Napoleon Fireplaces GDS25P, GDS25N manual Symptom, Do not Clean Glass When HOT

Page 27

 

 

 

 

27

 

 

 

 

 

 

SYMPTOM

 

PROBLEM

TEST SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot lights

 

- Wiring / Connection

Inspect all wires, ensure good tight connections. Verify that all

 

 

Stops sparking

 

 

wiring is installed exactly as specified.

 

 

/ pilot remains lit

 

- Wiring harness

Inspect the wiring harness, and verify the harness is tightly con-

 

but burner will

 

 

 

 

nected to the module. Verify that you have 7 wires and they are

 

not turn on

 

 

 

 

 

connected in the right order.

 

 

 

 

 

 

 

 

 

 

 

 

 

- Module or Valve

Conduct the following test to verify if the problem is the module or

 

 

 

 

valve. To measure voltages, turn multimeter to "DC" place the red

 

 

 

 

lead from multimeter on the screw on the terminal block for the

 

 

 

 

wire you are checking, touch black lead to ground (valve body).

 

 

 

 

Importantly, a "Zero" volts reading does not automatically indicate

 

 

 

 

a bad module, there may be too little resistance in the valve sole-

 

 

 

 

noid. Check the Green wire disconnected from valve that the volt-

 

 

 

 

age output from the module should be between 2 and 3 volts

 

 

 

 

 

 

Exhaust fumes smelled

 

- Fireplace is spilling.

Check all seals.

in room, headaches.

 

 

 

 

Carbon is being depos- ited on glass, logs or combustion chamber surfaces.

- Air shutter has become

Ensure air shutter opening is free of lint or other obstructions.

blocked

 

 

 

- Flame is impinging on the

Check that the logs are correctly positioned.

logs or combustion chamber.

Open air shutter to increase the primary air.

 

Check the input rate: check the manifold pressure and orifice

 

size as specified by the rating plate values.

 

Check that the door gasketing is not broken or missing and

 

that the seal is tight.

 

Check that both vent liners are free of holes and well sealed

 

at all joints.

 

Check that minimum rise per foot has been adhered to for

 

any horizontal venting.

Flames are very ag- - Door is ajar

Tighten door clamps

gressive.

 

 

 

- Venting action is too great.

Restrict vent exit with restrictor plate. See Restricting Vents.

 

Main burner flame is a blue, lazy, transparent flame.

- Blockage in vent.

Remove blockage. In really cold conditions, ice buildup may occur

 

on the terminal and should be removed as required.

- Incorrect installation (vertical

Refer to Figure 24 to ensure correct location of storm collars.

termination only).

 

White / grey film

- Sulphur from fuel is being de

forms.

posited on glass, logs or

 

combustion chamber

 

surfaces.

Clean the glass with a recommended gas fireplace glass cleaner.

DO NOT CLEAN GLASS WHEN HOT.

If deposits are not cleaned off regularly, the glass may become permanently marked.

W415-0547 / C / 07.25.06

Image 27
Contents W415-0547 / C What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Location & Clearances Stove DimensionsNight Light Replacement Blower InstallationAIR Terminal Locations Part Supplier Typical Corner Install With Zero RiseVenting Venting Lengths AIR Terminal LocationsSpecial Vent Installations Typical Vent InstallationsRequired Vertical R I S E I N Feet VT Horizontal TerminationDefinitions Elbow Vent Length ValuesHT + VT Formula 2 HT + VT 24.75 feetHT VT Vertical Termination+ VT =HR + HO = 8 + 5.4 = 13.4 ft = 13.4 + 2.5 = 15.9 ft 3VTVertical Through Existing Chimney InstallationFor Safe and Proper Vertical InstallationHorizontal Installation Wall and Ceiling ProtectionHorizontal Venting Installation Vertical Venting InstallationRestricting Vertical Vents Mobile Home InstallationGAS Installation Stove Vent ConnectionDoor Latches Cast Front InstallationSwitch Functions FinishingLOG Placement Logo PlacementWire Size MAX. Length Optional Switch / Wiring DiagramTo Turn OFF GAS Operating InstructionsVenturi Adjustment AdjustmentsMaintenance Pilot Injector and Orifice ReplacementReplacements Page Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT SymptomFireplace Service History

GDS25N, GDS25P specifications

Napoleon Fireplaces has long been renowned for its innovative and high-quality heating solutions, and the GDS25P and GDS25N gas fireplaces are no exception. These models are designed to bring warmth and ambiance to any living space, offering both functionality and style.

The GDS25P, a built-in direct vent gas fireplace, is particularly sought after for its contemporary aesthetics and efficient heating capabilities. With a generous heat output, it can effectively warm large rooms while maintaining a cozy atmosphere. The GDS25N, on the other hand, is the free-standing variant that provides the same impressive heat performance in a stand-alone format, ideal for various room layouts.

One of the standout features of both models is their Clean Face Design. This creates a modern, sleek appearance without the need for bulky trim or surrounds, allowing for a larger viewing area of the dancing flames. The advanced glass viewing area promotes a realistic fire experience, enhancing the visual appeal of any space.

In terms of technology, Napoleon incorporates innovative features such as the Firebox with its patented technology that allows for easy adjustments for optimal flame height. The adjustable flame control ensures that users can customize their experience, enjoying everything from a gentle glow to a roaring fire.

Additionally, both models are equipped with a fan-assisted heat system, which aids in the distribution of warmth throughout the room. This is particularly beneficial during the colder months, as it enhances the overall efficiency of the fireplace.

For safety and convenience, the GDS25P and GDS25N come with an optional remote control system, allowing users to operate the fireplace from across the room. This feature adds an extra layer of comfort, making it easy to adjust settings without needing to get up.

Energy efficiency is another hallmark of these Napoleon fireplaces. They are designed to operate with minimal gas consumption while providing maximum heat output, making them an eco-friendly choice.

With customizable options, including various decorative media like glass or logs, homeowners can personalize their fireplaces to match their interior décor. The GDS25P and GDS25N are not just heating appliances; they are stylish focal points that elevate the ambiance of any home.

In summary, the Napoleon GDS25P and GDS25N gas fireplaces stand out due to their modern design, advanced technology, efficient heating capabilities, and personal customization options. With these models, homeowners can enjoy the warmth and aesthetic appeal of a fireplace without compromising on efficiency or style.