Napoleon Fireplaces GI 3600-N General Instructions, General Information, Care of Glass and Plated

Page 4

4

GENERAL INSTRUCTIONS

THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to re- gion and it is important to know the specifics that apply to your area,

for example: in Massachusetts State:

The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 inches.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.

In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.

Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burner before installing the door.

Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after igni- tion.

Altitudes greater than 4000ft. require a minimum vent run of 12ft.

The fireplace and its individual shutoff valve must be dis- connected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

A 1/8 inch NPT plug, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the stove.

This fireplace must be connected to any accepted lined chimney system listed to ULC-S635M (in Canada) or UL- 1777 (in USA). The venting connection must be in compli- ance with the vent manufacturers installation instructions. The draft hood must be installed so it is in the same atmo- spheric pressure zone as the combustion air inlet to the fireplace.

Provide adequate ventilation and combustion air. Pro- vide adequate accessibility clearance for servicing and operating the fireplace. Never obstruct the front open- ing of the fireplace.

This insert must be recessed into a vented noncombus- tible woodburning fireplace (prefabricated or masonry) only. The minimum fireplace size in which the heater is to be installed is:

HEIGHT 17½ inches WIDTH 25½ inches DEPTH 16½ inches The minimum distance, from the bottom of a combustible mantle projecting 6" maximum from the wall to the top of the unit, is 8".

The fireplace, when installed, must be electrically con- nected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/ NFPA 70 NATIONAL ELECTRICAL CODE in the United States. The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUAL- ITY! Maximum input is 24,000 BTU/hr for natural gas and 22,000 BTU/hr for propane. When the fireplace is installed at elevations above 4,500ft, and in the absense of specific recommendations from the local authority having jurisdic- tion, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft. Maximum out- put for natural gas is 15,900 BTU/hr and 16,000 BTU/hr for propane.

Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. This fireplace is certified for bedroom and bedsitting room installation. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.

No external electricity (110 volts or 24 volts) is required for the gas system operation.

Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected. Change in flame appearance from "HI" to "LO" is more evident in natu- ral gas than in propane.

CARE OF GLASS AND PLATED

Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer. Do not substitute materials. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required.

Do not clean glass when hot! If the glass is not kept clean permanent discolouration and / or blemishes may result.

W415-0061 / B / 01.11.05

Image 4
Contents GAS Inserts Table of Contents Conditions and Limitations General Information General InstructionsCare of Glass and Plated Installation Wire Size MAX. Length Fibre Firebrick Panels LOG Placement FinishingOperation / Maintenance Logo PlacementMaintenance For Your Safety Read Before LightingAdjustments Pilot Burner AdjustmentVenturi Adjustment Blower SystemReplacements Replacement PartsW415-0061 / B Trouble Shooting Guide Symptom Problem Test SolutionPage Fireplace Service History W415-0061 / B

GI 3600-N, GI 3600-P specifications

The Napoleon Fireplaces GI 3600-N and GI 3600-P are cutting-edge gas insert fireplaces designed to bring warmth, comfort, and a modern aesthetic to any living space. Renowned for their efficiency and innovative features, these models set a new standard in home heating.

One of the standout features of the GI 3600-N and GI 3600-P is their impressive heat output. With a maximum input of 36,000 BTUs, they can efficiently heat areas up to 2,000 square feet, making them an ideal choice for both large and small rooms. The adjustable flame height allows users to customize the ambiance, ranging from a minimal decorative flame for a cozy evening to a roaring fire for colder nights.

These gas inserts incorporate Napoleon’s advanced modern technology, including the patented PHAZER™ log set, which is crafted from high-quality materials to provide a lifelike appearance. This technology not only enhances the visual appeal but also improves combustion efficiency. The GI 3600 series also features a highly efficient design, boasting an impressive thermal efficiency rating of up to 82%. This means less fuel consumption and lower heating bills, making it an environmentally friendly option.

Installation versatility is another significant characteristic of the GI 3600 models. The inserts can fit seamlessly into a variety of existing fireplaces, transforming dated or non-functional units into stylish and efficient heating solutions. Both models come with a choice of front designs and finishes, allowing homeowners to customize their fireplaces to match their home decor.

User-friendly controls are a hallmark of the GI 3600-N and GI 3600-P. They come equipped with a remote control option, enabling straightforward operation from the comfort of your couch. Additionally, the fireplaces feature a convenient setup for optional Wi-Fi connectivity, allowing for operation via smartphone apps for ultimate convenience.

Safety is paramount with these inserts, which include features like a safety shut-off system and a glass front that remains cool to the touch, ensuring peace of mind, especially in homes with children or pets.

In summary, the Napoleon Fireplaces GI 3600-N and GI 3600-P offer a perfect blend of style, efficiency, and advanced technology. With their impressive heating capabilities, customizable features, and focus on safety, they are an excellent addition to any home looking to enhance its aesthetic while enjoying the comforting embrace of a gas fireplace.