Vanguard Heating UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER installation manual Parts List

Page 23

OWNER’S MANUAL

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.

VYD18PRA, VYD24PRA,

VYD30PRA, AND VYD36PR

KEY

 

PART NUMBER FOR

 

 

 

NO.

VYD18PRA

VYD24PRA

 

VYD30PRA

VYD36PR

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

1

105268-01

105268-02

 

105268-03

104254-01

Log, Golden Oak

1

2

103778-01

103778-01

 

103778-01

103778-01

ODS Pilot (LP)

1

3

098249-01

098249-01

 

098249-01

098249-01

ODS Nut

2

4

104422-02

103342-02

 

103342-02

103342-02

Burner Outlet Tube

1

5

098264-02

098264-02

 

098264-02

098264-02

Male Connector

1

6

102843-01

102843-01

 

102843-01

102843-01

Burner Clip

1

7

099056-19

099056-17

 

099056-17

099056-17

Burner Orifice Injector

1

8

102966-01

 

102966-01

102966-01

Upper Bracket

1

9

102980-01

102772-01

 

102772-01

102772-01

Burner

1

10

099387-13

099387-09

 

099387-09

099387-09

Pilot Tube

1

11

103781-02

103781-02

 

103781-02

103781-02

Gas Control Valve

1

12

103345-02

103345-01

 

103345-01

103345-01

Lower Bracket

1

13

M11084-38

M11084-38

 

M11084-38

M11084-38

Screw, #8 x .38

7

14

104384-01

102775-06CK

 

102775-08CK

102775-08CK

Painted Base Assy

1

15

098271-07

098271-07

 

098271-07

098271-07

Ignitor Cable

1

16

102445-01

102445-01

 

102445-01

102445-01

Piezo Ignitor

1

17

103587-02

103587-02

 

103587-02

103587-02

Plate, Switch

1

18

104099-01

104099-01

 

104099-01

104099-01

Heat Shield

1

19

098304-01

098304-01

 

098304-01

098304-01

Screw

2

20

103784-02

103784-02

 

103784-02

103784-02

Flame Adjustment Knob

1

21

103784-01

103784-01

 

103784-01

103784-01

Off-Pilot-On Knob

1

22

M12461-26

M12461-26

 

M12461-26

M12461-26

Screw, Hex Slt Wsr

 

 

 

 

 

 

 

10-32 x .38

4

23

103284-02

103284-02

 

103284-02

103284-02

Wiring Harness

 

24

099998-01

099998-01

 

099998-01

099998-01

Switch

1

 

 

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

 

 

 

 

100563-01

100563-01

 

100563-01

100563-01

Warning Plate

1

 

103877-01

103877-01

 

103877-01

103877-01

Lighting Instructions

 

 

 

 

 

 

 

Plate

1

 

100565-01

100565-01

 

100565-01

100565-01

Warning Plate Fastener

1

 

100693-01

100639-01

 

100639-01

100639-01

Caution Decal

1

 

101137-02

101137-02

 

101137-02

101137-02

Hardware Kit

1

 

104310-01

104310-08

 

104310-08

104310-08

Information Video

1

 

GA6060

GA6060

 

GA6060

GA6060

Lava Rock

1

 

 

 

 

 

 

 

 

105274

23

Image 23
Contents Save this manual for future reference OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS 18, 24, 30, and 36 Remote Ready ModelVanguard FLAME-MAX Unvented PROPANE/LP GAS LOG Heater Safety InformationProduct Identification Local Codes Unpacking Product FeaturesRemote Control Accessories Confined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingCheck GAS Type InstallationMinimum Fireplace Clearance to Combustible Materials LOG Sizing RequirementsMinimum Noncombustible Material Clearances If Using MantelIf Not Using Mantel Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When using a HoodMantel Clearances Floor ClearancesChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Attaching Flexible Gas Hose to Heater Installation Items NeededExternal regulator not supplied Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Checking GAS ConnectionsPlace lava rock around base of heater Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Burner Primary AIR Holes OperatingInspecting Burners Pilot Flame PatternLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Top Gas leak. See Warning statement atIllustrated Parts Breakdown VYD18PRA, VYD24PRA VYD30PRA, and VYD36PR Parts ListService Hints Wiring DiagramSpecifications Replacement PartsAccessories International Warranty Information

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER specifications

The Vanguard Heating Unvented (Vent-Free) Propane/LP Gas Log Heater is a remarkable home heating solution that combines efficiency, convenience, and aesthetic appeal. Designed to deliver warmth without the need for traditional venting, this heater stands out for its innovative technology and user-friendly features.

One of the main attractions of the Vanguard unvented gas log heater is its ability to provide consistent heat while conserving energy. The unit operates using propane or LP gas, making it an excellent option for homes without access to natural gas. With a high heat output, it efficiently warms spaces while potentially reducing heating costs compared to conventional systems.

The design of the Vanguard heater incorporates advanced catalyst technology, which ensures that combustion is clean and efficient. This technology minimizes emissions, making it an environmentally friendly choice for homeowners concerned about their carbon footprint. Furthermore, the heater is equipped with an oxygen depletion sensor (ODS) that automatically shuts off the gas supply if oxygen levels fall below safe thresholds, ensuring peace of mind for users.

Aesthetically, the Vanguard model features realistic log designs that replicate the appearance of a traditional wood-burning fireplace. This adds warmth and charm to any living space. The adjustable flame height allows users to customize their heating experience to suit their needs or mood. The controls are designed for ease of use, allowing for simple operation whether the heater is used for primary warmth or supplemental heat.

Safety is a key characteristic of the Vanguard unvented gas log heater. Besides the ODS mentioned earlier, the heater is built with durable materials that ensure longevity and reliability. It can be installed in various locations, including bedrooms and living rooms, as long as the manufacturer's guidelines are followed.

Installation of the Vanguard heater is relatively straightforward, requiring minimal modifications to existing spaces. This flexibility makes it appealing for both new constructions and retrofits. Additionally, the absence of venting means that installation costs are often lower than with vented units.

In summary, the Vanguard Heating Unvented Propane/LP Gas Log Heater combines advanced technology, stylish design, and crucial safety features, making it a viable choice for those seeking efficient indoor heating solutions. Its ease of installation and operation further enhances its attractiveness to modern homeowners. Whether for cozy family gatherings or quiet evenings at home, this heater is an excellent investment in comfort and warmth.