Monessen Hearth EYF18, EYF24 manual GCUF32,36,42 and VFR32,36,42 Series Fireboxes

Page 7
The log set should be placed against or as near as possible to the rear wall of the fireplace/firebox.

FIREPLACE and HEARTH DIMENSIONS

EYF Series Unvented Gas Log Set

WARNING

This appliance has been specifically tested and design certified for installation only in a solid-fuel burning fireplace including factory-built UL127 fireplaces and masonry fireplaces, or in a listed ventless firebox (see below).

Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs.

Use manufacturer's installation and clearance requirements as defined in their manual.

The EYF Series unvented room heater is approved for installation into the following unvented fireplaces:

GCUF(32,36,42) and VFR(32,36,42) Series Fireboxes

The EYF Series unvented room heater may also be in- stalled into a Ventless Firebox Enclosure for Gas Fired Decorative Type Unvented Room Heaters per ANSI Z21.91b.2004, as long as firebox hearth dimensions meet the minimum hearth dimensions shown below.

C

D

FP2530

 

A

 

 

 

 

 

 

B

 

 

 

 

 

 

Model

A

B

C

D

EYF18

5"

13"

17Z\x"

17"

Important information for the instal- lation of this gas log set in a fire- place with a restrictive barrier

The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom front opening of the fireplace. Some examples of barri- ers are glass/screen door frames and sunken/recessed fireplaces.

Height of

Minimum Depth of

Restriction (x)

Fireplace/Firebox

No Restriction

13”

1/2” to 1Z\x

16”

Greater than 1Z\x” to 3”

16”

Greater than 3”

*

*Any barrier greater than 3” placed in front of the gas log set is not recommended by the manufacturer.

NOTE: Non combustible material such as refractory brick may be used to line the floor of the fireplace in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the minimum height dimension listed in the homeowner’s manual must not be exceeded.

NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life by increasing the ambient temperature inside the fireplace. Placement of the receiver outside of the fireplace will extend the battery life.

 

(635 mm)

(330 mm)

(445 mm)

(433 mm)

EYF24 w/

29"

13"

19Z\x"

17"

EYF24-(R,F)

(737 mm)

(330 mm)

(495 mm)

(433 mm)

EYF24 w/

33"

13"

25Z\v"

17"

EYF30-R

(838 mm)

(330 mm)

(641 mm)

(433 mm)

Figure 2 -

Hearth Minimum Dimension for Solid Fuel Burning Fireplaces and UL127 Factory Built Fireplaces

WARNING

Barriers such as the bottom of a glass door

frame placed in front of a gas log set can

 

change the air flow characteristics of the fireplace which in turn can cause the unit to overheat and malfunction.

65D1009

Glass door frames with adjustable louvers should have the louvers fully open while the unit is in operation

X

Height of restrictive barrier

LO

 

caused by glass door frames,

 

OFF N

 

 

ON

 

HI

I

 

 

G

recessed fireplaces, etc. from

 

 

the base or bottom surface of

 

 

the unit.

 

 

Figure 3 -

Reference Drawing of a Natural Flame Log

Set in an Enclosure

FP2531

Refer to Table 1

Image 7
Contents Natural Gas or Propane/LPG Control Type Manual or Millivolt Unvented Gas Log Heater or Vented Decorative ApplianceAdequate Combustion Gas Code, Ansi Z223.l/NFPA54 Important Safety InformationNational Fire Protection Association, Inc American National Standards Institute, IncGAS pressures What you will need for installa- tionGas Specifications Make sure you have received all partsAdequate Combustion and Ventilation AIR Height Minimum Depth Restriction GCUF32,36,42 and VFR32,36,42 Series FireboxesOR, extend heat Clearance and Height RequirementsHeat Resistant Material InstallationMeasurement Other Combustible Projection Before installing the appliance Installation Fireplace PreparationBefore fully installing the unit Installing Vented ApplicationsPlace and Secure Appliance InstallationDamper stop installation Assembly procedureIng plate. If the gas supply is different, do GAS Line ConnectionManual Control Millivolt ControlConnecting Optional Wall Switch or Thermostat Electrical Wiring MillivoltContacts Should Be Connect Switch orChecking System Operation Check Meter Leads Thermostat Reading TestMay cause sooting. Only place volcanic rock LOG PlacementInstall EYF24-F log unit on burner Place the decorative rockPlace EYF18-R Logs Place EYF24-R and EYF30-R log setS Manual & HI/LO Control Flame AppearanceOperating Instructions What to do if YOU Smell GAS For Your SAFETY, Read Before LightingOperating Instructions Manual control lighting instructionsTo Turn OFF GAS to Heater Match lighting instructions MaintenanceTroubleshooting Problem Possible Cause SolutionTroubleshooting Replacement Parts EYF18-R EYF24-F EYF24-R EYF30-R DescriptionEYF Series Unvented Gas Log Set EYF Series Unvented Gas Log Set Carbon Monoxide Detector Requirements Limitations and Exclusions What is covered and for How LongWhat is Not Covered If Warranty Service is NeededMhsc
Related manuals
Manual 36 pages 14.74 Kb

EYF24, EYF18 specifications

The Monessen Hearth EYF24 and EYF18 represent a perfect blend of style, efficiency, and innovative technology in the world of vent-free gas fireplaces. Designed for homeowners who desire warmth and ambiance without the complexities of traditional fireplaces, these units stand out as reliable heating solutions.

The EYF24 and EYF18 are designed with a sleek and modern aesthetic, making them suitable for a variety of home decors. Their compact size allows for versatile installation options, making them ideal for both small spaces and larger living areas. With a focus on ease of use, both models come equipped with user-friendly controls, enabling homeowners to adjust the flame height and heat output effortlessly.

One of the standout features of these Monessen fireplaces is their vent-free technology. This allows the units to operate efficiently without the need for a chimney or flue, which means less installation cost and hassle. The design also facilitates greater flexibility in placement, as they can be installed in virtually any room. Whether you want to enhance a cozy den or add warmth to a larger gathering space, the EYF24 and EYF18 are adaptable to your needs.

Another notable characteristic is their high-efficiency rating. Both models utilize advanced burner technology that maximizes heat output while minimizing energy consumption. This capability not only ensures a comfortable indoor environment but also helps in reducing heating costs. The units are designed to generate realistic flames, creating an inviting ambiance that can be enjoyed year-round.

In terms of safety, Monessen has integrated several features into the EYF24 and EYF18. The oxygen depletion sensor (ODS) automatically shuts off the unit if oxygen levels fall below safe limits, providing peace of mind for homeowners. Additionally, the units are designed to operate quietly, allowing for an undisturbed living experience.

Customization options also abound with these models. Homeowners can select from a range of decorative media, including logs, stones, and glass, to personalize their fireplace's appearance. This flexibility ensures that each installation can be uniquely tailored to match individual tastes and home styles.

In conclusion, the Monessen Hearth EYF24 and EYF18 fireplaces are excellent choices for anyone seeking a stylish, efficient, and safe heating solution. With their modern design, vent-free technology, and user-friendly features, they offer an inviting and warm atmosphere that can enhance any home environment.