20

OPERATION / MAINTENANCE

Purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing the door.

Allow several minutes (5-15) for the flame

to stabilize after ignition.

OPERATING INSTRUCTIONS

The on-off switch is located on the back of the unit at the top right corner on model GDS20.

When lit for the first time, the fireplace will emit a slight odour for a few hours.

This is a normal temporary condition caused by the cur- ing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

Simply open a window to sufficiently ventilate the room. After extended periods of non-operation such as follow- ing a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles burning off. Open a window to sufficiently ventilate the room.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: if you do not follow these instructions exactly, a fire or explosion may

result causing property damage, personal injury or loss of life.

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explo- sion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under wa- ter.

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool before attempting to re-light.

When lighting and re-lighting, the gas knob cannot be turned from PILOT to OFF unless the knob is depressed.

1.STOP! Read the safety information on the operating label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" on the op- erating label. If you don't smell gas go to the next step.

5.Find pilot located under the left side of the back log.

6.Turn gas knob counter-clockwise to pilot.

7.Depress and hold the gas knob while lighting the pilot with the push button igniter. Keep knob fully depressed for one minute, then release. If the pilot does not con- tinue to burn, repeat steps 3 through 6.

8.With the pilot lit (check pilot indicator light), turn the

gas knob counter-clockwise to on.

9.If equipped with a remote ON-OFF switch, main burner may not come on when you turn the valve to ON. The remote switch must be in the ON position to ignite the burner.

10.Turn on all electric power to the fireplace.

TO TURN OFF GAS

1.Turn off all electric power to the fireplace if service is to be performed.

2.Push in gas control knob slightly and turn clock-

wise to off. Do not force.

W415-0496 / B / 08.10.05

Image 20
Contents W415-0496 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information GDS20 Pilot Indicator Light Battery ReplacementLocation & Clearances Blower Installation SwitchesAIR Terminal Installations Venting Venting Lengths AIR Terminal LocationsTypical Vent Installations Special Vent InstallationsElbow Vent Length Values Horizontal TerminationDefinitions Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Vertical Termination 45V1Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Wall and Ceiling Protection Horizontal InstallationVertical Installation Vertical Venting Installation Horizontal Venting InstallationMobile Home Installation GAS InstallationStove Vent Connection Restricting Vertical VentsGlass Door Installation Cast Front Installation Removal FinishingLogo Placement LOG PlacementOperation / Maintenance For Your Safety Read Before OperatingOperating Instructions Lighting InstructionsAdjustments MaintenancePilot Burner Adjustment Venturi AdjustmentReplacements Replacement PartsAccessories Terminal KitsW415-0496 / B Trouble Shooting Guide Symptom Problem Test SolutionRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History W415-0496 / B W415-0496 / B

GDS20P, Arlington GDS20N specifications

Napoleon Fireplaces is renowned for its commitment to innovation and quality, and the Arlington GDS20N and GDS20P gas fireplaces are prime examples of this dedication. These models not only serve as functional heating solutions but also enhance the aesthetic ambiance of any room.

The Arlington GDS20N (natural gas) and GDS20P (propane) offer classic elegance combined with modern technology. One of the standout features of these fireplaces is their realistic flame presentation. Both models utilize Napoleon's advanced fuel-saving technology, which ensures an efficient burn while producing vibrant flames that mimic a traditional wood-burning fireplace.

The heat output of the GDS20 series is impressive, providing a maximum of 30,000 BTUs, which can efficiently warm larger spaces while maintaining energy efficiency. The built-in ceramic glass provides excellent heat retention and offers an unobstructed view of the flames, adding to the warmth and comfort of your home.

The design of the Arlington fireplaces includes a clean face, allowing for a minimalist aesthetic that can seamlessly fit into any interior decor style. The large viewing area and customizable media options, including glass and stones, let homeowners personalize their fireplaces to match their taste. Additionally, the option for a remote control allows for easy operation, making it more user-friendly.

Another important technological feature is the patented PHAZZER burner system. This advanced burner creates a sophisticated flame pattern and enhances the overall efficiency of the fireplace. Furthermore, the GDS20N and GDS20P fireplaces are equipped with a safety pilot system that ensures safe operation by detecting any issues in the gas supply.

Installation of the Arlington units is straightforward, thanks to their built-in convenience features such as the top or rear venting capability. This flexibility allows for various installation setups, whether in a new build or a remodel.

Lastly, homeowners can take advantage of the optional fan kits to boost heat circulation, ensuring that warmth is evenly distributed throughout the room. The Arlington GDS20N and GDS20P gas fireplaces exemplify a perfect blend of style, performance, and safety, making them an excellent choice for anyone looking to add both elegance and functionality to their living space.