Napoleon Fireplaces BGD48P, BGD48N After Taking Pressure READINGS, be Sure to Turn Screws Clock

Page 27

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

PROBLEM

TEST SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flames are consist-

 

Unit is over-fi red or under-fi red.

- check pressure readings:

 

 

ently too large or too

 

 

Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3

 

 

small. Carboning oc-

 

 

turns and then placing pressure gauge tubing over the test point. Gauge should

 

 

curs.

 

 

read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water

 

 

 

 

 

column for propane. Check that main burner is operating on "HI".

 

 

 

 

 

Outlet pressure can be checked the same as above using screw (B). Gauge

 

 

 

 

 

should read 3.5" water column for natural gas or 10" water column for propane.

 

 

 

 

 

Check that main burner is operating on "HI".

 

 

 

 

 

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCK-

 

 

 

 

 

WISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.

 

 

 

 

 

Leak test with a soap and water solution.

 

 

 

 

 

 

 

 

 

 

Flames are very ag-

 

Door is ajar

- fit door assembly into the lower support brackets and secure the four door

 

 

gressive.

 

 

latches.

 

 

 

 

Venting action is too great.

-restrict vent exit with restrictor plate, W500-0205.

 

 

 

 

Main burner fl ame is

Blockage in vent.

- remove blockage. In really cold conditions, ice buildup may occur on the

 

a blue, lazy, transpar-

 

 

terminal and should be removed as required.

ent fl ame.

 

 

 

 

 

 

 

Incorrect installation.

- refer to Figure 23 to ensure correct location of storm collars.

 

 

 

 

Carbon is being de- posited on glass, logs or combustion cham- ber surfaces.

Air shutter has become blocked

-

ensure air shutter opening is free of lint or other obstructions.

Flame is impinging on the logs

-

check that the logs are correctly positioned.

or combustion chamber.

-

open air shutter to increase the primary air.

- check the input rate: check the manifold pressure and orifi ce size as specifi ed by the rating plate values.

- check that the door gasketing is not broken or missing and that the seal is tight.

- check that both 5" and 8" vent liners are free of holes and well sealed at all joints.

- check that minimum rise per foot has been adhered to for any horizontal venting.

White / grey film

Sulphur from fuel is being depos-

forms.

ited on glass, logs or combustion

 

chamber surfaces.

-clean the glass with a recommended gas fi replace glass cleaner. DO NOT CLEAN GLASS WHEN HOT.

If deposits are not cleaned off regularly, the glass may become permanently marked.

Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" position.

Wall switch is mounted upside

- reverse.

down

 

Remote wall switch is ground-

- replace.

ing.

 

 

 

Remote wall switch wire is

- check for ground (short); repair ground or replace wire.

grounding.

 

 

 

Faulty valve.

- replace.

W415-0326 / C / 11.23.07

Image 27
Contents W415-0326 / C $10.00 Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Down cycles are normal and are to be expected General InstructionsGeneral Information Care of GLASS, and Plated PartsInstallation Overview Venting Venting LengthsSupplier Minimum AIR Terminal Location Clearances Periscope Termination Special Vent InstallationsVertical rise is less than horizontal run Venting Application Flow ChartVertical Termination Horizontal TerminationElbow Vent Length Values When HT VTHorizontal Termination DefinitionsFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet = 10.9 + 15 = 25.9 ft Vertical Termination= .0345+90+90+90-135=5.4 = HR + HO = 5.5 + 5.4 = 10.9 ft= 19.5 + 4.5= 29 ft = .0345 + 90 + 90 + 90 135 = 5.4 ft= H R + H O = 8 + 5.4 = 13.4 ft + V T = 13.4 + 2.5 = 15.9 ftAdjustable Firestop Installation Installation Wall and Ceiling ProtectionHorizontal Installation Vertical InstallationFireplace Vent Connection Using Flexible Vent ComponentsUsing Rigid Vent Components Vertical Venting InstallationRestricting Vertical Vents Framing GAS InstallationOptional Wall Switch Installation Mobile Home InstallationFigures 35a-b Minimum Mantel and Enclosure ClearancesFinishing Nailing TAB InstallationCharcoal Embers Logo PlacementLouvre Installation Glowing EmbersOptional Blower Installation Optional FAN InstallationGD36 Thermostatic Sensor Control Open windows Operation / MaintenanceMaintenance Operating InstructionsFront Rear AdjustmentsPilot Burner Adjustment Venturi AdjustmentFlexible Vent Kits Roof Terminal Kits ReplacementsReplacement Parts AccessoriesW415-0326 / C Symptom Problem Test Solution Trouble Shooting GuideAfter Taking Pressure READINGS, be Sure to Turn Screws Clock W415-0326 / C

BGD48N, BGD48P specifications

Napoleon Fireplaces has long been a name synonymous with quality and innovation, and their BGD48N and BGD48P models are prime examples of their commitment to excellence. These fireplaces serve as a beautiful focal point in any home while providing efficient heating solutions.

The BGD48N features a classic design that echoes the elegance of traditional fireplaces. With its wide viewing area, it delivers an impressive display of flames, creating a warm and inviting atmosphere. The BGD48P, on the other hand, offers a more contemporary aesthetic, featuring clean lines and a sleek facade that complements modern decor. Both models are built with high-quality materials and craftsmanship, ensuring durability and longevity.

One of the key technologies integrated into these fireplaces is the advanced heat management system, which efficiently distributes warmth throughout the room without overheating the unit. This system uses a combination of convection and radiant heat, ensuring that the space is evenly warmed while maximizing fuel efficiency. The incorporation of a ceramic glass front allows for optimal heat retention and provides an unobstructed view of the flickering flames.

The BGD48N and BGD48P are powered by Napoleon's innovative firebox technology, which permits a variety of fuel options, including natural gas and propane. This flexibility allows homeowners to choose the heating source that best fits their needs and preferences. Additionally, these models are equipped with a powerful fan system that enhances heat circulation, thereby increasing overall efficiency.

Safety and convenience are paramount in the design of these fireplaces. Each model comes with a straightforward control panel, allowing users to easily adjust the temperature and flame height. An automatic shut-off feature ensures peace of mind, providing an added layer of safety for families. The inclusion of easy-access maintenance features also makes cleaning and upkeep a breeze.

With their combination of classic styling, modern technology, and user-friendly features, Napoleon Fireplaces BGD48N and BGD48P models stand out in the market. They offer a sophisticated heating solution that not only enhances ambiance but also improves energy efficiency. Whether you are seeking a traditional touch or a modern aesthetic, these fireplaces cater to diverse tastes, making them an excellent investment for any homeowner looking to elevate their living space.