Vanguard Heating VN1800TB Specifications, Replacement Parts, Service Publications Technical

Page 17

OWNER’S MANUAL

SPECIFICATIONS

 

VN1800TB

VN3000TB

Btu

18,000

30,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

6" W.C.

6" W.C.

Inlet Gas Pressure* (in. of water)

 

 

Maximum

10.5"

10.5"

Minimum

7"

7"

Dimensions, Inches (H x W x D)

 

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

22

30

Shipping

27

36

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

* For purposes of input adjustment.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call DESA International’s Technical Service De- partment at 1-800-323-5190 for information.

When contacting your dealer or DESA In- ternational, have ready:

your name

your address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural gas)

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

You can also visit DESA International’s technical service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

• purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA Interna- tional, have ready:

model number of your heater

the replacement part number

104820

17

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualInfrared Natural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProducing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationLocating Heater Check GAS TypeMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Typical Inlet Pipe Diameters Connecting to GAS SupplyOperating For Your SafetyHeater Checking GAS ConnectionsLighting Instructions Operating HeaterTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingAfter ODS/pilot lights, keep control Top Replacement Parts SpecificationsService Publications Technical Service HintsVN1800TB Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListVN3000TB Parts List Equipment Shutoff Valve GA5010 AccessoriesFloor Mounting Stand Model VN1800TB GA4000B Model VN3000TB GA4010B104820 International Warranty Information