MASSACHUSETTS RESIDENTS ONLY: PLEASE READ AND FOLLOW THESE SPECIAL REQUIREMENTS

NOTE REGARDING VENTED PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

Any residence with a direct vent product must have a CO detector installed in the residence.

Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.

In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve.

NOTE REGARDING VENT FREE PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Mas- sachusetts.

Flex line installation must not exceed 36 inches and must have a T shutoff valve.

CARBON MONOXIDE DETECTOR REQUIREMENTS

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be in- stalled.

36

81D0107

Image 36
Contents Model NB18, NB24 Read and Save These InstructionsWhat to do if YOU Smell GAS Contents Important Safety Information InstallerOwner Massachussetts Residents only What YOU will Need for Installation Getting StartedMake Sure YOU have Received ALL Parts Product Features and Specifications General Installation Information CodesAdequate Combustion and Ventilation AIR BTU / Hr = Fireplace and Hearth Dimensions ModelPlacement in a Fireplace with a Restrictive Barrier Height of Restriction Minimum Depth of Fireplace/FireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Measuring Heat Resistant Material for Mantel Minimum Mantel Clearance with No Hood -NB18 Mum of 10 at a minimum of 28 above the opening Floor Clearance Minimum Clearance above Combustible FlooringInstalling Vented Applications Before Fully Installing the UnitBefore Installing the Appliance Damper Stop InstallationInstalling Vented Applications Assembly ProcedurePlacing and Securing Appliance Connecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveChecking GAS Pressure Millivolt Valve Control FigureElectrical Wiring Millivolt Connecting Optional Wall Switch or ThermostatATE Connecting Remote Receiver Checking System OperationComplete Millivolt System Check LOG Placement Placing Rock WoolPlacing Log #3 EMBER, GRATE, and Rock Installation Cast Iron Grate InstallationPlacing Flickering Embers Placing the Decorative RockFlame Appearance Checking the Pilot FlameMillivolt Control and Thermostat Control Checking the Burner Flame Operating InstructionsOperating Instructions What to do if YOU Smell GASTo Turn OFF GAS to Heater Operating Instructions and Cleaning and Servicing Cleaning and ServicingTroubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame Replacement Parts Burner AssemblyReplacement Parts List Accessories Sold SeparatelyBerkley OAK Refractory Logs Description Qty BO18-R BO18-F BO24-R BO24-F BO30-R BO30-FCarbon Monoxide Detector Requirements Special Requirements 81D0107 81D0107 Lifetime Warranty Five Year WarrantyBasic Warranty