INFRARED NATURAL GAS HEATER
OPERATING
HEATER
Continued
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information | |
| on page 11, column 3. |
2. Make sure equipment shutoff valve | |
| is fully open. |
3. | Turn control knob clockwise |
| to the OFF position. |
4. | Wait five (5) minutes to clear out any |
| gas. Then smell for gas, including |
| near the floor. If you smell gas, |
| STOP! Follow “B” in the safety in- |
| formation page 11, column 3. If you |
| don’t smell gas, go to the next step. |
5. Turn control knob counterclockwise | |
| to the PILOT position. Press |
| in control knob for five (5) seconds |
| (see Figure 15). |
| Note: You may be running this |
| heater for the first time after hook- |
| ing up to gas supply. If so, the con- |
| trol knob may need to be pressed in |
| for 30 seconds. This will allow air to |
| bleed from the gas system. |
| • If control knob does not pop up |
| when released, contact a quali- |
| fied service person or gas sup- |
| plier for repairs. |
6. With control knob pressed in, push | |
| down and release ignitor button. |
| This will light pilot. The pilot is at- |
| tached to the front of burner. If |
| needed, keep pressing ignitor but- |
| ton until pilot lights. |
8.Turn control knob counterclockwise
to desired heating level. The main burner should light. Set control knob to any heat level between HI and LOW (see Figure 17).
CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.
Ignitor Button |
| Control Knob |
| PILOT | LO |
| OFF |
|
| HI |
|
IGNITOR |
|
|
Figure 15 - Control Knob In The OFF Position
Ignitor Electrode
Thermocouple
Pilot Burner
Figure 16 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2.Turn off all electric power to the ap- pliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise to the PILOT position.
THERMOSTAT
CONTROL
OPERATION
The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tempera- ture. The control knob can be set to any 2 comfort level between HI and LO.
Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.
Note: If pilot does not stay lit, refer to |
Troubleshooting, pages 14 through 16. |
Also contact a qualified service person |
or gas supplier for repairs. Until re- |
pairs are made, light pilot with match. |
To light pilot with match, see Manual |
Lighting Procedure on page 13. |
7. Keep control knob pressed in for 30 |
seconds after lighting pilot. After 30 |
seconds, release control knob. |
Note: If pilot goes out, repeat steps |
3 through 7. This heater has a safety |
interlock system. Wait one (1) minute |
Control Knob
PILOT |
|
OFF |
|
HI | LO |
PILOT | LO |
OFF |
|
HI |
|
VN1800TB
VN3000TB
before lighting pilot again. |
Figure 17 - Burner Patterns
12 | 104820 |