N Communicator Features Central Station MonitoringAdvanced Features Exit-Delay RestartSecurity Bypass/Unbypass Programming Optional AC TI V ATE O GR AM EN TE R User CodeExiting the User Program Mode Reviewing a Programmed User CodeProgramming Example Program the User 3 Code to Entering a new zone description Cell Phone-Style Entry Enter the User Program ModeProgramming Zone Descriptions AC TI V ATE O GR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the Time Programming the system Date and TimeProgramming the Date TE R TI MEKeypad Messages ARM E D S T AY I D ATE TI MEAL AR M RE TR BL RE AL ARM For partitioned systems only. Code not valid for areaAT TE M P TI N G to C AN CE L AL AR M C AN CE L ED CO MM F AI L3 0 0 S ER V ICE Glossary Glossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE04-NN E05-NNE06-NN E12-NN E10-NNE11-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-K1CA specifications

Napco Security Technologies is renowned for its innovative security solutions, and the GEM-K1CA is no exception. This advanced security panel combines functionality with user-friendliness, making it a popular choice for both residential and commercial applications.

One of the standout features of the GEM-K1CA is its compact design. With a small footprint, it can be easily mounted in inconspicuous locations, making it ideal for discreet security setups. Despite its size, the panel is equipped with a range of capabilities that ensure maximum security for its users.

The GEM-K1CA is built around a powerful microprocessor that allows for quick processing times and a robust performance in monitoring and managing security alerts. This makes it capable of handling multiple inputs and outputs, allowing users to expand their security systems easily. The panel supports up to 16 zones, providing significant coverage for premises, and can integrate various sensors, ranging from door and window contacts to motion detectors.

Another significant feature is its user-friendly interface. The keypad is designed for intuitive operation, with backlit keys that are easy to read in low-light conditions. Users can quickly arm or disarm the system, check status indicators, or troubleshoot issues, all within a streamlined menu structure that simplifies daily operations.

Connectivity is another area where the GEM-K1CA excels. The panel supports both landline and cellular communicators, enabling effective communication with central monitoring stations. This flexibility ensures that users can choose the most reliable communication method for their specific environment, thereby enhancing the overall security experience.

In terms of programming, the GEM-K1CA allows for straightforward customization. Users can easily set their preferences for system notifications, codes, and automation settings. The system also supports real-time alerts, so users receive timely notifications regarding any security breaches.

Lastly, the GEM-K1CA is designed for longevity and reliability. Built with high-quality materials, it withstands various environmental conditions, ensuring that it remains functional in diverse settings. With Napco’s commitment to quality and performance, the GEM-K1CA is a dependable choice for anyone seeking an effective and user-friendly security solution.

In conclusion, the Napco Security Technologies GEM-K1CA stands out for its combination of compactness, advanced features, and user-focused design, making it a compelling choice for comprehensive security needs.