Monessen Hearth NB24, NB18 operating instructions Product Features and Specifications

Page 6

PRODUCT FEATURES AND SPECIFICATIONS

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 10 1/2" W.C. on natural gas systems operating at higher pressure.

MILLIVOLT

 

Model Number

Control

Gas Rate

Regulator Pressure Setting: 3.5" w.c.

Max BTU/Hr

Min BTU/Hr

NB18NV

Millivolt

28,000

19,000

Pilot Regulator:

3.5" w.c.

NB24NV

Millivolt

37,000

25,000

Gas Inlet Pressure:

Max 101/2" w.c.

 

 

 

 

Min. 5" w.c.

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

MILLIVOLT

 

 

 

Gas Rate

Regulator Pressure Setting: 10" w.c

Model Number

Control

Max BTU/Hr

Min BTU/Hr

Gas Inlet Pressure:

Max. 13" w.c.

NB18PV

Millivolt

27,000

22,000

NB24PV

Millivolt

36,000

28,000

 

Min. 11" w.c.

 

 

 

 

 

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.

Millivolt control has four (4) positions:

OFF

- All gas to the gas logs is shut off at the valve.

IGN

- Valve position to light/maintain a standing pilot.

ON

-

Valve position to turn ON/OFF log set with remote switch/thermostat.

LOW/HI

-

Variable position to control flame height (heat output).

PILOT/ODS

The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail- able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a Millivolt (thermopile) generator to provide power for remote activation.

6

81D0107

Image 6
Contents Model NB18, NB24 Read and Save These InstructionsWhat to do if YOU Smell GAS Contents Important Safety Information InstallerOwner Massachussetts Residents only What YOU will Need for Installation Getting StartedMake Sure YOU have Received ALL Parts Product Features and Specifications General Installation Information CodesAdequate Combustion and Ventilation AIR BTU / Hr = Fireplace and Hearth Dimensions ModelPlacement in a Fireplace with a Restrictive Barrier Height of Restriction Minimum Depth of Fireplace/FireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Measuring Heat Resistant Material for Mantel Minimum Mantel Clearance with No Hood -NB18 Mum of 10 at a minimum of 28 above the opening Floor Clearance Minimum Clearance above Combustible FlooringBefore Installing the Appliance Installing Vented ApplicationsBefore Fully Installing the Unit Damper Stop InstallationInstalling Vented Applications Assembly ProcedurePlacing and Securing Appliance Connecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveChecking GAS Pressure Millivolt Valve Control FigureElectrical Wiring Millivolt Connecting Optional Wall Switch or ThermostatATE Connecting Remote Receiver Checking System OperationComplete Millivolt System Check LOG Placement Placing Rock WoolPlacing Log #3 Placing Flickering Embers EMBER, GRATE, and Rock InstallationCast Iron Grate Installation Placing the Decorative RockFlame Appearance Checking the Pilot FlameMillivolt Control and Thermostat Control Checking the Burner Flame Operating InstructionsOperating Instructions What to do if YOU Smell GASTo Turn OFF GAS to Heater Operating Instructions and Cleaning and Servicing Cleaning and ServicingTroubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame Replacement Parts Burner AssemblyReplacement Parts List Accessories Sold SeparatelyBerkley OAK Refractory Logs Description Qty BO18-R BO18-F BO24-R BO24-F BO30-R BO30-FCarbon Monoxide Detector Requirements Special Requirements 81D0107 81D0107 Lifetime Warranty Five Year WarrantyBasic Warranty