Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer.

Installing the Firestop Spacer

in the Ceiling Hole

A firestop spacer is used to keep pipe spaced properly and required for safety.

Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.

Hole sizes listed in Figure 13 for angled firestop spacers provide minimum required air space to chim- ney pipe for ceiling thickness up to 8" (203mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8" (203mm), adjustments must be made in framing to assure that minimum air spaces to chimney are maintained.

Pipe Section

Pipe

Rim

Hem

Lance

Pipe

Rim

FP558

Fig. 16 Install pipe, listening for the snap-lock to fasten.

Proper Firestop Spacer Installation

Figure 18 shows different installation procedures for both an area that is an attic and an area that is not an attic.

If the area above the ceiling is not an attic, position the firestop spacer with the flange on the ceiling side and the angled portion extending up into the hole.

If the area above the ceiling is an attic, position the firestop spacer with the flange on the top of the framed hole and the angled portion extending down into the hole.

Firestop spacers are not available for nor are they required on vertical walls.

DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you seal this area, it may cause a fire hazard.

Elbow Strap

Angled Strap

FP270/271

Support Structure

Elbow Strap (must be tight)

Ceiling Hole

Framing

Angle Firestop

Chimney Support Strap (must be tight)

Canadian Requirements

Fig. 17 Attach straps to a structural framing member.

 

for Insulation Shield

 

In Canada, an attic

Attic Installation

Ceiling Installation

insulation shield is

 

 

 

required to prevent attic

 

 

Nails (4)

insulation from contact-

 

 

 

 

Joist

ing the chimney sec-

 

 

 

 

Firestop

tion. Framing dimen-

 

 

 

 

Spacer

sions for the chimney

 

 

 

hole should measure

 

 

Firestop

14¹⁄₂" x 14¹⁄₂" (368 x

 

 

Spacer

 

 

Joist

368mm). An attic shield

 

 

 

 

 

MUST be installed on

 

 

 

top of attic joists (above

 

 

Nails (4)

the floor level). (Fig.

 

 

 

 

FP593

19)

 

 

Fig. 18

Installing firestop spacer.

 

 

 

12

 

 

7412948

Image 12
Contents SR/SC Series a Safety Information Table of ContentsSR36A Series Woodburning Fireplace SR42A Series Woodburning Fireplace Chase Installation Chimney Requirements Offset Installations Installed lengths of chimney sections Planning InformationMounting The Fireplace Planning the Chimney RunInstallation Chase InstallationChimney Supports Insulating Fireplace Enclosure for Cold ClimatesInstalling Electrical Wire For Circulator Models Install Fan Kit AssemblyChimney Setup FramingStraight-Up Chimney Installation Offset InstallationCeiling Chimney Hole Possible Obstructions Cutting the HolePositioning, Safety Strips Securing the Fireplace Installing Outside Air KitInstalling the Chimney System Angle of Chimney at CeilingInstalling the Firestop Spacer Ceiling Hole Proper Firestop Spacer InstallationCanadian Requirements For Insulation ShieldContinue Installing Pipe to Complete Run Install Remainder of Chimney SectionsAdditional Ceilings Penetrating the RoofInstalling Top Housing or Termination Installing Chimney In a ChaseFinishing Finish Wall Front View Side ViewTop View Mantel clearancesSide Wall Protection Hearth Installation Noncombustible Surround FacingCommon Materials and Factors Installing Line for Gas Logs Fireplace Top ViewItem/Model Number 948Accessories Accessory Description Model NumberChimney Components Component Description Model NumberChimney Components cont. Canada Limited Warranty & 30 Year Protection Plan CFM Specialty Home Products