Vanguard Managed Solutions VP1000B installation manual Ing statement at, Top

Page 23

TROUBLE- SHOOTING

Continued

WARNING

WARNING ICON

G 001

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Heater produces a

1. Metal expanding while

1. This is common with

clicking/ticking noise

heating or contracting

most heaters. If noise is

just after burner is lit

while cooling

excessive, contact

or shut off

 

qualified service person

Heater produces unwanted odors

1.Heater burning vapors from paint, hair spray, glues, etc. See IMPOR- TANT statement above

2.Low fuel supply

3.Gas leak. See Warn- ing statement at top of page

1.Ventilate room. Stop using odor-causing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Checking Gas Connections, page 14)

Heater shuts off in use (ODS operates)

1.Not enough fresh air is available

2.Low line pressure

3.ODS/pilot is partially clogged

1.Open window and/or door for ventilation

2.Contact local propane gas company

3.Clean ODS/pilot (see Cleaning and Mainte- nance, page 20)

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position

 

top of page

 

Connections, page 14)

 

2.

Control valve defec-

2.

Replace control valve

 

 

tive

 

 

 

 

 

 

 

Gas odor during combustion

1.Foreign matter be- tween control valve and burner

2.Gas leak. See Warn- ing statement at top of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connections, page 14)

23

099406

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRLocating Heater Installation ItemsNever install the heater A bathroom A recreational vehicle Check GAS TypeMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingControl knob and turn counterclockwise C-clockwise Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice TROUBLE- Shooting See CleaningCleaning and Mainte Trouble ShootingTop Ing statement atService Hints Technical ServiceValve GA5010 Replacement Parts Service Publications AccessoryParts Under Warranty Parts Not Under WarrantyHeater Exploded View KEY Part Number Description QTY Parts ListKeep this Warranty Warranty Information