Vermont Casting 1450 installation instructions Through the Fireplace, Wall Pass-Throughs

Page 8

Encore 1450 Non-Catalytic Woodburning Stove

The fireplace damper must be sealed to prevent room air from escaping up the flue. However, it must be possible to re-open the damper to inspect or clean the

chimney.

 

Chimney

*

Connector Shields

 

*

* Check These

Mantel

Clearances

 

 

Seal Damper

 

to Air Flow

ST244

 

Fig. 8 In this installation, the chimney connector is attached to the chimney above the fireplace opening.

Through the Fireplace

If your fireplace opening height is at least 26¹⁄₂" (675mm), you may install an Encore through the open- ing using a “positive connection” kit, available from your local dealer. These positive connection kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig. 9)

Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You’ll find the required safe clearances for Encore fire- place installations on Page 12 and Figure 16.

Floor protection requirements also apply to fireplace

installations. This information is on Page 10.

Wall Pass-Throughs

Whenever possible, design your installation so the con- nector does not pass through a combustible wall. If you are considering a wall pass-through in your installation, check with your building inspector before you begin.

Also, check with the chimney connector manufacturer for any specific requirements.

Accessories are available for use as wall pass- throughs. If using one of these, make sure it has been tested and listed for use as a wall pass-through.

Flexible Connector

Mantel Shield

Fireplace Adapter

Kit “Positive Con- nection”

ST245

Fig. 9 In this installation, the chimney connector enters the firepalce opening and then connects to the chimney.

In the United States, the National Fire Protection As- sociation (NFPA) has established guidelines for passing chimney connectors through combustible walls. Many building code inspectors follow these guidelines when approving installations.

Figure 10 shows one NFPA-recommended method. All combustible material in the wall is cut away from the single-wall connector to provide the required 12” (305mm) clearance. Any material used to close up the opening must be noncombustible.

Three other methods are also approved by the NFPA:

Using a section of double-wall chimney with a 9” (229mm) clearance to combustibles.

Placing a section of chimney connector inside a ventilated thimble, which in turn is separated from com- bustibles by 6” (152mm) of fiberglass insulating mate- rial.

Placing a section of chimney connector inside a section of 9” (230mm) diameter, solid-insulated, factory- built chimney, with 2” (50mm) of air space between the chimney section and combustibles.

In Canada, The Canadian Standards Association has established different guidelines. Figure 10 shows one method, in which all combustible material in the wall is cut away to provide the required 18” (457mm) clear- ance for the connector. The resulting space must re- main empty. A flush-mounted sheet metal cover may be used on one side only. If covers must be used on both sides, each cover must be mounted on noncombustible spacers at least 1” (25mm) clear of the wall.

8

30002425

Image 8
Contents Encore Table of Contents WelcomeEncore dimensions SpecificationsChimney Height InstallationOutside Air What Kind of Chimney to Use Masonry ChimneysPrefabricated Chimneys Chimney SizeDouble-wall Chimney Connectors Chimney Connector GuidelinesSingle-wall Chimney Connectors Securing the Single-wall Connector to a Masonry Chimney Freestanding InstallationsFireplace Installations Above the FireplaceThrough the Fireplace Wall Pass-ThroughsFloor Protection An approved wall pass-through for the United StatesFloor Protection for Fireplace Installations CanadaWall Shields Keep the Stove a Safe Distance From Surrounding MaterialsReducing Clearances Safely with Shields Chimney Connector Heat Shields Fireplace Mantel and Trim ShieldsAlcove Installations Construction RequirementsCutaway perspective of acolve installation Encore NC Clearance Chart Unprotected Surfaces Protected SurfacesEncore Clearance Diagrams BcefWall Shield Requirements for Common Installations Corner Parallel Installations Assembly Fan Kit Installation Fan installation Kit #Operation Encore NC ControlsSingle Air Control Regulates Heat Output and Burn Time Damper Directs Air Flow Within the StoveBurn Only High-Quality Wood Infrared Reflective Glass Panels For Clear Fire ViewingAndirons Help Protect the Glass Starting and Maintaining a Wood Fire Use the Air Control Settings That Work Best for YouConditioning Your Stove Refuel While the Embers Are Still Hot Add larger pieces of wood as the fire begins to burn wellAsh Removal and Disposal Draft Management Draft Testing CreosoteFuel Back-puffingMaintenance Replace the Stove Gaskets as Needed Adjust the Door LatchesTighten the Damper Handle as Needed Chimney System Creosote Adjust the Door If NecessaryAll Gasketed Construction Maintenance Schedule Stove Chimney ConnectorEncore Non-Catalytic Woodburning Stove Encore Woodburning Stove Shell Enamel Parts Encore NC Model Limited Lifetime Warranty CFM Corporation

1450 specifications

The Vermont Casting 1450 is a highly regarded wood stove model that exemplifies efficiency and craftsmanship in home heating solutions. Known for its robust construction and innovative technology, the 1450 stands out in the world of traditional wood-burning stoves.

One of the defining features of the Vermont Casting 1450 is its impressive heating capacity. Designed to efficiently heat spaces of up to 1,800 square feet, it provides a cozy warmth that is perfect for both small and medium-sized homes. This model boasts an impressive BTU output, ensuring that it can effectively maintain comfortable temperatures during even the coldest months.

A notable characteristic of the 1450 is its use of advanced catalytic technology. This feature enhances the stove's ability to burn wood more completely, leading to higher efficiency and reduced emissions. The catalytic combustor allows for a longer burn time, meaning homeowners can enjoy consistent heat with less frequent refueling. This efficiency is complemented by a large firebox, which can accommodate logs up to 20 inches long, allowing for longer burn durations between reloads.

The Vermont Casting 1450 is crafted with durability in mind, utilizing high-quality materials that ensure longevity. The cast iron construction not only enhances the stove's aesthetic appeal but also contributes to its excellent heat retention properties. This means that once the stove is heated, it continues to radiate warmth long after the fire has died down.

Another appealing aspect of the 1450 is its ease of use. Featuring adjustable air controls, homeowners can easily regulate the burn rate and heat output to suit their needs. The stove also comes with a straightforward ash removal system, making maintenance hassle-free.

The Vermont Casting 1450 combines traditional design with modern innovation. Its classic style, complete with decorative cast iron details, adds a timeless elegance to any living space. With the functionality and aesthetic appeal it offers, this model is an excellent choice for those looking to enhance their home heating experience while embracing the charm of a wood-burning stove.

Overall, the Vermont Casting 1450 is a testament to the company's dedication to quality and performance, making it a favored choice among wood stove enthusiasts.