Vanguard Heating VGP30B installation manual VP2000BB

Page 31

VP2000BB

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

098304-01

Screw, #10 x 3/8"

2

2

098742-13

Front Panel

1

3

098197-03

Grill Guard

1

4

098342-01

Grill Guard Clip

2

5

098533-01AA

Bottom Glass Retainer

1

6

098260-01

Glass Panel

1

7

098532-01AA

Top Glass Retainer

1

8

M11084-26

Screw, #10 x 3/8"

4

9

098352-01BR

Deflector Unit

1

10

098271-03

Ignitor Cable

1

11

098249-01

Nut, M5

2

12

099059-04

ODS/Pilot Assembly

1

12-1

098514-01

Thermocouple

1

12-2

098594-01

Ignitor Electrode

1

13

099120-02

Burner

1

14

099387-05

3/16" Pilot Tubing

1

15

098251-01

Injector

1

16

098250-01

Injector Holder

1

17

098867-06

Pressure Regulator

1

18

099553-01

Pilot Shield

1

19

100091-01

3/8" Outlet (Burner) Tubing

1

20

100092-01

3/8" Inlet Tubing

1

21

100068-01

Pressure Tap Fitting

1

22

100047-04

Control Valve

1

23

098529-01

Cabinet

1

24

097159-02

Piezo Ignitor

1

25

M11084-26

Screw, #10 x 3/8"

2

26

M11084-38

Screw, #8 x 3/8"

2

27

098276-01

1/8" NPT Plug

1

28

098354-01

Control Knob

1

29

098508-01

Valve Retainer Nut

1

30

099066-01

Mounting Bracket

1

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

098306-02

099491-07

Control Position Decal Operating Instructions Decal

1

1

31

100100

Image 31
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRCheck GAS Type Installation ItemsLocating Heater Floor CeilingVP2000BB Methods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections ConnectingPressure Testing GAS Supply Piping System To GAS SupplyManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingControl knob and turn counterclockwise C-clockwise Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingObserved Possible Problem Cause Remedy ODS/PILOT and BurnerObserved Possible Remedy Problem Cause Trouble ShootingFrom TROUBLE- ShootingTop Ing statement atService Hints Technical ServiceVGP30B Parts Under Warranty Replacement PartsParts Not Under Warranty Manual Shutoff AccessoriesFloor Mounting Stand GA4000B ODS/Pilot KEY Part Number Description QTY VGP30B Parts List12-2 12-1 VP2000BB Limited Warranty Vanguard VENT-FREE Heaters Warranty Information

VGP30B, VP2000BB specifications

The Vanguard Heating VGP30B and VP2000BB are remarkable units designed to provide efficient, reliable heating solutions for various environments. With a focus on performance, durability, and user convenience, both models are engineered to meet a range of heating needs for residential and commercial applications.

The Vanguard VGP30B features advanced combustion technology that ensures optimal fuel efficiency and reduced emissions. This model operates on propane or natural gas, which allows for flexible installation options. The heat output ranges from 30,000 to 100,000 BTU, making it suitable for larger spaces while still maintaining a compact design. One of its standout features is the intuitive control system, which includes a programmable thermostat for easy temperature regulation and energy management.

Additionally, the VGP30B is built with a durable steel construction that enhances its longevity and performance. This model includes a built-in safety shutoff mechanism that provides peace of mind by ensuring the heater operates safely. The easy-access design not only simplifies maintenance but also minimizes downtime, making it a favorite among professional installers.

On the other hand, the VP2000BB is specifically designed for larger areas, with an impressive heating capacity of up to 200,000 BTU. This model is equipped with multiple heat output settings, allowing users to customize warmth according to their specific needs. The VP2000BB uses state-of-the-art infrared heating technology that effectively warms objects and surfaces in the room rather than merely heating the air, resulting in a comfortable and consistent heat distribution.

A key benefit of the VP2000BB is its energy-efficient design, which helps reduce heating costs over time. Its built-in fan system enhances heat circulation, ensuring that even the farthest corners of an area receive adequate warmth. The robust construction and weather-resistant materials also make this unit ideal for outdoor applications, such as workshops or temporary outdoor gatherings.

In summary, both the Vanguard VGP30B and VP2000BB encapsulate the brand's commitment to quality, energy efficiency, and user-friendly features. Whether for residential or industrial use, these heaters provide reliable performance that can be tailored to meet individual heating requirements. With their advanced technologies and durable design, they are excellent choices for ensuring a warm and comfortable environment.