Spacers are attached to the 4" inner flex liner at prede- termined intervals to maintain a 1-1/4" air gap to the 7" outer liner. These spacers must not be removed.

7.If more liner needs to be used to reach the fireplace, couple them together as illustrated in FIGURE 13. The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel support ring assembly W010-0370or equivalent noncombustible strap- ping to maintain a clearance to combustibles of 1".

FIREPLACE VENT CONNECTION

1.Install the 4 inch diam-

eter aluminum flexible

FIGURE 23

 

liner to the fireplace. Se-

 

cure with 3 screws and flat

 

washers. Seal the joint

 

and screw holes using

 

the high temperature seal-

 

ant Mill Pac.

 

2.Install the 7 inch diameter alu- minum flexible liner to the fireplace. Attach and seal the joints.

USING RIGID VENT COMPONENTS

For optimum performance it is recommended that all horizontal runs have a ¼ inch rise per foot.

For safe and proper operation of the fireplace, follow the venting instructions exactly.

The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Napoleon vent spacers W615-0033every 3 feet and on either side of each elbow to maintain the minimum 1¼" clearance be- tween the outer and inner vent pipes. Use Napoleon sup- port ring assembly W010-0370or equivalent noncombus- tible strapping to maintain the minimum 1" clearance to combustibles for both vertical and horizontal runs.

All inner exhaust and outer intake vent pipe joists may be sealed using either Red RTV high temp silicone seal- ant or Black high temp Mill Pac with the exception of the fireplace exhaust flue collar which must be sealed us- ing Mill Pac (not supplied).

HORIZONTAL AIR TERMINAL INSTALLATION

1.Move the fireplace into position. Measure the vent length required between terminal and fireplace taking into account the additional length needed for the finished wall surface and any 1¼" overlaps between venting components.

2.Apply high temperature sealant Mill Pac to the outer edge of the 4" inner collar of the fireplace. Attach the first vent component and secure using 3 self tapping screws. Re- peat using 7" piping.

3.Holding the air terminal (lettering in an upright, readable position), insert into both vent pipes with a twisting motion to ensure that both the terminal sleeves engage into the vent pipes and the sealant. Secure the terminal to the exte- rior wall and make weather tight by sealing with caulking (not supplied). The air terminal may be recessed into the exterior wall or siding by 1½", the depth of the return flange.

FIGURE 24

VERTICAL VENTING INSTALLATION

1.Move the fireplace into position.

2.Fasten the roof support to the

roof using the screws provided.

FIGURE 25

FIGURE 16. The roof support is

 

optional. In this case the venting

 

is to be adequately supported

 

using either an alternate method

 

suitable to the authority having ju-

 

risdiction or the optional roof sup-

 

port.

 

3.Apply high temperature seal- ant to the outer edge of the inner sleeve of the air terminal. Slip a 4" diameter coupler a minimum

of 2" over the sleeve and secure using 3 screws.

4. Apply high temperature sealant to the outer edge of the of the outside sleeve of the air terminal. Slip a 7" diameter coupler over the sleeve and secure as before. FIGURE 19. Trim the 7" coupler even with the 4" coupler end.

5. Thread the air terminal pipe assembly down through the roof support and attach, ensuring that a minimum 16" of air terminal will penetrate the roof when fastened.

FIGURE 18. If the attic space is tight, we recommend threading the Wolf Steel vent pipe collar or equivalent loosely onto the air terminal assembly as it is passed through the attic. The air terminal must be located verti- cally and plumb.

6. Remove nails from the shingles, above and to the sides of the chimney. Place the flashing over the air terminal and slide it underneath the sides and upper edge of the shingles. Ensure that the air terminal is properly centered within the flashing, giving a 3/4" margin all around. Fasten to the roof. Do NOT nail through the lower portion of the flashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the flashing with roofing material.

7.Apply a heavy bead of waterproof caulking 2 inches above the flashing. Slide the storm collar around the air terminal and down to the caulking. Tighten to ensure that a weather- tight seal between the air terminal and the collar is achieved. Attach the other storm collar centered between the air in- take and air exhaust slots onto the air terminal. Tighten securely. Attach the rain cap.

W415-0434 / C / 03.24.05

Image 13
Contents Vented GAS Fireplace Heater Direct Vent Millivolt System Please Retain this Manual for Future Reference Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values H2 H3 Vertical Termination Formula 1 H T 3V T Formula 2 H T + V T 40 feet Example AIR Terminal Installations Horizontal Installation Installation Wall and Ceiling ProtectionVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Vertical Venting Installation Using Rigid Vent ComponentsFireplace Vent Connection Mobile Home Installation GAS InstallationRestricting Vertical Vents FramingExample a NON-COMBUSTIBLE Material Mantle ClearancesFlush Finish Example B Bevelled TrimFinishing Decorative Panels L38 Louvre Installation LOG Shipping BracketCharcoal Strips Baffle Installation LOG PlacementGlowing Embers Charcoal EmbersLine Switch Accent Lite ReplacementThermodisc Replacement Blower InstallationBlower System Operating Instructions Operation / MaintenanceMaintenance AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacements W415-0434 / C Symptom Problem Test Solution Trouble Shooting GuideMain burner orifice is plugged Fireplace Service History W415-0434 / C

GD70PT-S, GD70NT-S specifications

The Napoleon Fireplaces GD70NT-S and GD70PT-S are exemplary models that elevate the standard for modern gas fireplaces. Combining sophistication with advanced technology, these units are designed for homeowners seeking both aesthetic appeal and functional efficiency.

One of the standout features of the GD70NT-S and GD70PT-S is their large viewing area. The spacious firebox allows for a stunning display of flames, creating a captivating focal point in any room. Both models offer a sleek design that complements various interior styles, from contemporary to traditional, ensuring versatility in decor.

The GD70NT-S is designed for natural gas operation, while the GD70PT-S is equipped for propane, allowing users to choose the fuel type that best fits their needs. This adaptability makes both models an excellent choice for different households. With their advanced heat exchanger, these fireplaces maximize heat output while minimizing energy consumption, contributing to a more environmentally friendly heating solution.

As for efficiency, the GD70NT-S and GD70PT-S boast impressive ratings, allowing homeowners to enjoy the comforting ambiance of a fireplace without unnecessarily high energy bills. Their electronic ignition systems provide easy startup, ensuring that warmth is just a button press away, even during cold winter months.

Safety is another critical consideration in the design of these fireplaces. The units come with a safety screen that prevents accidental contact with hot surfaces, while built-in flame sensors ensure that the fireplace operates safely and effectively. These features offer peace of mind, making them a reliable choice for family homes.

Moreover, Napoleon has incorporated cutting-edge technologies in these models, such as a modulating flame feature that allows users to adjust the fire's intensity according to their comfort needs. The remote control option provides added convenience, letting users operate their fireplace from a distance with ease.

In conclusion, the Napoleon Fireplaces GD70NT-S and GD70PT-S are remarkable options for anyone looking to enhance their living space with a high-quality gas fireplace. With their elegant designs, energy-efficient performance, and advanced safety features, these models represent the perfect blend of functionality and style, making them an excellent investment for any home. Whether for heating purposes or creating an inviting ambiance, the GD70 series stands out as a premier choice.