Vanguard Heating VYGF33NRA installation manual Parts List

Page 27

OWNER’S MANUAL

PARTS LIST

FIREPLACE

VYGF33NRA

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

KEY

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

101357-01

Top Outer Casing

1

2

103207-01

Outer Casing

1

3

102758-02CK

Right Front Side

1

4

102759-02CK

Left Front Side

1

5

098304-01

Phillips Pan Head Screw, #10

9

6

104239-01CK

Top Front Louver

1

7

101712-02

Firebox Hood

1

8

101348-01

Firebox Support

2

9

099230-02

Shoulder Screw

4

10

101872-03

Firebox Top

1

11

101346-01CK

Outer Base

1

12

101838-03CJ

Firebox Wrapper

1

13

101514-01CK

Cover

1

14

M11084-26

Hex Screw, #10

45

15

104242-01CK

Bottom Louvered Door

1

16

101727-03

Screen Assembly

1

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

101386-02

Louvered Door Hinge

2

 

101784-01

Magnet Catch

2

 

102307-01

Strike Plate

2

 

 

 

 

105269

27

Image 27
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented Natural GAS Fireplace Safety InformationProduct Identification Local CodesUnpacking AIR for Combustion and Ventilation Product FeaturesAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeConventional Fireplace Installation Installation ClearancesLocation of Nailing Flanges BUILT-IN Fireplace InstallationInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Installing One Piece Log Set Installing LogsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Burner Primary AIR Holes Inspecting BurnersOptional Blower Operation Pilot Flame PatternObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Wiring Diagram Replacement PartsSpecifications Service HintsCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Accessories Firebox Brick Liner G8000 Series WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Brass Trim Accessory GA6090Remote Ready Model VYGF33NRA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFireplace VYGF33NRA Parts List Warranty Information

VYGF33NRA specifications

The Vanguard Heating VYGF33NRA is a highly efficient heating solution designed to provide reliable warmth for residential and commercial spaces. This natural gas-fired unit is known for its robust construction and advanced technology, ensuring it meets the needs of various applications while delivering optimal performance.

One of the standout features of the VYGF33NRA is its impressive heating capacity. With an output of 33,000 BTUs, this heater can effectively warm large areas, making it suitable for homes, workshops, and offices. It is particularly advantageous for spaces that demand consistent and reliable heating throughout colder months.

Efficiency is a hallmark of the Vanguard VYGF33NRA. It boasts a remarkable AFUE (Annual Fuel Utilization Efficiency) rating, which signifies its ability to convert a high percentage of gas into usable heat. This feature not only supports energy conservation but also helps reduce overall heating costs, making it an eco-friendly choice for consumers.

The VYGF33NRA is equipped with a state-of-the-art electronic ignition system, ensuring quick and reliable starts. This system decreases the likelihood of pilot light issues and enhances safety, providing peace of mind for users. Additionally, the built-in safety features, including flame rollout switches and limit switches, help guard against overheating and system malfunctions.

Durability is another key characteristic of this heating unit. The VYGF33NRA features a rugged design with high-quality materials, ensuring it can withstand the rigors of daily use. Its compact footprint allows for flexible installation, enabling it to fit comfortably in tighter spaces without compromising on performance.

The Vanguard Heating VYGF33NRA also emphasizes ease of maintenance. It comes with accessible components that facilitate routine servicing and upkeep, thus prolonging the lifespan of the unit and enhancing its reliability.

Furthermore, it produces minimal noise during operation, contributing to a quieter indoor environment. This feature makes it an excellent choice for residential settings where comfort and tranquility are paramount.

In summary, the Vanguard Heating VYGF33NRA stands out for its impressive heating capacity, efficiency, advanced technologies, and durable construction. Designed for versatile applications, it offers users an effective and sustainable solution for their heating needs, making it a valuable addition to any space.