Vermont Casting JUVSR 3096, JUVSM 3096 To Turn Off Gas To Heater, What to do if YOU Smell GAS

Page 14

Vermont Castings Jefferson Vent Free Gas Heater

Lighting And Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to "OFF".

 

 

 

 

 

PILOT

OFF

 

 

 

 

 

PILOT

 

 

1

 

 

 

t

 

F

 

 

 

 

 

 

 

 

o

 

 

 

ON

ON

P

 

 

 

F

 

 

F

 

l

 

 

 

 

 

 

i

 

2

 

 

 

 

O

 

O

 

 

F

 

 

 

 

 

 

5

 

3

 

 

FFO

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

 

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.

Turn the On/Off switch to Off position or set the

3.

Open control access panel.

 

thermostat to lowest setting.

4.

Push in gas control knob slightly and turn

2.

Turn off all electric power to the fireplace if

 

clockwise

to "OFF". Do not force.

 

service is to be performed.

5.

Close control access panel.

14

20003447

Image 14
Contents Jefferson Table Of Contents Installation & Operating Instructions Carbon Monoxide Poisoning MAY Lead to DeathJuvs Dimensions Jefferson Vent Free dimensionsMantel Mantel from Shelf Depth Stove Top Minimum Clearances to Combustible MaterialsHearth Requirements High Elevations Gas SpecificationsGas Inlet and Manifold Pressures Odor During OperationProvide for Adequate Ventilation Vent Free FeaturesFresh Air Requirements for Combustion Ventilation Unusually Tight ConstructionSupplementing ventilation air Unpack the Stove Assembly ProceduresOptional Fan Kit Installation 2960/FK28 To remove the packaged log set from the fireboxInstall ON/OFF Switch Models onlyConnect the Gas Supply Line Install the Log SetThermostat Connection optional Maximum RunInstall the Stove Front Engage with side ribsYour First Fire Flame & Temperature AdjustmentFlame Characteristics Pilot and Burner InspectionTo Turn Off Gas To Heater What to do if YOU Smell GASIgnitor Electrode sparks, but Pilot does not light TroubleshootingNo spark at pilot when Ignitor is operated Flame goes out while in operation Pilot lights but Main Burner does notMain Burner shuts off and Pilot Cleaning Procedure MaintenanceFirebox Cleaning and Inspection Care of Cast IronJefferson Vent Free Gas Heater Juvs Description JuvsFan Kits Optional AccessoriesRemote Controls Limited Lifetime Warranty Vermont Castings, Majestic Products

JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112, JUVSR 3096, JUVSM 3096, JUVSR, JUVSM, 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 specifications

Vermont Castings is renowned for its commitment to quality and craftsmanship in the realm of home heating, with its JUVSR and JUVSM series standing out as premier options for wood-burning stoves. The JUVSR and JUVSM models, including the 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, and the 3112, are designed for optimal performance, efficiency, and aesthetics, showcasing the brand's dedication to both traditional and contemporary design.

These stoves are constructed from high-quality cast iron, ensuring durability and improved heat retention. The JUVSR uses a more traditional design appeal, while the JUVSM series leans towards a sleek, modern aesthetic, catering to diverse homeowner preferences. Each model has a variety of size options, making them suitable for both small and large spaces.

One of the standout features of these models is their innovative air wash system that keeps the glass clean, providing a clear view of the beautiful fire within. This technology not only enhances the visual experience but also ensures a more efficient burn by promoting better air circulation.

The JUVSR and JUVSM stoves are equipped with Vermont's patented dual-air control system, which allows users to manage the burn rate effectively. This flexible system gives users the ability to choose between a high-output burn for quick warmth or a slower, longer-lasting heat. The JUVSR and JUVSM series also include advanced emissions technology that adheres to stringent environmental standards, making them an eco-friendly choice for heating.

Another significant characteristic of these models is their versatility in fuel choice, as they can efficiently burn seasoned wood, enhancing their functionality and appeal. The range is designed with ease of use in mind, featuring a straightforward loading door and a convenient ash pan for hassle-free cleaning and maintenance.

The Vermont Castings JUVSR and JUVSM stoves, including models like the 3095, 3096, and beyond, succeed in combining efficiency, ease of use, and aesthetic appeal. Their reliability and superior heating capabilities make them a preferred choice for environmentally conscious homeowners seeking comfort in the colder months. Ultimately, whether you opt for the JUVSR's traditional elegance or the JUVSM's modern functionality, you are investing in quality craftsmanship that stands the test of time.