Vanguard Heating UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER Product Identification

Page 3

OWNER’S MANUAL

PRODUCT

IDENTIFICATION

Flame-Max®

Golden Oak Logs

One Piece

Log Set

Optional

Remote

Control

Piezo

Ignitor

Optional Selector

SwitchFlameBase Assembly

Adjustment

Knob

Control Knob

Figure 1 - Product Identification

LOCAL CODES

UNPACKING

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANS Z21.60) product by opening the flue damper (non-thermostat operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

CAUTION: Do not remove the metal Data Plates from the grate assembly. The Data Plates contain important product information.

1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by the burner. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

REMOTE CONTROL ACCESSORIES

There are four optional remote controls that can be purchased separately for this log heater:

wall switch

wall thermostat

hand held ON/OFF remote

hand held thermostat remote

See Accessories, page 25.

The wall thermostat or hand-held thermo- stat may not be used where vented decora- tive listing is required.

105274

3

Image 3
Contents Save this manual for future reference OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS 18, 24, 30, and 36 Remote Ready ModelVanguard FLAME-MAX Unvented PROPANE/LP GAS LOG Heater Safety InformationLocal Codes Unpacking Product Features Remote Control AccessoriesProduct Identification Confined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingCheck GAS Type InstallationMinimum Fireplace Clearance to Combustible Materials LOG Sizing RequirementsIf Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When using a HoodMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyChimney Minimum Permanent Height ft Flue Opening sq. ins Attaching Flexible Gas Hose to Heater Installation Items NeededExternal regulator not supplied Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Checking GAS ConnectionsPlace lava rock around base of heater Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Burner Primary AIR Holes OperatingInspecting Burners Pilot Flame PatternCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Top Gas leak. See Warning statement atIllustrated Parts Breakdown VYD18PRA, VYD24PRA VYD30PRA, and VYD36PR Parts ListService Hints Wiring DiagramSpecifications Replacement PartsAccessories International Warranty Information

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER specifications

The Vanguard Heating Unvented (Vent-Free) Propane/LP Gas Log Heater is a remarkable home heating solution that combines efficiency, convenience, and aesthetic appeal. Designed to deliver warmth without the need for traditional venting, this heater stands out for its innovative technology and user-friendly features.

One of the main attractions of the Vanguard unvented gas log heater is its ability to provide consistent heat while conserving energy. The unit operates using propane or LP gas, making it an excellent option for homes without access to natural gas. With a high heat output, it efficiently warms spaces while potentially reducing heating costs compared to conventional systems.

The design of the Vanguard heater incorporates advanced catalyst technology, which ensures that combustion is clean and efficient. This technology minimizes emissions, making it an environmentally friendly choice for homeowners concerned about their carbon footprint. Furthermore, the heater is equipped with an oxygen depletion sensor (ODS) that automatically shuts off the gas supply if oxygen levels fall below safe thresholds, ensuring peace of mind for users.

Aesthetically, the Vanguard model features realistic log designs that replicate the appearance of a traditional wood-burning fireplace. This adds warmth and charm to any living space. The adjustable flame height allows users to customize their heating experience to suit their needs or mood. The controls are designed for ease of use, allowing for simple operation whether the heater is used for primary warmth or supplemental heat.

Safety is a key characteristic of the Vanguard unvented gas log heater. Besides the ODS mentioned earlier, the heater is built with durable materials that ensure longevity and reliability. It can be installed in various locations, including bedrooms and living rooms, as long as the manufacturer's guidelines are followed.

Installation of the Vanguard heater is relatively straightforward, requiring minimal modifications to existing spaces. This flexibility makes it appealing for both new constructions and retrofits. Additionally, the absence of venting means that installation costs are often lower than with vented units.

In summary, the Vanguard Heating Unvented Propane/LP Gas Log Heater combines advanced technology, stylish design, and crucial safety features, making it a viable choice for those seeking efficient indoor heating solutions. Its ease of installation and operation further enhances its attractiveness to modern homeowners. Whether for cozy family gatherings or quiet evenings at home, this heater is an excellent investment in comfort and warmth.