Vanguard Heating VN12A installation manual Parts List, Illustrated Parts Breakdown, VN6B

Page 26

PARTS LIST

VN6B

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.

KEY

PART

 

 

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

NO.

NUMBER

DESCRIPTION

QTY.

1

098304-01

Screw, #10 x 3/8"

2

14

099057-01

Pressure Tap Fitting

1

2

099467-01

Front Panel Assembly

1

15

098276-01

1/8 Pipe Plug

1

3

099318-03

Grill Guard

1

16

099468-04

Cabinet Assembly

1

4

098342-01

Grill Guard Clip

2

17

099415-01

Gas Regulator

1

5

099469-01

Reflector Assembly

1

18

098303-02

Screw, #6 x 5/16"

2

6

M15823-37

Screw Hex #8 x 1/4"

9

19

098508-01

Valve Retainer Nut

1

7

503329

ODS/Pilot Assembly

1

20

099393-01

Control Knob

1

7-1

098514-01

Thermocouple

1

21

M11084-26

Screw, #10 x 3/8"

2

7-2

098594-01

Ignitor Electrode

1

22

099818-01

Internal Tooth Washer

1

8

099884-01

Burner Assembly

1

23

097159-02

Piezo Ignitor

1

9

099056-04

Injector

1

24

098271-03

Ignitor Cable

1

10

099390-01

Tubing - Valve to burner

1

 

 

 

 

11

099387-05

Pilot Tubing - Valve to pilot

1

 

PARTS AVAILABLE - NOT SHOWN

 

12

099391-02

Tubing - Regulator to valve

1

 

 

 

 

 

 

 

 

13

100829-01

Control Valve

1

 

099395-01

Control Position Label

1

 

 

 

 

 

 

 

 

ILLUSTRATED PARTS BREAKDOWN

VN6B

23

20

16

19

22

HEATER EXPLODED VIEW

24

8

4

7

18

 

6

21

17

 

24

5

13

14

6

3

11

10 15

2

7-1

7-2

9 12

1

ODS/PILOT

GRHVP5B

GRHpv013.V

26

100845

Image 26
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Product Identification Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemUnusually Tight Construction Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsLocating Heater Installation ItemsCheck GAS Type Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply Connecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections Manual Shutoff ValveLighting Instructions For Your Safety Read Before LightingOperating Heater Pilot To Select Heating Level Burner PatternsTo Turn OFF GAS to Appliance Manual Lighting ProcedureOperating Heater Inspecting Burner Pilot Flame PatternODS/PILOT and Burner Orifice Inspecting Burner Cleaning and MaintenanceBurner Flame Pattern CabinetTrouble Shooting Observed Possible Problem Cause RemedyMaintenance, TROUBLE- ShootingLocate and correct all leaks see Checking Gas Connections, Top Technical ServiceIng statement at Valve GA5010 Parts Under WarrantyParts Not Under Warranty VN6B Parts ListIllustrated Parts Breakdown VN12A KEY Part Number Description QTY. noWarranty Information Keep this Warranty

VN6B, VN12A specifications

The Vanguard Heating VN6B and VN12A represent cutting-edge solutions in residential heating technology. Designed to meet a variety of heating needs, these systems combine efficiency and user-friendly features, catering to an increasingly eco-conscious market.

The VN6B model is ideal for smaller homes or spaces, boasting a compact design without sacrificing power. It uses advanced condensing technology, which allows it to achieve impressive efficiency ratings. With an Annual Fuel Utilization Efficiency (AFUE) of up to 96%, the VN6B maximizes heat output while minimizing fuel consumption. This leads to significant cost savings on heating bills, making it an attractive choice for homeowners looking to upgrade their heating systems.

Meanwhile, the VN12A is built for larger areas, providing robust heating solutions for bigger residential spaces. With similar condensing technology, it features an AFUE rating that matches its smaller counterpart, ensuring that it also operates with remarkable efficiency. The VN12A is engineered with a modulating burner, which adjusts the flame size according to the building’s heating needs. This means it can operate quietly and smoothly, offering comfort without the jarring temperature fluctuations that other systems may create.

Both models incorporate innovative safety features, including a built-in flue gas condensation sensor that ensures safe operation under varied conditions. Additionally, they include a user-friendly digital thermostat, which enables precise temperature control and can be programmed for optimal efficiency. Homeowners can easily customize their heating schedule, making it convenient to maintain a comfortable living environment while also conserving energy.

Another notable characteristic of the Vanguard VN6B and VN12A is their durable construction. Made from high-quality materials, these heating units are designed to withstand wear and tear, ensuring a long lifespan with minimal maintenance. Regular maintenance reminders are a feature, making it straightforward for homeowners to keep track of service needs.

In summary, the Vanguard Heating VN6B and VN12A models stand out in the market for their exceptional efficiency, smart technologies, and user-centric features. They are excellent choices for homeowners seeking reliable and environmentally friendly heating solutions that promise comfort year-round, all while keeping energy costs low.