Vanguard Heating VN6B, VN12A installation manual Pilot

Page 17

OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 16. If you don’t smell gas, go to the next step.

5. Press in control knob, and turn counterclockwise C-clockwiseto pilot position.

Keep control knob pressed for five seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to Troubleshooting, pages 21 through

24.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19.

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 16 - Pilot

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Continued 17

100845

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProducing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRLocating Heater Installation ItemsCheck GAS Type Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsLighting Instructions For Your Safety Read Before LightingOperating Heater Pilot Burner Patterns To Select Heating LevelOperating Heater Inspecting Burner Manual Lighting ProcedureTo Turn OFF GAS to Appliance Pilot Flame PatternBurner Flame Pattern Inspecting Burner Cleaning and MaintenanceODS/PILOT and Burner Orifice CabinetObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Maintenance,Locate and correct all leaks see Checking Gas Connections, Top Technical ServiceIng statement at Valve GA5010 Parts Under WarrantyParts Not Under Warranty VN6B Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY. no VN12AKeep this Warranty Warranty Information

VN6B, VN12A specifications

The Vanguard Heating VN6B and VN12A represent cutting-edge solutions in residential heating technology. Designed to meet a variety of heating needs, these systems combine efficiency and user-friendly features, catering to an increasingly eco-conscious market.

The VN6B model is ideal for smaller homes or spaces, boasting a compact design without sacrificing power. It uses advanced condensing technology, which allows it to achieve impressive efficiency ratings. With an Annual Fuel Utilization Efficiency (AFUE) of up to 96%, the VN6B maximizes heat output while minimizing fuel consumption. This leads to significant cost savings on heating bills, making it an attractive choice for homeowners looking to upgrade their heating systems.

Meanwhile, the VN12A is built for larger areas, providing robust heating solutions for bigger residential spaces. With similar condensing technology, it features an AFUE rating that matches its smaller counterpart, ensuring that it also operates with remarkable efficiency. The VN12A is engineered with a modulating burner, which adjusts the flame size according to the building’s heating needs. This means it can operate quietly and smoothly, offering comfort without the jarring temperature fluctuations that other systems may create.

Both models incorporate innovative safety features, including a built-in flue gas condensation sensor that ensures safe operation under varied conditions. Additionally, they include a user-friendly digital thermostat, which enables precise temperature control and can be programmed for optimal efficiency. Homeowners can easily customize their heating schedule, making it convenient to maintain a comfortable living environment while also conserving energy.

Another notable characteristic of the Vanguard VN6B and VN12A is their durable construction. Made from high-quality materials, these heating units are designed to withstand wear and tear, ensuring a long lifespan with minimal maintenance. Regular maintenance reminders are a feature, making it straightforward for homeowners to keep track of service needs.

In summary, the Vanguard Heating VN6B and VN12A models stand out in the market for their exceptional efficiency, smart technologies, and user-centric features. They are excellent choices for homeowners seeking reliable and environmentally friendly heating solutions that promise comfort year-round, all while keeping energy costs low.