Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to “OFF”.

 

 

 

 

 

PILOT

PILOT

OFF

 

 

 

 

 

 

t

 

1

F

 

 

 

 

 

 

 

 

 

lo

 

 

 

ON

ON

 

P

 

 

 

 

F

 

 

F

 

 

i

 

2

 

 

 

 

 

O

 

O

 

 

 

F

 

 

 

 

 

 

 

5

 

3

 

 

FFO

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

Euro SIT

 

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”. Do not force.

5.Close control access panel.

14

30002008

Image 14
Contents Dutchwest Table of Contents Installation & Operating Instructions Dutchwest Natural Vent Gas Heater Dimensions Dutchwest dimensionsAlcove Minimum Dimensions Parallel Installation Minimum Clearance Flue CenterlineCorner Installation Minimum Clearance Flue Centerline Ceiling ClearancesHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Venting Requirements and OptionsPassing Through a Combustible Wall or Ceiling Venting RequirementsInstall the Optional Fan Attach the fan assembly to the fan bracketVenting System Assembly Attach rheostat to left side of valveConnect the Gas Supply Line Burner Information Install ON/OFF SwitchInstall the Log Set Thermostat Connection optionalInstall the Stove Front Install the back, left and right logsPilot and Burner Inspection OperationYour First Fire Lighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionFuel Conversion Instructions Conversion PrecautionsConversion Procedure Remove pilot hood Conversion to LP Input BTU/h Air Shutter Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Air Shutter Maintenance Inspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyWiring Diagrams BLKDescription Part Number OFFDutchwest Natural Vent Gas Heater Fuel Conversion KitsFan Kits Optional Accessories AvailableRemote Controls Decorative RingsDutchwest Natural Vent Gas Heater 30002008 Limited Lifetime Warranty Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

2467, 2468 specifications

Vermont Castings is known for producing high-quality wood stoves and fireplaces, and among their popular offerings are models 2468 and 2467. These models are lauded for their efficient heating, aesthetic appeal, and innovative technology, making them a favorite for both traditionalists and modern homeowners alike.

One of the standout features of the Vermont Castings 2468 and 2467 models is their exceptional heating capacity. The 2468 can heat spaces up to 2,200 square feet, making it an ideal choice for larger homes, while the 2467 is tailored for medium-sized spaces, comfortably heating up to 1,800 square feet. This makes both models versatile options for various home sizes and layouts.

Both models utilize Vermont Castings’ patented technology, which includes a unique air wash system that keeps the glass clean, providing an unobstructed view of the flames. This enhances the cozy ambiance characteristic of a wood-burning stove, allowing homeowners to enjoy the natural beauty of the fire. Additionally, the stoves feature advanced combustion technology, allowing for a longer burn time and improved efficiency. This means fewer trips to the woodpile and less maintenance overall.

The design of the 2468 and 2467 is another highlight. Available in various finishes and styles, these stoves can complement any decor, from rustic to contemporary. The cast-iron construction not only provides durability but also helps with heat retention, ensuring warm air is released evenly throughout the space.

Furthermore, these models come equipped with user-friendly controls that allow for easy adjustment of combustion levels, ensuring optimal performance and fuel savings. The efficient burn helps in reducing emissions, making both stoves environmentally friendly options that comply with stringent EPA standards.

Homeowners can also benefit from the additional features such as a built-in blower in the 2468 that helps circulate hot air, increasing overall heating efficiency. Both models are designed for easy installation, and with an extensive warranty, Vermont Castings ensures peace of mind for users.

In conclusion, the Vermont Castings 2468 and 2467 wood stoves are emblematic of quality craftsmanship, efficient heating technology, and elegant design. They are excellent choices for those seeking a reliable and attractive heating solution in their home.