Vented Gas Logs
| Classic | Colossal |
| Manual Control |
|
| Manual SPK Control |
| Millivolt Control / |
| Radiant | ||||||
| Series | Series | Fuel | Minimum Hearth Area |
| Minimum Hearth Area |
| Minimum Hearth Area |
|
| Heat | ||||||
Model | Log Size | Log Size* | Type | Front | Depth | Back | Height | Front | Depth | Back | Height | Front | Depth | Back | Height | BTU/H | Output |
CSA VENTED GAS LOGS | REFRACTORY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
VWF18 | 18” | 24” | NG | - | - | - | - | 24 | 13 1/2” | 21” | 16” | 28” | 13 1/2” 25” | 16” | 60,000 | 14,000 | |
VWF18 | 18” | 24” | LP | - | - | - | - | 24 | 13 1/2” | 21” | 16” | 28” | 13 1/2” | 25” | 16” | 60,000 | 14,000 |
VWF24 | 24” | 30” | NG | - | - | - | - | 30 | 13 1/2” | 27” | 16” | 34” | 13 1/2” | 31” | 16” | 70,000 | 16,000 |
VWF24 | 24” | 30” | LP | - | - | - | - | 30 | 13 1/2” | 27” | 16” | 34” | 13 1/2” | 31” | 16” | 60,000 | 14,000 |
VWF30 | 30” | 36” | NG | - | - | - | - | 36 | 13 1/2” | 33” | 16” | 40” | 13 1/2” | 37” | 16” | 80,000 | 18,000 |
VWF30 | 30” | 36” | LP | - | - | - | - | 36 | 13 1/2” | 33” | 16” | 40” | 13 1/2” | 37” | 16” | 60,000 | 14,000 |
VWF36 | 36” | - | NG | - | - | - | - | 42 | 13 1/2” | 39” | 16” | 46” | 13 1/2” | 41” | 16” | 90,000 | 22,000 |
VWF36 | 36” | - | LP | - | - | - | - | 42 | 13 1/2” | 39” | 16” | 46” | 13 1/2” | 41” | 16” | 60,000 | 14,000 |
VWF18ST | 18” | - | NG | - | - | - | - | - | - | - | - | 28” | 16” | 28” | 16” | 60,000 | 14,000 |
VWF18ST | 18” | - | LP | - | - | - | - | - | - | - | - | 28” | 16” | 28” | 16” | 60,000 | 14,000 |
VWF24ST | 24” | - | NG | - | - | - | - | - | - | - | - | 34” | 16” | 34” | 16” | 70,000 | 16,000 |
VWF24ST | 24” | - | LP | - | - | - | - | - | - | - | - | 34” | 16” | 34” | 16” | 60,000 | 14,000 |
RADCO VENTED GAS LOGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
VWF18 | 18” | 24” | NG | 22” | 13” | 19” | 16” | 24” | 13 1/2” | 21” | 16” | 28” | 13 1/2” 25” | 16” | 80,000 | 18,000 | |
VWF18 | 18” | 24” | LP | 22” | 13” | 19” | 16” | 24” | 13 1/2” | 21” | 16” | 28” | 13 1/2” 25” | 16” | 60,000 | 14,000 | |
VWF24 | 24” | 30” | NG | 28” | 13” | 25” | 16” | 30” | 13 1/2” | 27” | 16” | 34” | 13 1/2” 31” | 16” | 90,000 | 20,000 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
VWF24 | 24” | 30” | LP | 28” | 13” | 25” | 16” | 30” | 13 1/2” | 27” | 16” | 34” | 13 1/2” 31” | 16” | 60,000 | 14,000 | |
VWF30 | 30” | 36” | NG | 34” | 13” | 31” | 16” | 36” | 13 1/2” | 33” | 16” | 40” | 13 1/2” 37” | 16” | 90,000 | 22,000 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
VWF30 | 30” | 36” | LP | 34” | 13” | 31” | 16” | 36” | 13 1/2” | 33” | 16” | 40” | 13 1/2” 37” | 16” | 60,000 | 14,000 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
VWF36 | 36” | - | NG | 38” | 13” | 37” | 16” | 42” | 13 1/2” | 39” | 16” | 46” | 13 1/2” 41” | 16” | 90,000 | 22,000 | |
VWF36 | 36” | - | LP | 38” | 13” | 37” | 16” | 42” | 13 1/2” | 39” | 16” | 46” | 13 1/2” 41” | 16” | 60,000 | 14,000 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VWF18ST | 18” | - | NG | 24” | 16” | 20” | 16” | 24” | 16” | 24” | 16” | 28” | 16” | 28” | 16” | 80,000 | 18,000 |
VWF18ST | 18” | - | LP | 24” | 16” | 20” | 16” | 24” | 16” | 24” | 16” | 28” | 16” | 28” | 16” | 60,000 | 14,000 |
VWF24ST | 24” | - | NG | 28” | 16” | 26” | 16” | 30” | 16” | 30” | 16” | 34” | 16” | 34” | 16” | 90,000 | 20,000 |
VWF24ST | 24” | - | LP | 28” | 16” | 26” | 16” | 30” | 16” | 30” | 16” | 34” | 16” | 34” | 16” | 60,000 | 14,000 |
|
|
|
| Manual Control |
|
| Millivolt | Control |
|
|
| Radiant |
|
|
| ||
|
|
| Fuel | Minimum Hearth Area |
| Minimum Hearth Area |
|
| Heat |
|
|
|
| ||||
Model |
| Log Size | Type | Front | Depth | Back | Height | Front | Depth | Back | Height | BTU/H | Output |
|
|
| |
VENTED GAS LOGS |
| FIBER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 24" | NG | 26" | 13 1/2" | 17" | 16" | 26" | 13 1/2" | 18" | 16" | 50,000 | 15,000 |
|
|
|
| |
| 24" | LP | 26" | 13 1/2" | 17" | 16" | 26" | 13 1/2" | 18" | 16" | 50,000 | 15,000 |
|
|
|
| |
| 30" | NG | 32" | 13 1/2" | 23" | 16" | 32" | 13 1/2" | 24" | 16" | 65,000 | 17,000 |
|
|
|
| |
| 30" | LP | 32" | 13 1/2" | 23" | 16" | 32" | 13 1/2" | 24" | 16" | 65,000 | 17,000 |
|
|
|
|
|
|
| Millivolt Control |
|
|
|
| |
|
| Fuel | Minimum Hearth Area |
| BTU/H |
| ||
Model | Log Size | Type | Front | Depth | Back | Height | NG | LP |
VENTED GAS LOGS | FIBER |
|
|
|
|
|
|
|
TPB18 | 18" | NG/LP | 26" | 13" | 18" | 17" | 28,000 | 28,000 |
TPB24 | 24" | NG/LP | 29" | 13" | 22 1/4" | 17" | 38,000 | 34,000 |
TPB30 | 30" | NG/LP | 33" | 13" | 25 1/4" | 17" | 38,000 | 34,000 |
*When using Colossal Series Split River Oak and Weathered Pine logs, use the burner specifications for the millivolt control for all installations when sizing for minimum hearth area.
HPBA |
Hearth, Patio & Barbecue Association |
MADE IN U.S.A.
Monessen
A Brand of Monessen Hearth Systems Co. 149 Cleveland Drive, Paris, Kentucky 40361
www.monessenhearth.com
Your Monessen Dealer:
To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. © 2008 Monessen Hearth Systems Co.
Ver.02 MON9508