Vanguard Heating GVB50P, GVB35P Ordering Replacement, Centrals, Parts Under Warranty

Page 34

ORDERING

Note: Use only original replacement parts. This will protect your warranty cover-

REPLACEMENT

age for parts replaced under warranty.

Parts Under Warranty

PARTS

Contact Vanguard dealer or call DESA International’s Technical Service Depart-

ment at 1-800-323-5190.

When calling DESA International, have ready

your name

your address

model number of your heater

how heater was malfunctioning

type of gas used (propane or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact Vanguard dealer. If they can’t supply original replacement part(s), either contact your nearest Parts Central (below) or call DESA International’s Parts Department at 1-800-972-7879.

 

 

When calling DESA International, have ready

 

 

 

• model number of your heater

 

 

PARTS

• the replacement part number

 

 

These Parts Centrals are privately owned businesses. They have agreed to support

 

 

 

CENTRALS

our customer’s needs by providing original replacement parts and accessories. For

 

certain parts, some Parts Centrals may refer you to a dealer in your area. When

 

 

calling a Parts Central, ask for the Parts Department.

 

 

 

Howard Industries

Washer Equipment Co.

Warmer Image/Halco

 

 

1514 South Maple Ave.

1715 Main Street

Enterprises

 

 

Los Angeles, CA 90015

Kansas City, MO 64108

208 Carter Dr., Unit 21

 

 

213-747-5121

KS, MO, AR

West Chester, PA 19382

 

 

Victor Manufacturing

816-842-3911

215-696-2670

 

 

 

1-800-368-0803

 

 

42 Rumsey Road

Controls, Inc.

 

 

 

 

 

E. Hartford, CT 06108

6820 Glenwood Ave.

LaPorte’s Parts & Service

 

 

NY, NJ, DE, PA, MD

Raleigh, NC 27612

2444 North 5th Street

 

 

203-289-4223

NC, SC, VA, MD

Hartsville, SC 29550

 

 

Controlled Engineering

919-787-2242

803-879-3009

 

 

1-800-334-5886

 

 

 

299 Roosevelt Road

Cans Unlimited, Inc.

 

 

Taratin Tank Co.

 

 

Glen Ellyn, IL 60137

P. O. Box 645

 

 

708-469-7300

P.O. Box 6129

Taylor, SC 29687

 

 

Portable Heater Parts

Freehold, NJ 07728

All States

 

 

908-780-9340

 

 

803-879-3009

 

 

342 N. County Rd 400E

 

 

800-922-0724

 

 

1-800-845-5301

 

 

Valparaiso, IN 46383

 

 

 

 

 

East Coast Energy

 

 

 

All States

Dealers LP Equip. Co.

 

 

707 Broadway

 

 

219-462-7441

P.O. Box 341145

 

 

W. Long Branch, NJ 07764

 

 

1-800-362-6951

Bartlett, TN 38184

 

 

908-870-8809

 

 

FBD

Al, TN

 

 

1-800-755-8809

 

 

901-386-8780

 

 

601 Hope Street

 

 

ATP Services

 

 

800-428-8902

 

 

Bowling Green, KY 42101

 

 

990 Avenue of Americas

 

 

 

502-796-8406

Capitol Hydronic Supply

 

 

New York, NY 10018

 

 

800-654-8534

104 West Jefferson Street

 

 

212-967-6255

 

 

American Air Dist.

Falls Church, VA 22046

 

 

Dayton Hardware

 

 

703-416-8555

 

 

537 W. 62nd Street

 

 

P. O. Box 275

 

 

 

 

 

Shreveport, LA 71108

Tuco Industrial Products

 

 

North Dayton Station

 

 

318-861-0634

P.O. Box 5076

 

 

Dayton, OH 45404

 

 

 

Lynwood, WA 98046

 

 

Master Service Center

All States

 

 

206-743-9533

 

 

1184 Wilson

513-258-3721

 

 

1-800-735-1268

 

 

Grand Rapids, MI 49504

OH only 1-800-762-3426

 

 

616-791-4760

Central Air Supply

Auer Steel & Heating Supply

 

 

800-446-1446

424 North Rockwell

2935 W. Silver Spring Dr.

 

 

 

Oklahoma City, OK 73127

Milwaukee, WI 53209

34

 

 

 

 

 

 

405-495-0014

414-463-1234

 

 

 

 

 

100354

Image 34
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Electrical shock, and carbon monoxide poisoning SafetyInformation Carbon monoxide poisoning may lead to deathSafety Information Product Identification Unpacking FeaturesInstalling Heater ProductInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Qualified service person must connect heater to gas InstallingConnecting to GAS Supply Supply. Follow all local codesGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Glass Panel Removing Lower Front Access PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location CombustionVentilation Draft Hood Spillage TestFresh AIR for Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 17 to make sure fresh air ventilation is adequateOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burner Only pilot stays litPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Son should service and repair heater and venting systemCleaning and Mainte TroubleTROUBLE- Shooting Do not try to light any appliance If you smell gasShut off gas supply Gas leak. See WarningService Procedures Removing Control Valve and Burner TubeRemoving Burner Changing Burner Orifice Orifice Location 35,000 BTU/Hr Burner ShownSpecifications Technical ServiceService Hints 35,000 BTU/HrParts Not Under Warranty Ordering ReplacementParts Under Warranty PartsAccessories Valve GA5010Illustrated Parts List QTY Cabinet Assembly 100354 Warranty Information International

GVB50P, GVB35P specifications

The Vanguard Heating GVB35P and GVB50P models represent a significant advancement in home heating technology, designed to cater to the needs of residential spaces with varying heating demands. These gas-fired boilers not only ensure optimal warmth but also focus on energy efficiency and user-friendly operation.

One of the main features of the GVB35P and GVB50P is their impressive heating capacity. The GVB35P is suitable for smaller homes or apartments, with a heating output of around 35,000 BTU, while the GVB50P is designed for larger spaces, offering an impressive 50,000 BTU. This versatility allows homeowners to select the most appropriate model for their specific requirements, ensuring efficient heating without unnecessary energy consumption.

Both models incorporate advanced condensing technology, which significantly enhances their efficiency ratings. By capturing and reusing heat that typically escapes through the flue in traditional boilers, the GVB35P and GVB50P achieve high Annual Fuel Utilization Efficiency (AFUE) ratings. This not only reduces the overall energy bill but also contributes to a lower carbon footprint, making these models an environmentally conscious choice.

The construction of the GVB35P and GVB50P features robust, durable materials aimed at maximizing longevity and reliability. The heat exchangers are designed to withstand high temperatures and pressures, ensuring safety and durability. Additionally, these models are equipped with a modulating gas burner, which allows for precise temperature control and minimizes energy wastage during operation.

User convenience is further enhanced by the inclusion of a built-in digital control system. This allows homeowners to easily adjust the heating settings remotely, ensuring homes are warm upon arrival without requiring constant manual input. Moreover, the low maintenance requirements of these models make them appealing to busy homeowners, as regular service intervals are reduced.

In summary, the Vanguard Heating GVB35P and GVB50P models combine advanced technology, high efficiency, and user-friendly features to deliver exceptional heating performance. Their durable construction, energy-saving capabilities, and modern controls make them an excellent choice for homeowners looking to enhance comfort while minimizing environmental impact. Whether for a small apartment or a larger home, these boilers stand out as a reliable heating solution.