TROUBLE SHOOTING GUIDE

BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN.

SYMPTOM

PROBLEM

TEST SOLUTION

Electrode sparks, burner

 

 

ignites, electrode

Hot and neutral wires are reversed

- Connect the hot wire to the black wire. Connect the neutral wire to

contiunes to spark for

at control module.

the white wire.

complete 7 seconds,

 

 

burner shuts down.

 

 

Main burner flame is a

 

- Remove blockage. In extremely cold conditions, ice buildup may occur

blue, lazy, transparent

Blockage in vent.

on the terminal and should be removed as required.

flame.

 

 

 

Flame length

Unit is over-fired or under-fired.

- Check pressure readings

consistently too large

 

- Outlet pressure can be checked by removing cap (A) and replacing

or too small. Carboning

 

it with a 1/8” NPT barb fitting. Next, place pressure gauge tubing

occurs.

 

over the fitting. Gauge should read 3.5” W.C. for natural gas or

 

 

10.0” W.C. for propane. AFTER TAKING PRESSURE READINGS,

 

 

BE SURE TO REPLACE CAP TO RESEAL. DO NOT OVER-TORQUE.

 

 

- Leak test with a soap and water solution.

 

 

 

 

Air shutter has become blocked.

- Ensure air shutter opening is free of lint or other obstructions.

 

 

- Open air shutter to increase the primary air.

Carbon is being

 

- Check the input rate: check the manifold pressure and orifice size as

 

specified by the rating plate values.

deposited on glass, logs

Flame is impinging on the

- Check that the door gasketing is not broken or missing and that the

or combustion chamber

seal is tight.

surfaces.

combustion chamber.

- Check that both 3” and 5” vent liners are free of holes and well

 

 

sealed at all joints.

 

 

- Check that the minimum rise per foot has been adhered to for any

 

 

horizontal venting.

 

Sulphur from fuel is being

- Clean the glass with a gas fireplace glass cleaner. DO NOT CLEAN

White / grey film forms.

deposited on glass, logs or

GLASS WHEN HOT. If deposits are not cleaned off regularly, the

 

combustion chamber surfaces.

glass may become permanently marked.

Exhaust fumes smelled in

 

- Check door seal.

Fireplace is spilling.

- Check for chimney blockage.

room, headaches.

 

- Ensure that the paint curing process is complete.

 

 

 

Thermostat or switch is defective.

- Connect a jumper wire across the wall switch terminals; if main

 

burner lights, replace switch / thermostat.

No gas to the main

 

Main burner orifice is blocked.

- Remove stoppage in orifice.

burner; switch /

thermostat is on.

Control valve faulty.

- Replace.

 

Faulty valve.

- Replace.

Burner will not light,

No gas at the burner.

- Check that the manual valve is turned on.

- Replace the valve.

ignitor sparks.

 

 

Out of propane gas.

- Fill the tank.

 

Ignitor

 

- Check the power source. (ie. fuse, circuit breaker)

will

 

- Check that the wire is connected to both the ignitor and the control

not

No spark at ignitor.

module.

spark.

- Check that the spark is not jumping to ignitor cover.

 

 

 

- Replace the wire if the wire insulation is broken or frayed.

 

 

- Replace the electrode if the ceramic insulator is cracked or broken.

 

Spark gap is incorrect.

- Spark gap should be 0.125” (1/8” approx.) from the electrode tip to the

 

sensor tip.

 

 

Remote wall switch is in

Wall switch is mounted upside

- Reverse.

“OFF” position; burner

down.

 

comes on.

 

 

Remote wall switch is grounding.

- Replace.

 

 

Remote wall switch wire is

- Check for ground (short); repair ground or replace wire.

 

grounding.

 

 

 

Faulty wire.

- Replace.

W415-0619 / A /08.09.07

Image 14
Contents Installation Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Instructions General InformationVenting Lengths VentingCare of GLASS, and Plated Parts W415-0619 / a /08.09.07 AIR Terminal Installation Installation / FramingUsing Flexible Vent Components Wall and Ceiling ProtectionFireplace Vent Connection GAS Installation FramingElectrical Connection Nailing TAB InstallationHard Wiring Connection Clearances to CombustiblesFinishing Frame InstallationLight Installation Door RemovalOperating Instructions Lighting InstructionsGAS Pressure Adjustment MaintenanceAdjustments Venturi AdjustmentAccessories ReplacementsReplacement Parts Flexible Vent KitsTrouble Shooting Guide Symptom Problem Test SolutionFireplace Service History W415-0619 / a /08.09.07
Related manuals
Manual 22 pages 19.67 Kb

GT8N, GT8P specifications

Napoleon Fireplaces has long been recognized as a leader in the heating industry, and the GT8N and GT8P models embody their commitment to innovation, efficiency, and style. These fireplaces are designed to provide not only warmth but also a striking aesthetic that complements various interior designs.

The GT8N and GT8P are part of Napoleon's renowned series of gas fireplaces, which focus on delivering a superior heating experience while maintaining ease of use. One of the standout features of these models is their impressive thermal efficiency, which helps to reduce energy costs while providing consistent heat output. With an energy-efficient design, the GT8N and GT8P ensure that homes remain cozy during the harshest of winters.

Both models offer a range of customizable options to suit individual preferences. The GT8N features a traditional design with classic styling, while the GT8P is more contemporary, boasting a sleek, modern look. The extensive selection of finishing materials, including various trim options and media placements, allows homeowners to customize their fireplace to seamlessly fit into their living spaces.

One of the most innovative technologies featured in the GT8N and GT8P is the advanced heat distribution system. This allows for optimal circulation of warm air throughout the room, ensuring that heat is evenly dispersed and preventing cold spots. The fireplaces are equipped with variable-speed fans that can be adjusted according to the desired heat output, providing flexibility for different situations.

Safety is a top priority in the design of the GT8N and GT8P. Both models come equipped with protective features, such as a built-in safety system that detects any irregularities in operation. Additionally, the fireplaces utilize a sealed combustion system, drawing air from outside for combustion, which minimizes the impact on indoor air quality.

Another key characteristic of the GT8N and GT8P is their ease of installation and maintenance. These fireplaces are designed to be easily integrated into existing layouts, providing versatility in home design. Moreover, the straightforward maintenance schedule, combined with high-quality materials, ensures long-lasting performance and reliability.

In summary, the Napoleon Fireplaces GT8N and GT8P represent the ideal blend of style, efficiency, and advanced technology. Whether looking for a traditional or contemporary aesthetic, these fireplaces meet the diverse needs of homeowners while providing exceptional warmth and comfort. With features that prioritize both functionality and safety, Napoleon continues to set the standard in the world of gas fireplaces.