Monessen Hearth HVFL18 manual Operating Instructions and Cleaning and Servicing

Page 35

OPERATING INSTRUCTIONS AND CLEANING AND SERVICING

MATCH LIGHTING INSTRUCTIONS

1.Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).

2.Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.

3.After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot access.

4.Call a qualified service technician for repair or replacement of the piezo ignitor.

CLEANING AND SERVICING

Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting.

WARNING

Turn off heater and allow to cool before cleaning. Disconnect electrical power before cleaning or servicing.

Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Refer to manual for correct log placement.

PERIODIC CLEANING - Refer to parts diagram for location of items discussed below.

Do not use cleaning fluid to clean logs or any part of heater.

Brush logs with soft bristle brush or vacuum with brush attachment.

Vacuum loose particles and dust from the front and rear burner, control and piezo covers and grate weldment.

Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush, or pipe cleaners.

Failure to keep air intake holes clean will result in sooting and poor combustion.

External case should be dusted and wiped with a wet soapy cloth.

ANNUAL CLEANING/INSPECTION - Refer to parts diagram for location of items discussed below.

Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush or pipe cleaners.

Failure to keep air intake holes clean will result in sooting and poor combustion.

Inspect and clean all burner ports.

Inspect ODS pilot for operation and accumulation of lint at air intake holes.

Verify flame pattern and log placement for proper operation.

Verify smooth and responsive ignition of main burner and rear burner.

Replace battery in remote control device.

59D1015

35

Image 35
Contents What to do if YOU Smell GAS Read and Save These InstructionsContents Owner Important Safety InformationInstaller Never connect unit to private Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started PROPANE/LPG Product Features and SpecificationsNatural GAS Thermal Generator Ignition ControlsPILOT/ODS Adequate Combustion and Ventilation AIR General Installation InformationCodes BTU/Hr = 151/2 x 12 x 8 x 1000 = 29760 BTU/Hr Hearth Minimum Dimension Fireplace and Hearth DimensionsHeight of Restriction Minimum Depth of Fireplace/Firebox Placement in a Fireplace with a Restrictive BarrierSidewall and Ceiling Clearances Clearances and Height RequirementsClearances and Height Requirements Measuring Heat Resistant Material for Mantel Example Clearances and Height RequirmentsExample Minimum Clearance above Combustible Flooring Floor ClearanceDamper Stop Installation Installing Vented ApplicationsBefore Fully Installing the Unit Before Installing the AppliancePlacing and Securing Appliance Installing Vented ApplicationsAssembly Procedure Flexible Tube Manual Shutoff Gas Supply Inlet Valve Connecting the GASManual Control Figure Checking GAS PressureOperate Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Installing T-STAT Sensor Option Sold Separately Connecting Remote ReceiverInstalling T-Stat Sensor to Hvfl Base With Screw Provided Complete MILLI-VOLT System Check Operation of Thermostat SensorChecking System Operation Placing Rock Wool Rock Wool and LOG PlacementInstalling Kentucky Stack Logs on Grate Back BurnerSee Figure LOG PlacementInstalling Back Log #1 Installing Split Maple Logs on GrateInstalling Top Right Log #5 MILLI-VOLT Control and Thermostat Control Flame AppearancePlacing the Decorative Rock Checking the Pilot FlameOperating Instructions Checking the Burner FlameWhat to do if YOU Smell GAS Operating InstructionsManual Control Lighting Instructions MILLI-VOLT Control Lighting Instructions Cleaning and Servicing Operating Instructions and Cleaning and ServicingObserved Problem Possible Cause Remedy TroubleshootingODS/pilot lights, but flame Burner Assembly Replacement PartsHVFL18 HVFL24 Replacement Parts ListKSCL18 KSCL24 KSCL30 Kentucky Stack LogsSMRL18 SMRL24 SMRL30 Split Maple LogsCarbon Monoxide Detector Requirements Special Requirements Basic Warranty Lifetime WarrantyFive Year Warranty

HVFL18 specifications

The Monessen Hearth HVFL18 represents a notable innovation in the realm of vent-free fireplaces, designed with both aesthetics and functionality in mind. This unit is an excellent choice for homeowners looking for an efficient heating solution that combines style and convenience in one compact design.

One of the standout features of the HVFL18 is its impressive heat output. This fireplace boasts a maximum of 18,000 BTUs, making it powerful enough to warm various room sizes effectively. The vent-free design allows for maximum efficiency, ensuring that all the heat generated stays within the living space. Additionally, this model uses natural gas or propane, providing flexibility for installation based on the homeowner's preferences and existing connections.

The aesthetic appeal of the Monessen Hearth HVFL18 cannot be overlooked. It is designed with a realistic flame appearance that mimics the look of a traditional wood fire. The unit comes with a variety of decorative front options, allowing homeowners to customize the overall look to fit their interior design. Whether you're aiming for a contemporary or more classic style, the HVFL18 can complement your home beautifully.

A key technology integrated into the HVFL18 is its advanced burner system. The system is designed to produce taller, flickering flames, enhancing the ambiance of a cozy fire. Along with this, the unit incorporates a built-in oxygen depletion sensor, which automatically shuts off the fireplace if oxygen levels in the room fall below a safe threshold, ensuring peace of mind for users.

Ease of use is another significant characteristic of the HVFL18. The fireplace features an intuitive electronic ignition system, which simplifies the process of starting the unit and allows for quick adjustments to the flame height. Homeowners will appreciate how easily they can obtain instant warmth with just the press of a button.

Furthermore, the Monessen Hearth HVFL18 is designed for easy installation. With no need for venting, it can be added to a variety of spaces in homes where traditional fireplaces might be impractical. The compact size makes it suitable for smaller rooms, while still delivering robust heating performance.

In conclusion, the Monessen Hearth HVFL18 combines exceptional heating power, aesthetic versatility, and state-of-the-art technology, making it a top choice for those seeking a stylish and efficient fireplace solution. Its blend of safety features, user-friendly operation, and attractive design ensures that it will enhance any home while providing warmth and comfort during colder months.