Napoleon Fireplaces GI3016-N, GI3016-P manual Operation / Maintenance

Page 10

10

OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

 

FRESH AIR DAMPER SYSTEM

 

 

 

When lit for the first time, the stove will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of inter- nal paints and lubricants used in the manufacturing proc- ess and will not occur again.

Simply open a window to sufficiently ventilate the room. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room.

If your masonry fireplace is equipped with a fresh air inlet in the floor of the firebrick chamber, the insert is able to take outside air directly into the unit through an opening in its base thereby eliminating the need to use preheated room air for combustion. The flow of air may be adjusted through the use of a damper located below the louvre ac- cess door. The damper should be kept closed (pushed all the way in) when the unit is not in operation or if no outside air is available. The damper is fully open when pulled for- ward (one inch from the closed position).

FIGURE 22

Never obstruct the flow of combustion or

ventilation air.

FOR YOUR SAFETY READ BEFORE LIGHTING:

AThis stove has a pilot which must be lit by hand while following these instructions exactly.

BBefore lighting, smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

CUse only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it.

Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

DDo not use this insert if any part has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control system and any gas control touched by water.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.

LIGHTING INSTRUCTIONS

1.Stop! Read all the safety information above. When lighting and relighting, the gas knob cannot be turned from "pilot" to "off" unless the knob is depressed.

2.Turn off all electrical power to the stove.

3.Turn the gas knob clockwise to off.

4.Wait 5 minutes for any gas in the combustion cham- ber to escape. Continue to the next step if you do NOT smell any gas. If you smell gas, STOP! and follow the instructions in "What to do if You Smell Gas" listed above.

5.If the unit is equipped with a flame adjustment valve, turn clockwise to off.

6.Locate the pilot situated in front of the rear log.

7.Turn the gas knob counter-clockwise to "pi- lot" position.

8.Depress and hold the gas knob while lighting the pilot with the push button igniter. Keep the knob fully de- pressed for one (1) minute, then release. If the pilot does not continue to burn, repeat steps 3 through 7.

9.With the pilot lit, turn the gas knob counter-clock-

wise to "on" position.

10.If your insert is equipped with a flame adjustment valve, push and turn the knob to "high".

11.If your insert is equipped with a remote "on-off" switch,

the main burner may not come on when you turn the gas valve to "on" or "high". The remote switch must be in the

"on" position as well to ignite the main burner.

THERMOPIL

12.Turn on all electrical power to the insert.

PILOT BURNER

GAS VALVE

ELECTRODE

 

TO TURN OFF GAS

1. Turn off all electrical power to the unit if service is

2. Push in gas control knob slightly and turn clock-

to be performed.

wise to off.

Do not force.

W415-0171/D/01.06.04

Image 10
Contents GAS Insert Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Mantle Clearance General InstructionsGeneral Information Installation Care of GLASS, Enamelled and Plated PartsFinishing Spill SwitchOptional Brick Panel Installation Venting Action CheckLOG Placement Charcoal EmbersFlashing Surround KITS, GI-900 / GI-909 Logo PlacementFlush Glass Front KIT, GI-FF Flush Louvre KIT, GI-1LBAY Glass FRONT, GI-BF Ornamental BAY INSETS, GI-OI Ornamental Flush INSETS, GI-OI FigureBAY LOUVRES, GIB-L Operation / Maintenance Operating Instructions Fresh AIR Damper SystemBlower Replacement Installation AdjustmentsReplacements Replacement PartsW415-0171/D/01.06.04 Trouble Shooting Guide Symptom Problem Test SolutionNot Clean Glass When HOT Wolf Steel Fireplace Service History

GI3016-P, GI3016-N specifications

Napoleon Fireplaces GI3016-N and GI3016-P are modern gas fireplaces designed to enhance the warmth and ambiance of any living space. With their striking aesthetics and efficient heating capabilities, these units serve as both functional and decorative focal points in homes.

One of the most prominent features of the GI3016-N and GI3016-P is their sleek and contemporary design. The clean lines and elegant glass front allow for an unobstructed view of the dancing flames, creating an inviting atmosphere. Available in two configurations, the GI3016-N is a natural gas model, while the GI3016-P offers the convenience of propane. This flexibility makes them suitable for a variety of installations and user preferences.

These fireplaces boast advanced heating technologies, ensuring they provide maximum warmth with minimal energy consumption. The multi-function remote control allows users to adjust the flame height and control the fan speed, giving them complete command over both comfort and ambiance. The efficient heat output is further complemented by a variable-speed blower, which circulates warm air throughout the room evenly and effectively.

Efficiency is a hallmark of the GI3016-N and GI3016-P. With high-efficiency ratings, these fireplaces are designed to maximize heat while minimizing gas usage. The impressive heating capability can warm spaces of up to 1,500 square feet, making them ideal for residential settings. Additionally, the technology used in these units ensures low emissions, promoting a cleaner burning experience.

Safety is also a key consideration in the design of Napoleon Fireplaces. The units come equipped with an automatic shut-off feature and a safety screen that protects users from accidental burns. This is particularly beneficial for households with pets and children.

In terms of installation, the GI3016-N and GI3016-P are versatile, allowing for venting through the roof or side wall, which provides flexibility in positioning within the home.

Overall, Napoleon Fireplaces GI3016-N and GI3016-P exemplify quality craftsmanship combined with innovative technologies, making them a perfect addition to modern homes. With their stylish designs, efficient heating capacity, and thoughtful safety features, these fireplaces deliver both comfort and elegance, enhancing the overall living experience.