Vermont Casting 2468, 2467 manual Installation & Operating Instructions

Page 3

Dutchwest Natural Vent Gas Heater

Installation & Operating Instructions

The Dutchwest Natural Vent Room Heater, Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Al- titudes.

The installation of the Dutchwest Natural Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edi- tion and CSA B-149.1 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas at maximum input.)

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equip- ment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replace- ment of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.

The Dutchwest Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.

The Dutchwest Natural Vent Room Heater and its individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The Dutchwest Natural Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.

An accessible tap is located above the pilot/on-off knob for checking the inlet pressure.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

This appliance must be properly connected to a listed 4” (100mm) Type B venting system or to an approved masonry or factory-built chimney system. In Canada, a complete reline of Class A chimneys is required. This heater is equipped with a vent safety shutoff system.

This appliance must be properly connected to a venting system. WARNING: Operation of this heater when not con- nected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.

This appliance is approved for bedroom installations in the U.S. and Canada.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

The Dutchwest Natural Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Electri- cal Code C22.1.

Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.

WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully super- vised when they are in the same room as the appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appli- ance.

The appliance area must be kept clear and free from com- bustible materials, gasoline, and other flammable vapors and liquids.

The flow of combustion and ventilation air must not be ob- structed. The installation must include adequate accessibility and clearance for servicing and proper operation.

WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed or qualified service person.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only.

This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

*Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

30002008

3

Image 3
Contents Dutchwest Table of Contents Installation & Operating Instructions Dutchwest dimensions Dutchwest Natural Vent Gas Heater DimensionsCeiling Clearances Parallel Installation Minimum Clearance Flue CenterlineCorner Installation Minimum Clearance Flue Centerline Alcove Minimum DimensionsVenting Requirements and Options Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsVenting Requirements Passing Through a Combustible Wall or CeilingAttach the fan assembly to the fan bracket Install the Optional FanAttach rheostat to left side of valve Venting System AssemblyConnect the Gas Supply Line Thermostat Connection optional Install ON/OFF SwitchInstall the Log Set Burner InformationInstall the back, left and right logs Install the Stove FrontOperation Your First FirePilot and Burner Inspection To Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Precautions Conversion ProcedureFuel Conversion Instructions Remove pilot hood Injector Orifice Size Matrix Conversion to Natural Gas Input BTU/h Air ShutterConversion to LP Input BTU/h Air Shutter Maintenance Check the Gas Flame Regularly Gasket ReplacementStove Disassembly Inspect the Vent System AnnuallyBLK Wiring DiagramsOFF Description Part NumberFuel Conversion Kits Dutchwest Natural Vent Gas HeaterDecorative Rings Optional Accessories AvailableRemote Controls Fan KitsDutchwest Natural Vent Gas Heater 30002008 Limited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings

2467, 2468 specifications

Vermont Castings is known for producing high-quality wood stoves and fireplaces, and among their popular offerings are models 2468 and 2467. These models are lauded for their efficient heating, aesthetic appeal, and innovative technology, making them a favorite for both traditionalists and modern homeowners alike.

One of the standout features of the Vermont Castings 2468 and 2467 models is their exceptional heating capacity. The 2468 can heat spaces up to 2,200 square feet, making it an ideal choice for larger homes, while the 2467 is tailored for medium-sized spaces, comfortably heating up to 1,800 square feet. This makes both models versatile options for various home sizes and layouts.

Both models utilize Vermont Castings’ patented technology, which includes a unique air wash system that keeps the glass clean, providing an unobstructed view of the flames. This enhances the cozy ambiance characteristic of a wood-burning stove, allowing homeowners to enjoy the natural beauty of the fire. Additionally, the stoves feature advanced combustion technology, allowing for a longer burn time and improved efficiency. This means fewer trips to the woodpile and less maintenance overall.

The design of the 2468 and 2467 is another highlight. Available in various finishes and styles, these stoves can complement any decor, from rustic to contemporary. The cast-iron construction not only provides durability but also helps with heat retention, ensuring warm air is released evenly throughout the space.

Furthermore, these models come equipped with user-friendly controls that allow for easy adjustment of combustion levels, ensuring optimal performance and fuel savings. The efficient burn helps in reducing emissions, making both stoves environmentally friendly options that comply with stringent EPA standards.

Homeowners can also benefit from the additional features such as a built-in blower in the 2468 that helps circulate hot air, increasing overall heating efficiency. Both models are designed for easy installation, and with an extensive warranty, Vermont Castings ensures peace of mind for users.

In conclusion, the Vermont Castings 2468 and 2467 wood stoves are emblematic of quality craftsmanship, efficient heating technology, and elegant design. They are excellent choices for those seeking a reliable and attractive heating solution in their home.