Vanguard Heating VN1800ITB, VN2550ITB installation manual Heater produces unwanted odors

Page 17

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

1.

Ventilate room. Stop using odor caus-

 

 

spray, glues, etc. See IMPORTANT

 

ing products while heater is running

 

 

statement above

 

 

 

2.

Gas leak. See Warning statement at

2.

Locate and correct all leaks (see Check-

 

 

top of page

 

ing Gas Connections, page 11)

 

 

 

 

 

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 14)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 11)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove for-

 

 

and burner

 

eign matter

 

2.

Gas leak. See Warning statement at

2.

Locate and correct all leaks (see Check-

 

 

top of page

 

ing Gas Connections, page 11)

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Fresh Air for Combustion and

 

 

 

 

Ventilation requirements (page 4)

www.desatech.com

104246

17

Image 17
Contents What to do if YOU Smell GAS Infrared VENT-FREE Natural GAS HeaterVENT-FREE Natural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationLocating Heater Check GAS TypeThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Typical Inlet Pipe Diameters Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater To Select Heating Level Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat OperationInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingVENT-FREE Natural GAS Heater Heater produces unwanted odors VN1800ITB Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListVN2550ITB20 VN2550ITB Replacement Parts SpecificationsTechnical Service Service HintsEquipment Shutoff Valve GA5010 AccessoriesFloor Mounting Stand Models VN1800ITB GA4000B Models VN2550ITB GA4010BWarranty Information

VN2550ITB, VN1800ITB specifications

The Vanguard Heating VN1800ITB and VN2550ITB are high-efficiency heating solutions designed to cater to the diverse needs of residential and commercial spaces. These units exemplify advanced technology, offering reliable and consistent warmth while prioritizing energy efficiency.

The VN1800ITB model is engineered to deliver a powerful heating capacity of 18,000 BTUs, making it suitable for medium-sized rooms. It boasts a sleek design that allows for seamless integration into various decor styles. One of the standout features of the VN1800ITB is its innovative variable-speed blower, which not only enhances comfort by maintaining even temperatures but also reduces energy consumption. The blower adjusts its speed based on demand, resulting in quieter operation and improved efficiency.

In addition, the VN1800ITB includes a state-of-the-art digital thermostat that enables precise temperature control. Users can easily program heating schedules, leading to further savings on energy bills. The inclusion of a high-quality air filter improves indoor air quality by trapping dust and allergens, making it an ideal choice for households with allergy sufferers.

On the other hand, the VN2550ITB offers an impressive heating capacity of 25,000 BTUs, making it suitable for larger areas. This model incorporates similar advanced features as its counterpart, including the variable-speed blower and digital thermostat. However, it also features enhanced insulation, which minimizes heat loss and increases overall efficiency. The VN2550ITB is equipped with advanced safety features, including overheat protection and a flame rollout switch, ensuring the unit operates safely even in demanding conditions.

Both models utilize cutting-edge combustion technology that maximizes warmth while minimizing emissions. This commitment to environmental responsibility not only helps users meet local regulations but also contributes to a greener planet.

In conclusion, the Vanguard Heating VN1800ITB and VN2550ITB combine performance, efficiency, and safety features in aesthetically pleasing designs. These heating units provide dependable warmth, programmable convenience, and a commitment to indoor air quality, making them a smart investment for those seeking effective heating solutions.