Vanguard Heating VN2550ITB, VN1800ITB VENT-FREE Natural GAS Heater, Safety Information

Page 2

®

VENT-FREE NATURAL GAS HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will re- main hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department

3.This heater shall not be installed in a bedroom or bathroom.

4.Always run heater with plaque control knob at the 1, 2, 3, or 4 locked posi- tions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

5.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

6.Keep all air openings in front and bot- tom of heater clear and free of debris. This will insure enough air for proper combustion.

7.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

8.Before using furniture polish, wax, car- pet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

9.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

10.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

11.Turn off and unplug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

12.Operating heater above elevations of 4,500 feet could cause pilot outage.

2

104246

Image 2
Contents Infrared VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information VENT-FREE Natural GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Check GAS TypeInstalling Heater to Wall Thermostat Sensing BulbPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Connecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting ProcedureTo Select Heating Level Thermostat OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyVENT-FREE Natural GAS Heater Heater produces unwanted odors Illustrated Parts Breakdown VN1800ITBParts List KEY Part Number Description QTYVN2550ITB20 VN2550ITB Technical Service SpecificationsReplacement Parts Service HintsFloor Mounting Stand AccessoriesEquipment Shutoff Valve GA5010 Models VN1800ITB GA4000B Models VN2550ITB GA4010BWarranty Information

VN2550ITB, VN1800ITB specifications

The Vanguard Heating VN1800ITB and VN2550ITB are high-efficiency heating solutions designed to cater to the diverse needs of residential and commercial spaces. These units exemplify advanced technology, offering reliable and consistent warmth while prioritizing energy efficiency.

The VN1800ITB model is engineered to deliver a powerful heating capacity of 18,000 BTUs, making it suitable for medium-sized rooms. It boasts a sleek design that allows for seamless integration into various decor styles. One of the standout features of the VN1800ITB is its innovative variable-speed blower, which not only enhances comfort by maintaining even temperatures but also reduces energy consumption. The blower adjusts its speed based on demand, resulting in quieter operation and improved efficiency.

In addition, the VN1800ITB includes a state-of-the-art digital thermostat that enables precise temperature control. Users can easily program heating schedules, leading to further savings on energy bills. The inclusion of a high-quality air filter improves indoor air quality by trapping dust and allergens, making it an ideal choice for households with allergy sufferers.

On the other hand, the VN2550ITB offers an impressive heating capacity of 25,000 BTUs, making it suitable for larger areas. This model incorporates similar advanced features as its counterpart, including the variable-speed blower and digital thermostat. However, it also features enhanced insulation, which minimizes heat loss and increases overall efficiency. The VN2550ITB is equipped with advanced safety features, including overheat protection and a flame rollout switch, ensuring the unit operates safely even in demanding conditions.

Both models utilize cutting-edge combustion technology that maximizes warmth while minimizing emissions. This commitment to environmental responsibility not only helps users meet local regulations but also contributes to a greener planet.

In conclusion, the Vanguard Heating VN1800ITB and VN2550ITB combine performance, efficiency, and safety features in aesthetically pleasing designs. These heating units provide dependable warmth, programmable convenience, and a commitment to indoor air quality, making them a smart investment for those seeking effective heating solutions.