Vanguard Heating VN12A, VN6B Operating Heater, For Your Safety Read Before Lighting

Page 16

OPERATING HEATER

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING ICONG 001WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise

Clockwise

to the OFF position.

 

 

Piezo Ignitor Button

PILOT OFF

IGNITOR LOW

HIGH

Control Knob

16

Figure 15 - Control Knob In The OFF Position (Model VN12A Shown)

100845

Image 16
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemFresh AIR for Combustion and Ventilation Producing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsCheck GAS Type Installation ItemsLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply Connecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections Manual Shutoff ValveOperating Heater For Your Safety Read Before LightingLighting Instructions Pilot To Select Heating Level Burner PatternsManual Lighting Procedure Operating Heater Inspecting BurnerTo Turn OFF GAS to Appliance Pilot Flame PatternInspecting Burner Cleaning and Maintenance Burner Flame PatternODS/PILOT and Burner Orifice CabinetTrouble Shooting Observed Possible Problem Cause RemedyMaintenance, TROUBLE- ShootingLocate and correct all leaks see Checking Gas Connections, Ing statement at Technical ServiceTop Parts Not Under Warranty Parts Under WarrantyValve GA5010 Illustrated Parts Breakdown Parts ListVN6B VN12A KEY Part Number Description QTY. noWarranty Information Keep this Warranty

VN6B, VN12A specifications

The Vanguard Heating VN6B and VN12A represent cutting-edge solutions in residential heating technology. Designed to meet a variety of heating needs, these systems combine efficiency and user-friendly features, catering to an increasingly eco-conscious market.

The VN6B model is ideal for smaller homes or spaces, boasting a compact design without sacrificing power. It uses advanced condensing technology, which allows it to achieve impressive efficiency ratings. With an Annual Fuel Utilization Efficiency (AFUE) of up to 96%, the VN6B maximizes heat output while minimizing fuel consumption. This leads to significant cost savings on heating bills, making it an attractive choice for homeowners looking to upgrade their heating systems.

Meanwhile, the VN12A is built for larger areas, providing robust heating solutions for bigger residential spaces. With similar condensing technology, it features an AFUE rating that matches its smaller counterpart, ensuring that it also operates with remarkable efficiency. The VN12A is engineered with a modulating burner, which adjusts the flame size according to the building’s heating needs. This means it can operate quietly and smoothly, offering comfort without the jarring temperature fluctuations that other systems may create.

Both models incorporate innovative safety features, including a built-in flue gas condensation sensor that ensures safe operation under varied conditions. Additionally, they include a user-friendly digital thermostat, which enables precise temperature control and can be programmed for optimal efficiency. Homeowners can easily customize their heating schedule, making it convenient to maintain a comfortable living environment while also conserving energy.

Another notable characteristic of the Vanguard VN6B and VN12A is their durable construction. Made from high-quality materials, these heating units are designed to withstand wear and tear, ensuring a long lifespan with minimal maintenance. Regular maintenance reminders are a feature, making it straightforward for homeowners to keep track of service needs.

In summary, the Vanguard Heating VN6B and VN12A models stand out in the market for their exceptional efficiency, smart technologies, and user-centric features. They are excellent choices for homeowners seeking reliable and environmentally friendly heating solutions that promise comfort year-round, all while keeping energy costs low.