Aube Technologies TH146-N-DE manual Operation, User’s Guide

Page 7

 

 

 

TH146-N-DE

 

 

 

 

User’s Guide

 

 

Non-programmable Heat Pump Controller

Emergency heat

Dual-energy

 

Appears when the

System fault mode

mode

 

temperature setpoint

 

 

 

is displayed

 

 

 

Auxiliary heat is On

 

Indoor temperature

 

 

Heating is On

 

 

 

 

Outdoor

System operating

Fan operating

Cooling is On

 

 

temperature or

 

 

mode selection

mode selection

 

 

indoor humidity

 

 

Fan is in continuous mode

 

System

 

 

 

 

operating mode

Temperature adjustment

 

 

Unoccupied

Humidifier

 

 

mode is On

is On

 

 

 

5. Operation

5.1 System Operating Mode (Heating/Cooling)

Press MODE to place the controller in one of the following modes.

HEAT

The system is in heating mode.

 

 

 

COOL

The system is in cooling mode.

 

 

 

AUTO

The system is in automatic changeover. (The system

switches between heating mode and cooling mode to main-

 

 

tain the desired temperature.)

OFF

Both heating or cooling are off.

 

 

 

EHEAT

The system is in emergency heat mode. Only auxiliary heat-

ing is used when there is a call for heat.

 

 

5.2

 

 

 

Fan Operating Mode (On/Auto)

Press the button to select the fan operating mode.

In automatic mode, the fan runs only when heating or cooling is activated.

In continuous mode, the fan runs continuously and the sym- bol is displayed. NOTE: If the “smart fan” feature is enabled, the fan will run only when heating or cooling will be activated during unoccupied mode.

5.3 Indoor Humidity / Outdoor Temperature Display

Depending on how the controller has been configured (see page 4, item 9), it displays either the measured indoor humidity level or the measured outdoor temperature.

Outdoor

 

 

 

 

 

 

 

Indoor

 

 

 

temperature

 

 

 

 

 

 

 

 

 

humidity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.4 Temperature Adjustment

The actual (measured) temperature is normally displayed. To view

the temperature setpoint, press one of the buttons once. The setpoint is displayed for 5 seconds and is indicated by the sym- bol.

To modify the temperature setpoint, press one of the buttons until the desired temperature is displayed.

NOTE: If the controller is in automatic heat/cool changeover, the setpoint is automatically reduced or raised by 1°C (2°F) when the controller switches to heating mode or to cooling mode respectively. For example, if you place the setpoint at 24°C (75°F) while in heat- ing mode, the setpoint will become 25°C (77°F) in cooling mode and will return to 24°C (75°F) when the controller switches back to heat- ing mode.

5.5 Humidity Adjustment

The humidity adjustment can be placed in manual mode or in auto- matic mode (see page 4, item 11).

Manual Adjustment

In manual mode, the user sets the humidity level (5% to 60%).

Automatic Adjustment

In automatic mode, the controller sets the humidity level based on the outdoor temperature to prevent ice formation or condensation on windows. However, the user can apply an offset (-9% to 9%). For example, the user can enter a negative offset if there is too much condensation on the windows.

Procedure

The procedure to set the humidity level (in manual mode) or the off- set (in automatic mode) is as follows:

1)Press the Mode button for 3 seconds. One of the following displays appears:

TH146-N-DE

400-280-000-G

9/22/06

7/8

Image 7
Contents Installation Guide InstallationIntroduction Configuration Principles of Operation Parameters Display Options Default Description Configuration MenuConnection Diagram New Installation Connection Diagram Add-on Installation User’s Guide OperationSupport Technical SpecificationsWarranty Unoccupied Mode