Installation

SAFETY NOTICE: IF YOUR DUTCHWEST CON- VECTION HEATER IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLA- TION, OPERATION AND MAINTENANCE DIREC- TIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.

Before you begin the installation, review your plans to confirm that:

Your stove and chimney connector will be far enough from combustible material to meet all clearance require- ments.

The floor protector is large enough and is constructed properly to meet all requirements.

You have obtained all necessary permits from local authorities.

Your local building official is the final authority for ap- proving your installation as safe and for determining that it meets local and state codes.

Clearance and installation information is printed on the metal label attached to the rear of the stove. Local au- thorities generally will accept the label as evidence that, when the stove is installed according to the information on the label and in this manual, the installation meets codes and can be approved.

Codes vary in different areas, however. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed.

Important: Failure to follow these installation instruc- tions may result in a dangerous situation, including a chimney or house fire. Follow all instructions exactly, and do not allow makeshift compromises to endanger

property and personal safety.

Chimney Types

Your Dutchwest Convection Heater must be connected to a sound masonry chimney that meets local codes, a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney. Whatever kind you use, the chimney and chimney connector must be in good condition and kept clean.

Masonry Chimneys

If you use an existing masonry chimney, it must be inspected to ensure safe condition before the stove is installed. Your local professional chimney sweep, building inspector, or fire department official will be able either to make the inspection or to direct you to some- one who can.

An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chim- ney should also be examined for cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove.

Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open- ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles.

The chimney should be thoroughly cleaned before use.

A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Masonry chimneys must be lined, either with code-approved masonry or pre-cast refractory tiles, stainless steel pipe, or a code-approved, “poured-in-place” liner. The

chimney’s clean-out door must seal tightly.

Prefabricated Double-Wall

Insulated Chimney

Tile Lined

Masonry

Chimney

ST241

Fig. 2 If in sound condition and approved for use, either a masonry or a prefabricated chimney may be used.

4

7001219

Image 4
Contents Convection Heater Model Table of Contents Specifications Dutchwest, ModelChimney Types InstallationMasonry Chimneys Guidelines for Installing the Chimney Connector Two Types of ConnectorSingle-Wall Connector Prefabricated ChimneysAssembling Single-Wall Chimney Connector Double-Wall ConnectorSecuring the Connector To a Prefabricated Chimney Freestanding Installations Securing the Connector to a Masonry ChimneyFireplace Installations Above the Fireplace Fireplace Installations Through the Fireplace Wall Pass-ThroughsFireplace Installations Floor ProtectionKeep the Stove a Safe Distance From Surrounding Materials Fireplace Installation ClearancesSafe Ways to Reduce Clearances Clearance Chart Reference Diagrams Unprotected Surfaces Protected SurfacesStove and Chimney Connector Clearance Charts Unprotected Surfaces Protected Surfaces Wall Heat Shield Dimensions Unpack the Parts AssemblyAttach the Legs and Heat Shield Heater Controls and Features Air Controls OperationDamper Function Load DoorsSuccessful Wood Burning Burn Only High-Quality FuelUse the Air Control Settings That Work Best for You How to Build and Maintain a Wood Fire Loading WoodBreak-in Fires Lighting the FireReloading and Reviving the Fire Further suggestionsSafe Ash Handling Maintenance Cleaning the GlassAdjust the Door Latch Test And Repair the Door GasketsDamper Adjustment Primary Air Control AdjustmentRepair Missing Cement in Seams Avoid Damaging the Glass Door PanelCleaning the Chimney System Inspect Regularly, Clean As RequiredMaintenance Schedule Annual Spring CleaningYearly Spring Cleaning Draft Management Draft Testing Single Venting BackpuffingFuel CreosoteDutchwest Convection Heater Dutchwest Convection Heater Dutchwest Dutchwest Warranty CFM Specialty Home Products

2463 specifications

The Vermont Casting 2463 is a premium wood-burning stove that exemplifies both efficiency and craftsmanship, appealing to homeowners looking for a blend of performance and aesthetic charm. Designed with both traditional and modern aesthetics in mind, this stove fits seamlessly into a variety of home decors while providing exceptional heating capabilities.

One of the standout features of the Vermont Casting 2463 is its robust construction, which includes a heavy cast iron body. This material not only ensures longevity and durability but also provides superior heat retention, allowing the stove to radiate warmth even after the fire has diminished. The intricate design of the cast iron exterior adds an elegant touch, making it a focal point in any room.

The 2463 incorporates advanced combustion technology that enhances its efficiency. The double-combustion system ensures that smoke and particulates are burned at a higher temperature, which significantly reduces emissions and increases the overall efficiency of the burn. This not only supports eco-friendly heating but also allows users to enjoy longer burn times, minimizing the frequency of reloading the stove.

Another remarkable characteristic of the Vermont Casting 2463 is its large viewing window, which offers a captivating view of the flames, enhancing the ambiance of any space. The stove features an air wash system that keeps the glass clean, ensuring an unobstructed view of the fire while providing optimum efficiency.

Ease of use is another key aspect of the 2463 design. It includes a straightforward air control system that allows users to easily adjust the intensity of the flame and heat output to suit their preferences. The stove also features a removable ash pan, making clean-up a hassle-free task.

Furthermore, the Vermont Casting 2463 is EPA-certified, meaning it meets stringent environmental standards for emissions. This certification not only underscores the stove's commitment to sustainability but also allows homeowners to enjoy the inviting warmth of a wood fire while adhering to environmental regulations.

In summary, the Vermont Casting 2463 wood stove combines traditional craftsmanship with cutting-edge technology to create a powerful and efficient heating solution. With its durable construction, sophisticated design, user-friendly features, and eco-friendly performance, it is an excellent choice for those seeking to enhance their home's comfort and aesthetic appeal.