Vanguard Heating VN2550ITB, VN1800ITB Ventilation AIR, Ventilation Air From Inside Building

Page 6

®

VENT-FREE NATURAL GAS HEATER

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Outlet Air

Inlet

Air

Ventilated

Outlet Attic

Air

To Attic

To

Crawl

Space

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

6

104246

Image 6
Contents Infrared VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information VENT-FREE Natural GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeInstalling Heater to Wall Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureTo Select Heating Level Thermostat OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyVENT-FREE Natural GAS Heater Heater produces unwanted odors Illustrated Parts Breakdown VN1800ITBParts List KEY Part Number Description QTYVN2550ITB20 VN2550ITB Technical Service SpecificationsReplacement Parts Service HintsFloor Mounting Stand AccessoriesEquipment Shutoff Valve GA5010 Models VN1800ITB GA4000B Models VN2550ITB GA4010BWarranty Information

VN2550ITB, VN1800ITB specifications

The Vanguard Heating VN1800ITB and VN2550ITB are high-efficiency heating solutions designed to cater to the diverse needs of residential and commercial spaces. These units exemplify advanced technology, offering reliable and consistent warmth while prioritizing energy efficiency.

The VN1800ITB model is engineered to deliver a powerful heating capacity of 18,000 BTUs, making it suitable for medium-sized rooms. It boasts a sleek design that allows for seamless integration into various decor styles. One of the standout features of the VN1800ITB is its innovative variable-speed blower, which not only enhances comfort by maintaining even temperatures but also reduces energy consumption. The blower adjusts its speed based on demand, resulting in quieter operation and improved efficiency.

In addition, the VN1800ITB includes a state-of-the-art digital thermostat that enables precise temperature control. Users can easily program heating schedules, leading to further savings on energy bills. The inclusion of a high-quality air filter improves indoor air quality by trapping dust and allergens, making it an ideal choice for households with allergy sufferers.

On the other hand, the VN2550ITB offers an impressive heating capacity of 25,000 BTUs, making it suitable for larger areas. This model incorporates similar advanced features as its counterpart, including the variable-speed blower and digital thermostat. However, it also features enhanced insulation, which minimizes heat loss and increases overall efficiency. The VN2550ITB is equipped with advanced safety features, including overheat protection and a flame rollout switch, ensuring the unit operates safely even in demanding conditions.

Both models utilize cutting-edge combustion technology that maximizes warmth while minimizing emissions. This commitment to environmental responsibility not only helps users meet local regulations but also contributes to a greener planet.

In conclusion, the Vanguard Heating VN1800ITB and VN2550ITB combine performance, efficiency, and safety features in aesthetically pleasing designs. These heating units provide dependable warmth, programmable convenience, and a commitment to indoor air quality, making them a smart investment for those seeking effective heating solutions.