Vanguard Heating VMH26NR installation manual Ventilation AIR, Ventilation Air From Inside Building

Page 7

OWNER’S MANUAL

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

remove door into adjoining room (see op- tion 3, Figure 4). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

12"

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel

104325

7

Image 7
Contents What to do if YOU Smell GAS VENT-FREE Natural GASCompact Classic Hearth Fireplace Safety InformationLocal Codes Product FeaturesRemote Control Accessories Product IdentificationAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly Installing Blower Accessory GA3400TInstalling Blower Assembly Follow steps 2 through 6 in Installing Blower Assembly, For Built-In InstallationExtension Cord Connecting to GAS SupplyAttaching Wood Base to Solid Floor Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Optional Wall Mounted Thermostat GWMT1 Optional Wireless HAND- Held Remote Control AccessoriesInstalling Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitThermostat Base Terminals W and R Optional Wall Switch GWMS2Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting Procedure Optional Remote OperationGWMT1 Wall Mounted Thermostat Optional GWMS2 Wall Mounted Switch OptionalOperating Blower Pilot Flame Pattern Inspecting BurnerBurner Flame Pattern Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Top Wiring Diagram Cleaning and MaintenanceService Hints Technical ServiceAccessories Replacement Parts SpecificationsVMH26NR4 Illustrated Parts BreakdownVMH26NR Parts ListWarranty Information

VMH26NR specifications

The Vanguard Heating VMH26NR is an innovative heating solution designed to provide efficient warmth while prioritizing energy savings and user comfort. With its sleek design and advanced technologies, the VMH26NR stands out in the crowded market of heating appliances.

One of the main features of the VMH26NR is its powerful heating capability. Equipped with a robust heating element, it can produce a significant amount of warmth quickly, making it ideal for medium to large spaces. Whether you are heating a living room, office, or workshop, the VMH26NR ensures that you stay comfortable during the colder months.

Efficiency is another hallmark of this model. The VMH26NR employs cutting-edge energy-saving technologies that optimize power consumption. This not only reduces energy bills but also lessens the environmental impact associated with conventional heating methods. Users can enjoy a warm atmosphere while being conscious of their carbon footprint.

The VMH26NR also features a user-friendly digital thermostat, which allows for precise temperature control. Users can easily adjust the settings to their comfort level, ensuring that the space remains at an ideal temperature without unnecessary energy expenditure. The digital display provides clear readings, making it easy to monitor performance and settings.

For added convenience, the unit comes with a programmable timer, allowing users to schedule the heating periods according to their routines. This feature is particularly beneficial for those who want the heater to operate only when needed, further enhancing energy efficiency and user convenience.

Safety is a top priority in the design of the VMH26NR. It is equipped with several safety features, including overheat protection and a tip-over switch, which automatically shuts off the unit in case of accidents. This ensures peace of mind, especially in households with pets or young children.

The Vanguard Heating VMH26NR also boasts a compact, portable design that makes it easy to move from room to room. Its lightweight construction and built-in handles provide added portability, allowing users to enjoy warmth wherever it is needed most.

In conclusion, the Vanguard Heating VMH26NR is a powerful, efficient, and user-friendly heating solution. Its advanced features, safety mechanisms, and adaptability make it an excellent choice for anyone looking to enhance their comfort during the chilly seasons. Whether you are a homeowner or a business owner, the VMH26NR promises to deliver reliable performance and satisfaction.