Vanguard Managed Solutions VP1000B installation manual TROUBLE- Shooting, See Cleaning

Page 21

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Continued

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane gas company

6.Clean ODS/pilot (see Cleaning and Mainte- nance, page 20) or replace ODS/pilot assembly

7.Replace gas regulator

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

flame goes out when

 

pressed in

 

fully

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep control knob

 

 

 

 

pressed in 30 seconds

 

3.

Manual shutoff valve

3.

Fully open manual

 

 

not fully open

 

shut-off valve

 

4.

Thermocouple connec-

4.

Hand tighten until

 

 

tion loose at control

 

snug, then tighten 1/4

 

 

valve

 

turn more

 

5.

Pilot flame not touch-

5.

A) Contact local

 

 

ing thermocouple,

 

propane gas company

 

 

which allows thermo-

 

 

 

 

couple to cool, causing

 

B) Clean ODS/pilot

 

 

pilot flame to go out.

 

(see Cleaning and

 

 

This problem could be

 

Maintenance, page 20)

 

 

caused by one or both

 

or replace ODS/pilot

 

 

of the following:

 

assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially

 

 

 

 

clogged ODS/pilot

 

 

 

6.

Thermocouple dam-

6.

Replace thermocouple

 

 

aged

 

 

 

7.

Control valve damaged

7.

Replace control valve

Continued

21

099406

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProducing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRNever install the heater A bathroom A recreational vehicle Installation ItemsCheck GAS Type Locating HeaterMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingControl knob and turn counterclockwise C-clockwise Pilot Flame Pattern Operating Heater Inspecting Burner Shutting Off Heater Shutting Off Burner Only pilot stays litCorrect Burner Flame Pattern Burner Flame PatternCleaning and Maintenance Trouble Shooting ODS/PILOT and Burner OrificeCabinet TROUBLE- Shooting See CleaningCleaning and Mainte Trouble ShootingTop Ing statement atService Hints Technical ServiceParts Under Warranty Replacement Parts Service Publications AccessoryParts Not Under Warranty Valve GA5010Heater Exploded View KEY Part Number Description QTY Parts ListKeep this Warranty Warranty Information