MAINTENANCE

TURN OFF THE GAS AND UNPLUG

ELECTRICAL POWER BEFORE SERVICING

THE STOVE!

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This stove and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of com- bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1. In order to properly clean the burner and pilot assem- bly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shut- ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4. Check to see that the pilot flames are large enough to engulf the thermocouple and the thermopile on one leg and reaches toward the burner on the other leg.

5. Replace the cleaned logs.

6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/dis- tributor.

7.Check that the door gasketing is not broken or miss- ing. Replace if necessary.

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.

FIGURE 34

FIGURE 35

VENTURI ADJUSTMENT

Remove the 2 screws securing the burner. Natural gas models have air shutters set to 0.125" open (1/8"). Pro- pane models have air shutters set to 0.250" open (1/4"). After making adjustments replace the burner ensuring that the venturi tube fits over the orifice and replace the screws.

FIGURE 36

Air shutter adjustment must only be done by a

qualified gas installer!

Closing the air shutter will cause a more yellow flame, but can lead to carboning. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

ORIFICE REPLACEMENT

1.Remove the cast front and the door, see Cast Front and Glass Door Removal in the FINISHING section of this manual.

2.Remove the 2 securing screws indicated and remove the burner assembly.

3.The orifice is located on the left hand side.

4.Reinstall the burner ensuring that the venturi tube fits over the orifice and replace the screws.

Care should be taken not to damage the gas pipe. When removing and replacing the orifice, using a 9/16" socket wrench, a 7/8" back-up wrench must be used on the mani- fold, located below the housing, to ensure that the aluminium tubing does not twist or kink.

FIGURE 37

W415-0496 / B / 08.10.05

Image 21
Contents W415-0496 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Pilot Indicator Light Battery Replacement Location & ClearancesGDS20 Switches Blower InstallationAIR Terminal Installations Venting Lengths AIR Terminal Locations VentingSpecial Vent Installations Typical Vent InstallationsHorizontal Termination DefinitionsElbow Vent Length Values Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet 45V1 Vertical TerminationFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example Horizontal Installation Vertical InstallationWall and Ceiling Protection Horizontal Venting Installation Vertical Venting InstallationGAS Installation Mobile Home InstallationStove Vent Connection Restricting Vertical VentsFinishing Glass Door Installation Cast Front Installation RemovalLOG Placement Logo PlacementFor Your Safety Read Before Operating Operation / MaintenanceOperating Instructions Lighting InstructionsMaintenance AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacement Parts ReplacementsAccessories Terminal KitsW415-0496 / B Symptom Problem Test Solution Trouble Shooting GuideRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History W415-0496 / B W415-0496 / B

GDS20P, Arlington GDS20N specifications

Napoleon Fireplaces is renowned for its commitment to innovation and quality, and the Arlington GDS20N and GDS20P gas fireplaces are prime examples of this dedication. These models not only serve as functional heating solutions but also enhance the aesthetic ambiance of any room.

The Arlington GDS20N (natural gas) and GDS20P (propane) offer classic elegance combined with modern technology. One of the standout features of these fireplaces is their realistic flame presentation. Both models utilize Napoleon's advanced fuel-saving technology, which ensures an efficient burn while producing vibrant flames that mimic a traditional wood-burning fireplace.

The heat output of the GDS20 series is impressive, providing a maximum of 30,000 BTUs, which can efficiently warm larger spaces while maintaining energy efficiency. The built-in ceramic glass provides excellent heat retention and offers an unobstructed view of the flames, adding to the warmth and comfort of your home.

The design of the Arlington fireplaces includes a clean face, allowing for a minimalist aesthetic that can seamlessly fit into any interior decor style. The large viewing area and customizable media options, including glass and stones, let homeowners personalize their fireplaces to match their taste. Additionally, the option for a remote control allows for easy operation, making it more user-friendly.

Another important technological feature is the patented PHAZZER burner system. This advanced burner creates a sophisticated flame pattern and enhances the overall efficiency of the fireplace. Furthermore, the GDS20N and GDS20P fireplaces are equipped with a safety pilot system that ensures safe operation by detecting any issues in the gas supply.

Installation of the Arlington units is straightforward, thanks to their built-in convenience features such as the top or rear venting capability. This flexibility allows for various installation setups, whether in a new build or a remodel.

Lastly, homeowners can take advantage of the optional fan kits to boost heat circulation, ensuring that warmth is evenly distributed throughout the room. The Arlington GDS20N and GDS20P gas fireplaces exemplify a perfect blend of style, performance, and safety, making them an excellent choice for anyone looking to add both elegance and functionality to their living space.