- clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may be- come permanently marked.
White / grey film forms.
Sulphur from fuel is being depos- ited on glass, logs or combus- tion chamber surfaces.
- check that the logs are correctly positioned. - open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifice size as specified by the rating plate values.
Carbon is being de- Flame is impinging on the logs posited on glass, logs or combustion chamber.
or combustion cham- ber surfaces.
- check for chimney blockage.
- check that chimney is installed to building code.
- room is in negative pressure; increase fresh air supply.
fumes Fireplace is spilling. room,
Exhaust smelled in headaches.
Faulty valve.
- replace.
Remote wall switch wire is grounding.
- check for ground (short); repair ground or replace wire.
Remote wall switch is grounding.
- replace.
Wall switch is mounted upside down.
Remote wall switch is in off position; main burner comes on when gas knob is turned to "ON" posi- tion.
- reverse.
Flame is impinging on the logs or combustion chamber.
- ensure air shutter opening is free of lint or other obstruc- tions.
- check that the logs are correctly positioned. - open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifice size as specified by the rating plate values.
- check that the door gasketing is not broken or missing and that the seal is tight.
- check that both 4" and 7" vent liners are free of holes and well sealed at all joints.
- check that minimum rise per foor has been adhered to for any horizontal venting.
Air shutter has become blocked
Carbon is being de- posited on glass, logs or combustion chamber surfaces.
Thermopile shorting.
- clean thermopile and thermopile connection to valve.
Main burner goes out; Pilot flame is not large enough
pilot stays on. or not engulfing the thermopile.
- replace.
- turn on pilot flame. Gently twist the pilot head to improve the flame pattern aroung the thermopile.
Faulty spill switch.
Liner disconnected from insert. - re-attach liner.
Chimney is blocked
- check for chimney blockage.
- wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer. Open windows and/or doors. Start fireplace and monitor its opera- tion.
Close doors and windows and start appliances as before; room is in negative pressure; increase fresh air supply.
Chimney down-drafting
Main burner goes out; Refer to "Main burner goes out; pilot stays on" pilot goes out.
PROBLEM
SYMPTOM
TEST SOLUTION
14
Image 14
Contents GAS Inserts Table of Contents Conditions and Limitations Care of Glass and Plated General InstructionsGeneral Information Installation Wire Size MAX. Length Fibre Firebrick Panels LOG Placement FinishingOperation / Maintenance Logo PlacementMaintenance For Your Safety Read Before LightingVenturi Adjustment AdjustmentsPilot Burner Adjustment Blower SystemReplacements Replacement PartsW415-0061 / B Trouble Shooting Guide Symptom Problem Test SolutionPage Fireplace Service History W415-0061 / B

GI 3600-N, GI 3600-P specifications

The Napoleon Fireplaces GI 3600-N and GI 3600-P are cutting-edge gas insert fireplaces designed to bring warmth, comfort, and a modern aesthetic to any living space. Renowned for their efficiency and innovative features, these models set a new standard in home heating.

One of the standout features of the GI 3600-N and GI 3600-P is their impressive heat output. With a maximum input of 36,000 BTUs, they can efficiently heat areas up to 2,000 square feet, making them an ideal choice for both large and small rooms. The adjustable flame height allows users to customize the ambiance, ranging from a minimal decorative flame for a cozy evening to a roaring fire for colder nights.

These gas inserts incorporate Napoleon’s advanced modern technology, including the patented PHAZER™ log set, which is crafted from high-quality materials to provide a lifelike appearance. This technology not only enhances the visual appeal but also improves combustion efficiency. The GI 3600 series also features a highly efficient design, boasting an impressive thermal efficiency rating of up to 82%. This means less fuel consumption and lower heating bills, making it an environmentally friendly option.

Installation versatility is another significant characteristic of the GI 3600 models. The inserts can fit seamlessly into a variety of existing fireplaces, transforming dated or non-functional units into stylish and efficient heating solutions. Both models come with a choice of front designs and finishes, allowing homeowners to customize their fireplaces to match their home decor.

User-friendly controls are a hallmark of the GI 3600-N and GI 3600-P. They come equipped with a remote control option, enabling straightforward operation from the comfort of your couch. Additionally, the fireplaces feature a convenient setup for optional Wi-Fi connectivity, allowing for operation via smartphone apps for ultimate convenience.

Safety is paramount with these inserts, which include features like a safety shut-off system and a glass front that remains cool to the touch, ensuring peace of mind, especially in homes with children or pets.

In summary, the Napoleon Fireplaces GI 3600-N and GI 3600-P offer a perfect blend of style, efficiency, and advanced technology. With their impressive heating capabilities, customizable features, and focus on safety, they are an excellent addition to any home looking to enhance its aesthetic while enjoying the comforting embrace of a gas fireplace.