Vermont Casting VCBV30, VCPV30, VCPV18, VCPV10, VCPV06 Maintenance, Burner and ODS Pilot Cleaning

Page 11

Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters

Troubleshooting, continued

Problem

 

Possible Cause

 

Solution

 

 

 

 

Heater produces a clicking

1. Metal expanding and contracting.

1.

This is common with heaters. If

noise just after burner is lit or

 

 

 

noise is excessive, contact a

turned off.

 

 

 

qualified service technician.

Gas odor even when control

1. Gas leaks. Refer to front page

1.

Locate and correct leaks immedi-

knob is in OFF position.

 

Warnings.

 

ately.

 

2.

Gas control defective.

2.

Replace gas control.

Gas odor during combustion.

1. Foreign matter in gas or on burner

1.

Check gas passage way and

 

 

ports.

 

burner.

 

2.

Heater burning vapors form paint,

2.

Ventilate room, stop storing and

 

 

impurities in air.

 

using odor causing products near

 

 

 

 

heater.

 

3.

Gas leaks, refer to front page

3.

Locate and correct leaks immedi-

 

 

Warnings.

 

ately.

Heater shuts off on ODS

1. Not enough fresh air is available.

1.

Open window.

 

2.

Low gas pressure.

2.

Contact gas supplier.

 

3.

ODS pilot partially clogged.

3.

Clean the pilot.

 

 

 

 

 

Maintenance

Dust, lint, cobwebs or debris may affect heater perfor- mance. The heater draws air into it during normal operation and in the process dust, lint or debris may be drawn in also. It is important to keep the burner , gas control and combustion and circulating air passage- ways clean. Inspect or have these areas inspected annually at the beginning of the heating season by a qualified service person. Depending on the surround- ings, the room heater may require frequent cleaning due to excessive lint or debris.

Before cleaning ensure the gas supply is off and the gas control knob is in the OFF position. Make sure the heater is cool.

WARNING: Danger of bodily injury. If fan assembly accessory is used, turn off power supply at discon- nect switch or service panel before removing any access panels from heater.

Burner and ODS Pilot Cleaning

Clean the exterior with soft bristle brush, vacuum cleaner or pressurized air. Never use a wooden tooth- pick as it may break off and clog the ODS pilot or main burner port.

Use a flashlight to inspect the main burner inlet to ensure it is not blocked. If obstruction can be seen, use a metal wire coat hanger that has been straightened out.

Use a vacuum cleaner to clean the primary air openings to the main burner(s).

WARNING: Failure to keep the primary air openings to the burner(s) clean may result in sooting and property damage.

In order to clean ODS pilot orifice, use pressurized air to blow dust out. Sometimes blowing air backwards through the pilot will get rid of the accumulated dirt. If that does not work, blow out any dust through primary air openings of pilot assemblies (Daemyeong has two openings; one beneath the bimetal strip and the second one opposite from bimetal strip. Use the one wide open, do not try to lift the bimetal strip.)

Cleaning Air Passageways

and Unit Casings

Use a vacuum cleaner or pressurized air to clean the combustion and circulating air passageways and dampened cloth to clean the cabinet/casing.

11

Image 11
Contents Unvented Gas-Fired Room Heater Table of Contents General Safety InformationPiezo Ignition System Product Features Safety DeviceLocal Codes Gas Type InstallationItems Needed for Heater Installation Provide for Adequate VentilationWall Anchor Method Preparing for InstallationAttach Mounting Screws to Wall Connect to Gas Supply Floor InstallationPressure Test Gas Supply Piping System Leak Testing Heater Gas ConnectionsManual Lighting Instructions Operating InstructionsLighting Instructions To Turn Off Gas To HeaterProper pilot flame Pilot and Burner InspectionProblem Possible Cause What To Do TroubleshootingCleaning Air Passageways Unit Casings MaintenanceBurner and ODS Pilot Cleaning VCBVMN/MP Unvented Room Heater VCBVMN/MP VCPVMN/MP Unvented Room Heater VCPVMN/MP AccessoriesWarranty