Vermont Casting 1450 Floor Protection, An approved wall pass-through for the United States

Page 9

Wall Stud

Chimney

Connector

D

T

EFIAN

 

12” Noncombustible

Material

Floor Pro- tection

ST493

Fig. 10 An approved wall pass-through for the United States.

Your local dealer or your local building inspector can provide details for other approved methods of passing a chimney connector through a combustible wall in your area. In Canada, this type of installation must conform to CAN/CSA-B365, Installation Code for Solid Fuel Burning Appliances and Equipment.

NOTE: Do not vent your Encore into a factory-built (zero-clearance) fireplace. These appliances together with their specific chimneys are designed as a sys- tem for use as fireplaces. It may void the listing or be hazardous to adapt factory-built fireplaces for any other use.

18” (460mm) clear space all around the pipe

T

ST494

Fig. 11 An approved wall pass-through for Canada.

DO NOT CONNECT AN ENCORE TO ANY AIR DIS- TRIBUTION DUCT OR SYSTEM.

Encore 1450 Non-Catalytic Woodburning Stove

Floor Protection

A tremendous amount of heat radiates from the bottom plate of your stove. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox.

Heat protection is provided through the bottom heat shield. Spark, ember and thermal protection must be provided by a floor protector constructed with noncom- bustible material as specified.

Most installations will require the bottom heat shield be attached. Only when the stove is placed on a complete- ly noncombustible surface such as unpainted concrete over earth may it be used without the heat shield.

Even when the bottom heat shield is installed, you must provide special protection to the floor beneath. For installation with the heat shield attached, use an approved 1/2” (13 mm) noncombustible hearth pad with k = 0.84 BTU/in ft2 hr °F or an equivalent material with an R-value of at least 0.59. (Refer to “How to Determine if Alternate Floor Protection Materials are Acceptable” section) The floor protector may be covered with a decorative noncombustible material if desired. Do not obstruct the space under the heater.

Protection requirements vary somewhat between the Untied States and Canada as follows:

U. S. installations the floor protector is required under the stove and must extend at least 16” (not including the ash lip) from the front of the stove (“F”, Fig. 12), and at least 6” from the sides and rear. (“D” and “E”, Fig.

12)It must also extend under the chimney connector and 2” to either side. (“C”, Fig. 12) For the 8” (203 mm) connector, the protector must be a minimum of 12”

(305 mm) wide. For the 6” (152 mm) connector, the protector must be 10” (254 mm) wide. The protector must be centered under the connector.

To meet these requirements, a floor protector must be at least 39” wide and 45” deep.

In Canada: A noncombustible floor protector is required under the stove as well. The floor protector must extend 18” (450 mm) to the front (“F”, Fig. 12), and 8” (200 mm) from the sides and rear. (“D” and “E”, Fig. 12)

To meet these requirements, a floor protector must be at least 43” (1092 mm) wide and 49” (1245 mm) deep.

Floor protection also must extend under the chimney connector and 2” (51 mm) to either side. (“C”, Fig. 12) For the 8” (203 mm) connector, the protector must be a minimum of 12” (305 mm) wide. For the 6” (152 mm) connector, it must be at least 10” (254 mm) wide. The protector must be centered under the connector.

30002425

9

Image 9
Contents Encore Welcome Table of ContentsSpecifications Encore dimensionsInstallation Outside AirChimney Height Masonry Chimneys What Kind of Chimney to UsePrefabricated Chimneys Chimney SizeChimney Connector Guidelines Single-wall Chimney ConnectorsDouble-wall Chimney Connectors Freestanding Installations Securing the Single-wall Connector to a Masonry ChimneyFireplace Installations Above the FireplaceWall Pass-Throughs Through the FireplaceAn approved wall pass-through for the United States Floor ProtectionCanada Floor Protection for Fireplace InstallationsKeep the Stove a Safe Distance From Surrounding Materials Reducing Clearances Safely with ShieldsWall Shields Fireplace Mantel and Trim Shields Chimney Connector Heat ShieldsConstruction Requirements Alcove InstallationsCutaway perspective of acolve installation Unprotected Surfaces Protected Surfaces Encore NC Clearance ChartBcef Encore Clearance DiagramsWall Shield Requirements for Common Installations Corner Parallel Installations Assembly Fan installation Kit # Fan Kit InstallationEncore NC Controls OperationSingle Air Control Regulates Heat Output and Burn Time Damper Directs Air Flow Within the StoveInfrared Reflective Glass Panels For Clear Fire Viewing Andirons Help Protect the GlassBurn Only High-Quality Wood Use the Air Control Settings That Work Best for You Conditioning Your StoveStarting and Maintaining a Wood Fire Add larger pieces of wood as the fire begins to burn well Refuel While the Embers Are Still HotAsh Removal and Disposal Draft Management Creosote Draft TestingFuel Back-puffingMaintenance Adjust the Door Latches Tighten the Damper Handle as NeededReplace the Stove Gaskets as Needed Adjust the Door If Necessary All Gasketed ConstructionChimney System Creosote Chimney Connector Maintenance Schedule StoveEncore Non-Catalytic Woodburning Stove Encore Woodburning Stove Shell Enamel Parts Encore NC Model Limited Lifetime Warranty CFM Corporation

1450 specifications

The Vermont Casting 1450 is a highly regarded wood stove model that exemplifies efficiency and craftsmanship in home heating solutions. Known for its robust construction and innovative technology, the 1450 stands out in the world of traditional wood-burning stoves.

One of the defining features of the Vermont Casting 1450 is its impressive heating capacity. Designed to efficiently heat spaces of up to 1,800 square feet, it provides a cozy warmth that is perfect for both small and medium-sized homes. This model boasts an impressive BTU output, ensuring that it can effectively maintain comfortable temperatures during even the coldest months.

A notable characteristic of the 1450 is its use of advanced catalytic technology. This feature enhances the stove's ability to burn wood more completely, leading to higher efficiency and reduced emissions. The catalytic combustor allows for a longer burn time, meaning homeowners can enjoy consistent heat with less frequent refueling. This efficiency is complemented by a large firebox, which can accommodate logs up to 20 inches long, allowing for longer burn durations between reloads.

The Vermont Casting 1450 is crafted with durability in mind, utilizing high-quality materials that ensure longevity. The cast iron construction not only enhances the stove's aesthetic appeal but also contributes to its excellent heat retention properties. This means that once the stove is heated, it continues to radiate warmth long after the fire has died down.

Another appealing aspect of the 1450 is its ease of use. Featuring adjustable air controls, homeowners can easily regulate the burn rate and heat output to suit their needs. The stove also comes with a straightforward ash removal system, making maintenance hassle-free.

The Vermont Casting 1450 combines traditional design with modern innovation. Its classic style, complete with decorative cast iron details, adds a timeless elegance to any living space. With the functionality and aesthetic appeal it offers, this model is an excellent choice for those looking to enhance their home heating experience while embracing the charm of a wood-burning stove.

Overall, the Vermont Casting 1450 is a testament to the company's dedication to quality and performance, making it a favored choice among wood stove enthusiasts.