Amcor PCMA 15KE-410, PCMA 12KE-410, PCMA 9KE-410 user manual Storage, Trouble Shooting

Page 13

GB

STORAGE

Empty the internal water container.

Clean the screen filter.

Remove the active carbon filter before end of season storage and install new filters at the beginning of the new season.

The old filters can be disposed of in the ‘Non-biological rubbish container’.

Replacement filter packages are available from Amcor.

Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry.

Store the cable as shown.

Protect the unit against dust and store in a dry place, not accessible to children.

TROUBLE SHOOTING

Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property.

Problem

Cause

Solution

 

 

 

The air

No power supply.

Connect to a functioning outlet and switch on.

conditioner does

Is the LCD light flashing.

Empty the internal water container.

not function.

Timer function is active.

Deactivate TIMER function.

The air

In direct sunlight.

Close curtains.

conditioner does

Windows or doors open, many

Close doors and windows, place an extra air

not seem to

people or a heat source in the room.

conditioner.

perform.

Dirty filter.

Clean or replace the filter(s).

 

Air inlet or air outlet blocked.

Remove the blockage.

 

Room temperature lower than the

Change temperature selection.

 

selected value.

 

The unit is noisy.

Unit stands uneven.

Place on an even, solid surface (less

 

 

vibrations).

The compressor

The overheat protection is probably

Wait 3 minutes until the temperature has

does not work.

activated.

decreased, then turn on the unit again.

The remote

Distance too great.

Make sure the remote control is correctly

control does not

Remote control signal not detected

aimed at the control panel.

function.

by the control panel.

 

 

The batteries are drained.

Replace the batteries.

To correct problems that have not been described in the table and/or if the recommended solutions fail to solve the problem, contact an authorized service centre.

13

Image 13
Contents Portable AIR Conditioner Thank YOU Safety InstructionsOverloaded Damaged Chemicals Parts Display Control PanelDoing so keep this in mind InstallationOperation Programming the timer for OFF when the unit is Running Programming the timer for on when the unit is OFFCancelling the timer function LCD blue back lightAir flow Sleep modeDehumidification Remote Control Filter installation Cleaning the air filtersAIR Filters Screen filter must always be usedEmptying the Internal Water Container CleaningContinuous Drainage Storage Trouble ShootingPcma Technical DataHong Kong

PCMA 15KE-410, PCMA 12KE-410, PCMA 9KE-410 specifications

Amcor, a global leader in packaging solutions, has developed a range of advanced polypropylene container technologies, including the PCMA 12KE-410, PCMA 9KE-410, and PCMA 15KE-410. These innovative products are designed to meet the demanding needs of various industries, ensuring product safety, extended shelf life, and enhanced user convenience.

The PCMA 12KE-410 is engineered for flexibility and durability, making it ideal for a wide array of applications, from food to pharmaceuticals. Its design incorporates a robust polypropylene structure that provides excellent resistance to bending and impact. One of the key features of PCMA 12KE-410 is its enhanced sealing technology, which minimizes the risk of contamination and leakage. This is crucial for maintaining product integrity and safety, particularly in food packaging.

Next in the lineup, the PCMA 9KE-410 is characterized by its lightweight design without compromising strength. This container is an example of Amcor’s commitment to sustainability, as it uses less material than traditional containers while still offering exceptional performance. The 9KE-410 model features a unique airflow design that aids in the cooling of products, making it especially suitable for perishable goods. It boasts user-friendly features such as an easy-open lid, which enhances consumer experience while maintaining secure closure.

Finally, the PCMA 15KE-410 provides an impressive capacity for larger quantities, catering specifically to bulk packaging needs. Its strong, rigid design ensures stability during transportation and storage. This model integrates advanced barrier technologies that prevent gas and moisture from entering, thereby preserving the quality of the contents. With its ergonomic design, the 15KE-410 also enables easier handling, further increasing its practicality in various settings.

Overall, Amcor’s PCMA series—12KE-410, 9KE-410, and 15KE-410—showcases the company’s dedication to innovation in packaging technology. From build quality to user experience and sustainability, these containers illustrate a comprehensive understanding of market needs. By marrying functionality with modern design, Amcor continues to lead in the packaging sector, providing solutions that meet both consumer demands and environmental responsibilities.