Monessen Hearth CWC400, CWC500 manual Component Description Model Number, Canada

Page 21

CWC Series Woodburning Fireplace

(Chimney Components con't.)

Component

Description

Model Number

 

 

 

Square Chase Termination

Square chimney cap used to terminate chimney

SLTS8

 

through chase. Includes adapter.

 

 

(Flashing material)

 

Adapter Kit

Required to unite 3-wall chimney with S20BR,

S20UB

 

S20BT, S20BW Traditional Top Housing

 

Chimney Support

Used to support the chimney at each 30' of

TCS8A

 

of vertical height above the hearth and

 

 

at every 6' of inclined chimney run.

 

 

Each support adds 2¹⁄" to chimney length.

 

Firestop

Required at each floor level and attic on

FS2A (8" straight flue)

 

multi-story installation.

FS6A (8" 30° inclined

 

 

flue)

Radiant Shield

Used as an alternate to FS2A firestop to

RS-8A

 

reduce the clearance from the chimney to

 

 

combustible framing. With 16" center lines.

 

Attic Insulation Shield

Used to prevent attic insulation from

FS2100-HT

(3-wall) (CF-11)

contacting the chimney system.

 

Canada

 

 

Chimney Collar Enclosure

Installs on the "over the chimney collar" of the

CCE-SK

(SK8)

fireplace; provides outside air to assist in cooling

 

 

the chimney system.

 

Attic Insulation Shield

Used to prevent insulation from coming in

AIS-SK

(SK8)

contact with the chimney system.

 

SK8 Chimney Sections

Used to build chimney systems exposed above

SK818CAN (1¹⁄' Long)

 

roof.

SK84CAN (4' Long)

45˚ Chimney Elbows

Provides 45° offset and return. For Canadian

SK845/2

 

installations only. For use with SK8 chimney only.

 

 

(Maximum use of 2, or 1 pair.)

 

Chimney Sections

Used to build chimney systems exposed above

8" flue

(3-wall)

roof.

818CAN (1¹⁄' Long)

 

 

84CAN (4' Long)

Attic Insulation Shield

Used to prevent attic insulation from

FS2100-HT

(3-wall) (CF-11)

contacting the chimney system.

 

 

 

 

87D1504

21

Image 21
Contents CWC Series Table of Contents Safety InformationCWC400 Series Woodburning Fireplace Circulating Model Front Width Back Width Depth Chase InstallationChimney Requirements Offset Installations Mounting the Fireplace Planning InformationPlanning the Chimney Run Ten Foot RuleChase Installation InstallationChimney Supports Insulating Fireplace Enclosure For Cold ClimatesInstall Variable Speed Control Install Electrical ConnectionInstallation Instructions FramingOffset Installation Straight-Up Chimney InstallationChimney Set-up Ceiling Chimney Hole Possible ObstructionsFraming the Ceiling Hole Positioning, Safety Strips Securing The FireplaceAngle of Chimney at Ceiling Size of ChimneyInstalling the Chimney System Installing Outside Air KitInstalling the Firestop Spacer Ceiling Hole Proper Firestop Spacer InstallationCanadian Requirements for Insulation Shield Continue Installing Pipe to Complete RunAdditional Ceilings Penetrating the RoofInstalling Top Housing Or Termination Install Remainder of Chimney SectionsInstalling Chimney In a Chase Cut and Frame Roof HoleSide Wall Protection From top of grille opening for circu- lating modelsTop View Minimum Wall Clearances Hearth InstallationEH2416 458 Common Materials and FactorsFireplace Top View Installing Line for Gas LogsItem/Model Number CWC400/500 Woodburning FireplaceAccessory Description Model Number AccessoriesChimney Components Component DescriptionModel Number Canada Component Description Model NumberCWC Series Woodburning Fireplace Limited Warrantycwc Series Woodburning Fireplace Mhsc