NOTES MASSACHUSETTS RESIDENTS ONLY: PLEASE READ AND FOLLOW THESE

SPECIAL REQUIREMENTS

NOTE REGARDING VENTED PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

Any residence with a direct vent product must have a CO detector installed in the residence.

Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.

In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve.

NOTE REGARDING VENT FREE PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Mas- sachusetts.

Flex line installation must not exceed 36 inches and must have a T shutoff valve.

CARBON MONOXIDE DETECTOR REQUIREMENTS

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be in- stalled.

Image 38
Contents What to do if YOU Smell GAS Models DEB20, DEB24, DEB30Read and Save These Instructions Contents Owner Important Safety InformationInstaller From Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started PROPANE/LPG Product Features and SpecificationsNatural GAS Thermal Generator Ignition ControlsPILOT/ODS Adequate Combustion and Ventilation AIR General Installation InformationCodes BTU/Hr = 151/2 x 12 x 8 x 1000 = 29760 BTU/Hr Fireplace and Hearth Dimensions Hearth Minimum DimensionPlacement in a Fireplace with a Restrictive Barrier Height of Restriction Minimum Depth of Fireplace/FireboxClearances and Height Requirements Sidewall and Ceiling ClearancesClearances and Height Requirements Measuring Heat Resistant Material for Mantel Clearances and Height Requirments HeaterExample The bottom of the mantel may project from the wall a Floor Clearance Minimum Clearance above Combustible FlooringBefore Installing the Appliance Installing Vented ApplicationsBefore Fully Installing the Unit Damper Stop InstallationPlacing and Securing Appliance Installing Vented ApplicationsAssembly Procedure Connecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveChecking GAS Pressure Manual Control FigureATE Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Connecting Remote Receiver Installing T-STAT Sensor Option Sold SeparatelyInstalling T-Stat Sensor to DEB Base With Screw Provided Complete MILLI-VOLT System Check Operation of Thermostat SensorChecking System Operation LOG Placement Installing Logs on Grate See Figures 25Checking the Pilot Flame Flame AppearancePlacing the Decorative Rock MILLI-VOLT ControlChecking the Burner Flame Operating InstructionsOperating Instructions What to do if YOU Smell GASManual Control Lighting Instructions MILLI-VOLT Control Lighting Instructions Operating Instructions and Cleaning and Servicing Cleaning and ServicingTroubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame Replacement Parts Burner AssemblyReplacement Parts List DEB20 DEB24/DEB30Logs DEB20 DEB24 DEB30Special Requirements Special Requirements Basic Warranty Lifetime WarrantyFive Year Warranty

DEB20, DEB30 specifications

Monessen has long been synonymous with quality and innovation in the hearth industry, and the Monessen Hearth DEB20 and DEB30 models are prime examples of their commitment to excellence. These direct vent gas fireplaces provide a stylish and efficient solution for heating and enhancing the ambiance of any home.

One of the standout features of both the DEB20 and DEB30 is their versatile design. Available in different sizes, the DEB20 is tailored for smaller spaces, while the DEB30 is ideal for larger areas, ensuring that homeowners can select a model that fits their specific needs. Both units are equipped with a minimalist design that allows them to seamlessly integrate into various decor styles, from modern to traditional.

Another important characteristic of the DEB series is their use of advanced technology for efficient operation. The direct vent system ensures that combustion gases are vented outside, providing a safer and cleaner indoor environment. This feature not only enhances the air quality in your home but also allows for flexible installation options, as venting can be engaged through walls or roofs.

The Monessen DEB20 and DEB30 models also boast a variety of aesthetic customizations. They come with an array of decorative options, including different media choices like glass, logs, or stones, allowing homeowners to create a truly personalized look. Optional features such as remote control operation provide additional convenience, allowing users to adjust flame height and heat output at the push of a button.

Energy efficiency is another hallmark of these fireplaces. Both the DEB20 and DEB30 are designed to maximize heat output while minimizing gas consumption, making them an economical heating solution. They also feature adjustable flame settings to meet various heating requirements, ensuring that warmth can be tailored to personal preference.

In summary, the Monessen Hearth DEB20 and DEB30 units exemplify a marriage of style and function, driven by cutting-edge technology and thoughtful design. With their efficient heating capabilities, customizable aesthetics, and safe operation, these fireplaces offer a compelling choice for anyone looking to enhance their home's warmth and charm. Whether it's for cozy family gatherings or quiet evenings, the DEB series is sure to deliver comfort and elegance.