Listen Technologies LR-500, LR-300 manual LR-400 Specifications, Specification LR-400-072 LR-400-216

Page 27

LR-400 Specifications

Architectural Specifications

The FM receiver shall be capable of receiving on 57 wide and narrow band channels with a SNR of 80dB or greater. The receiver shall be capable of seeking channels. The device shall have an adjustable squelch. The device shall have an audio frequency response of 63 Hz to 15 KHz, ± 3dB at 72 MHz, or of 63 Hz to 10 kHz, ± 3dB at 216 MHz. The device will incorporate a stereo headset jack that allows the user to plug in either a mono or stereo headset and listen to the audio normally. The device shall incorporate an LCD display that indicates channel, battery level, low battery, battery charging, RF signal strength and channel lock status. The receiver shall incorporate automatic battery charging circuitry for recharging of NiMH batteries. The Listen LR-400 is specified.

Specifications

 

 

Specification

 

LR-400-072

LR-400-216

 

 

RF Frequency Range

 

72.025-75.950 MHz

216.025-216.975 MHz

 

 

Number of Channels

 

57 (17 wide, 40 narrow)

57 (19 wide, 38 narrow)

 

 

Sensitivity

 

.6uV typical, 1 uV maximum for 12dB SINAD

 

RF

Frequency Accuracy

 

± .005% stability 32 to 122º F (0 to 50º C)

 

Antenna

 

Uses earphone cable

 

 

 

 

 

 

 

Antenna Connector

 

3.5 mm connector

 

 

 

Squelch

 

Programmable in 20 steps

 

 

 

Compliance

 

FCC Part 15, Industry Canada

 

 

 

 

 

 

 

 

** All system specifications are wireless end-to-end

 

 

System Frequency Response

 

63 Hz-15 Hz (±3dB)

63 Hz-10 kHz (±3dB)

 

 

System Signal to Noise Ratio (A-weighted)

SQ™ enabled: 80dB;

SQ™ enabled: 80dB;

 

Audio

 

 

SQ™ disabled: 60dB

SQ™ disabled: 50dB

 

System Distortion

 

< 2% total harmonic distortion (THD) at 80% deviation

 

 

 

 

 

Output

 

3.5 mm connectors, unbalanced, 0dBu nomial output level, 16mW maximum,

 

 

 

impedance 32 Ohms

 

 

 

 

 

 

 

 

 

 

 

 

Set Up Controls

Alkaline/NiMH batteries and SQ™ enable/disable and programmable squelch setting

 

 

User Controls

Volume, channel UP/DOWN/SEEK (All controls except volume are electronically

 

Controls

lockable, and are behind the door)

 

 

 

 

 

 

Squelch can be adjusted for sensitivity and signal capture control. Channel selection

 

 

 

 

 

Programming

can be locked by holding the SEEK button for 5 seconds. Unit cannot be programmed

 

 

 

to seek only used channels, however, it is capable of entering squelch mode.

 

 

 

 

 

 

LCD Display

Indicates channel, RF signal strength, lock status, and squelch setting

 

Indicators

LED

Red, illuminates when unit is on. Flashes when batteries are low. Flashes when charg-

 

 

ing. Flashes when locked and user attempts to seek to another channel.

 

 

 

 

 

 

 

 

 

 

Battery Type

Two AA batteries, alkaline or NiMH

 

 

 

Battery Life (Listen batteries)

30 hours alkaline (LA-361), 15 hours NiMH rechargeable (LA-362)

 

Power

Battery Charging (NiMH only)

Fully automatic, 14 hours

 

 

Power Supply Connector

2.3 mm OD by 0.7 mm ID, barrel type connector. 7.5VDC, center positive <250mA.

 

 

 

 

Drop in contact points for use with Listen charging/carrying cases

 

 

 

 

 

Compliance

UL Listed

 

 

 

 

 

 

 

 

Dimensions W x D x H

3.0 x 1.0 x 4.25 in. (7.6 x 2.5 x 13 cm)

 

 

 

Unit Weight

3.9 oz. (111 g)

 

 

Physical

Unit Weight with batteries

5.8 oz. (164.4 g)

 

 

 

Shipping Weight

1.0 lbs. (453.6 kg)

 

 

 

Door

Manually lockable. UP, DOWN and SEEK protected by door

 

 

 

 

 

 

 

Temperature - Operation

14 to 104º F (10 to 40º C)

 

 

Environmental

Temperature - Storage

-4 to 122º F (-20 to 50º C)

 

 

 

Humidity

0 to 95% relative humidity, non-condensing

 

LR-400

23

Image 27 Contents
Page Page Page Page Receivers Table of Contents Page Page Page LR-500 Table of Contents LR-500 Package Contents Architectural Specifications LR-500 SpecificationsLR-500 Quick Reference Battery CompartmentRemove the product LR-500 Setup InstructionsSelect Channels Make Sure the Unit is On LR-500 Operation InstructionsTo Lock into Only One Channel Locking Out Unwanted Channels LR-500 Programming InstructionsSquelch Programming Instructions LR-500 SquelchLR-500 Charging Batteries LR-500 Wall Transformer Operation Page Page Page Page LR-400 Table of Contents LR-400 Package Contents Specification LR-400-072 LR-400-216 LR-400 SpecificationsLR-400 Quick Reference LR-400 Setup Instructions See page 29 for squelch and programming information LR-400 Operation Instructions To Lock into Only One Channel LR-400 Squelch LR-400 Charging Batteries LR-400 Wall Transformer Operation Page Page Page LR-300 Table of Contents LR-300 Package Contents Specification LR-300-072 LR-300 SpecificationsLR-300 Quick Reference LR-300 Setup Instructions Red LED will illuminate when on Earphone/Headset jack LR-300 Operation Instructions LR-300 Charging Batteries LR-300 Wall Transformer Operation Channel Selection SQ Summary Listen SQRF Reception Maximization Strategies Comtek Williams Gentner Telex Drake MHz Compatibility ChartCSI AVR Troubleshooting Troubleshooting LR-300, LR-400, LR-500 ReceiversUsers keep changing channels TroubleshootingCompliance Notice Compliance Notice and FCC StatementWarranty Warranty & Contacting ListenEarphone Options Optional AccessoriesPage