OPERATING INSTRUCTIONS

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a

slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A.This fireplace is equipped with an ignition device which automatically lights the burner. Do not try to light by hand.

B.Before operating, smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

C.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information located above.

2.Turn off all electric power to the fireplace.

3.This fireplace is equipped with an ignition device which automatically lights the burner. Do not try to light by hand.

4.Remove the glass door.

5.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor STOP! Follow “B” in the above safety information on this label. If you don’t smell gas go to the next step.

6.Replace the glass door.

7.Turn on all electric power to the fireplace.

8.Turn the fireplace switch to the ON position.

9.If fireplace will not operate, follow instructions “To Turn Off Gas” and call your service technician or gas supplier.

FIGURE 32

TO TURN OFF GAS

1. Turn the fireplace switch to the OFF position.

3. Turn manual shut-off valve clockwise to

off.

2. Turn off all electrical power to the fireplace if service is to

Do not force.

 

be preformed.

 

 

RATING PLATE

RATING LABEL LOCATION: The rating label is located under the control panel and is chained to the fireplace.

DO NOT REMOVE.

 

 

I

 

R

 

K

 

 

 

 

 

 

 

 

TE T

 

 

 

 

 

 

 

 

N

 

E

 

 

 

 

C

 

 

 

 

 

 

CM

 

 

 

 

US

W

 

 

 

 

 

 

 

y

 

 

 

 

 

 

 

 

 

 

a

r

 

 

 

 

 

 

e

 

 

 

 

 

 

 

 

s

 

 

 

 

 

 

 

 

r

 

 

 

 

 

 

 

nock He

 

 

 

 

REFERENCE #15901

CERTIFIED UNDER : CSA 2.22-2007, ANSI 21.50-2007 VENTED GAS FIREPLACE

DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.

MODEL

CERTIFIED FOR CANADA AND USA

MODEL

GT8N

 

 

 

GT8P

 

 

 

 

(NATURAL GAS)

 

(PROPANE)

0-4500FT (0-1370m)

ALTITUDE

0-4500FT (0-1370m)

6,000 BTU/h

INPUT

6,000 BTU/h

#56

ORIFICE

#69

MANIFOLD PRESSURE: 3.5" WATER COLUMN

MANIFOLD PRESSURE: 10" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN

WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

TOP

6”

RECESSED DEPTH

7”

FLOOR

0”

VENT

1”

SIDES

0”

BACK

1 1/2”

TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING MATERIAL, SEE OWNERS MANUAL.

ELECTRICAL RATING: 115v 0.82AMP, 60HZ

VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOOR. CERTIFIED WITH THIS UNIT ONLY.

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A CERTIFIED KIT IS USED.

MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS

 

 

 

ARE 10 INCHES AND 10 FEET RESPECTIVELY.

 

 

 

MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS

SERIAL NUMBER:

GT8

W385-0381 / A

ARE 36 INCHES AND 10 FEET RESPECTIVELY.

 

 

W415-0619 / B / 03.03.08

Image 18
Contents Installation Operation Instructions Table of Contents W415-0619 / B Rates and Efficiencies General InstructionsGeneral Information Natural GAS Propane GASVenting Venting Lengths and AIR Terminal LocationsVent Installations Horizontal Vent SectionsTypical Vent Installations Horizontal Termination MIN MAXTypical Vent Installations Vertical Termination Minimum AIR Ternminal Location Clearances Installation / Framing Vertical InstallationWall and Ceiling Protection Vertical AIR Terminal Installation Using Flexible Vent ComponentsHorizontal AIR Terminal Installation Elbow SpacersMobile Home Installation Fireplace Vent ConnectionConversion Kits STAND-OFF Assembly GAS InstallationHard Wiring Connection IT is Necessary to Hard Wire this FireplaceNailing TAB Installation FramingClearances to Combustibles Without Frame InstalledFinishing Door RemovalFRAME/FRONT Installation Close the control doorAccent Glass Installation LK8 Light Installation OptionalFor Your Safety Read Before Lighting Operating InstructionsGAS Pressure Adjustment MaintenanceAdjustments Venturi AdjustmentAccessories ReplacementsReplacement Parts Flexible Vent KitsTrouble Shooting Guide Symptom Problem Test SolutionFireplace Service History
Related manuals
Manual 16 pages 5.54 Kb

GT8N, Fireplace, GT8P specifications

Napoleon Fireplaces has long been recognized as a leader in the heating industry, and the GT8N and GT8P models embody their commitment to innovation, efficiency, and style. These fireplaces are designed to provide not only warmth but also a striking aesthetic that complements various interior designs.

The GT8N and GT8P are part of Napoleon's renowned series of gas fireplaces, which focus on delivering a superior heating experience while maintaining ease of use. One of the standout features of these models is their impressive thermal efficiency, which helps to reduce energy costs while providing consistent heat output. With an energy-efficient design, the GT8N and GT8P ensure that homes remain cozy during the harshest of winters.

Both models offer a range of customizable options to suit individual preferences. The GT8N features a traditional design with classic styling, while the GT8P is more contemporary, boasting a sleek, modern look. The extensive selection of finishing materials, including various trim options and media placements, allows homeowners to customize their fireplace to seamlessly fit into their living spaces.

One of the most innovative technologies featured in the GT8N and GT8P is the advanced heat distribution system. This allows for optimal circulation of warm air throughout the room, ensuring that heat is evenly dispersed and preventing cold spots. The fireplaces are equipped with variable-speed fans that can be adjusted according to the desired heat output, providing flexibility for different situations.

Safety is a top priority in the design of the GT8N and GT8P. Both models come equipped with protective features, such as a built-in safety system that detects any irregularities in operation. Additionally, the fireplaces utilize a sealed combustion system, drawing air from outside for combustion, which minimizes the impact on indoor air quality.

Another key characteristic of the GT8N and GT8P is their ease of installation and maintenance. These fireplaces are designed to be easily integrated into existing layouts, providing versatility in home design. Moreover, the straightforward maintenance schedule, combined with high-quality materials, ensures long-lasting performance and reliability.

In summary, the Napoleon Fireplaces GT8N and GT8P represent the ideal blend of style, efficiency, and advanced technology. Whether looking for a traditional or contemporary aesthetic, these fireplaces meet the diverse needs of homeowners while providing exceptional warmth and comfort. With features that prioritize both functionality and safety, Napoleon continues to set the standard in the world of gas fireplaces.